Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  superizolacja
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
EN
The development of innovative materials aiming to achieve energy savings is a main focus in the building technology sector. In this regard, aerogel-enhanced products are often indicated as promising materials for achieving high thermal resistance in the building envelope. This paper aims to review the current state of the art of the aerogel-enhanced opaque systems. Cement-based products are reviewed as well as aerogel-enhanced renders and plasters. The focuses moves also on aerogel-enhanced blankets, which are among the most promising superinsulating systems. Comparative thermal characterization tests of several aerogel-enhanced blankets confirm their superior performance with a thermal conductivity as low as 0.010 W/(mK). Finally, future research challenges for making aerogel-enhanced products more common in buildings are presented.
PL
Jednym z głównych celów obecnie opracowanych innowacyjnych materiałów jest uzyskanie oszczędności energii. W związku z tym, produkty wzbogacone aerożelem są wskazywane jako obiecujące materiały, pozwalające na osiągnięcie dużego oporu termicznego zewnętrznych przegród budynków. W artykule dokonano przeglądu obecnie stosowanych systemów izolacyjnych przegród nieprzezroczystych wzbogaconych aerożelem. Zaprezentowano przegląd materiałów na bazie cementu, a także ulepszone przy użyciu aerożelu materiały wykończeniowe. Skupiono się też na ulepszonych przy użyciu aerożelu matach izolacyjnych, które należą do najbardziej obiecujących systemów superizolacji. Porównawcze badania charakterystyki termicznej kilku mat wzbogaconych aerożelem potwierdzają ich doskonałe właściwości i przewodność cieplną wynoszącą ok. 0,010 W/(mK). Na zakończenie zaprezentowano wyzwania badawcze związane z upowszechnieniem w budownictwie produktów wzbogaconych aerożelem.
PL
Przedstawiono budowę kriogenicznej wielowarstwowej izolacji próżniowej - superizolacji. Opisano mechanizm przenikania ciepła przez taką izolację uwzględniając przewodzenie ciepła przez gaz resztkowy, przewodzenie ciepła przez ciało stałe oraz promieniowanie. Zaproponowano model matematyczny umożliwiający określenie ilości ciepła przenikającego przez izolację w zależności od ilości warstw ekranów radiacyjnych, miejsca ich ułożenia oraz ciśnienia gazu resztkowego. Po eksperymentalnej weryfikacji modelu przeprowadzono badania symulacyjne pozwalające na optymalizację wykonania superizolacji ze względu na ilość warstw, ciśnienie gazu resztkowego, przedział temperatur i położenie izolacji.
EN
A thermodynamic analysis of different insulation systems used in refrigeration and cryogenic devices and installations is presented. A concept of cryogenic multilayer vacuum insulation (superinsulation) is described. The total heat flux between the layers is the result of three distinct heat transfer modes: radiation, residual gas conduction and solid spacer conduction. A mathematical model describing the heat flux through cryogenic multilayer insulation has been developed and experimentally verified. The model enables the optimization of the insulation with regard to different MLI parameters, such as residual gas pressure, number of layers, boundary temperatures and location of the insulation layers in the vacuum space. Different configurations of the above parameters are analyzed and optimal solutions found.
PL
W pracy przedstawiono model umożliwiający określenie rozkładu temperatur w superizolacji oraz określenie dopływów ciepła do ciekłego azotu przesyłanego rurociągiem próżniowym. Model został opracowany w związku ze stanowiskiem badawczym, które jest budowane w Zakładzie Chłodnictwa i Kriogeniki Politechniki Wrocławskiej. Przyjęty model uwzględnia trzy mechanizmy przekazywania ciepła tj. przewodzenie przez gaz resztkowy, przewodzenie przez izolację oraz promieniowanie. Do obliczeń opracowano program w Turbo Pascalu z możliwością obróbki danych w skoroszycie Exel.
EN
The article deals with theoretical model applied to compute the temperature distribution across the Multilayer Insulation and heat flux to the liquid Nitrogen. The model considers the heat transfer by thermal radiation, solid conduction through the separator material and gas conduction. Each mode is treated separately and then combined into one equation is used in numerical calculations. Turbo Pascal 7 and Exel was employed to accomplish those calculations. The results show that there is strong relationship between heat flux and the pressure above 0.001 Pa. Below that value the heat flux remains constant. The results also show that there is no point in increasing layers of MLI, up to 20 the changes in heat flux are remarkably. First layers are responsible for reducing the heat getting into the system. Further increases in layers causes slight changes in heat flux. Thus, with good 0.5 W/m2 with respect to inner tube surface. There are also shown the thermal results of MLI without spacer (flouting MLI). The heat flow is of one order of magnitude less than in the case of MLI with spacer.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.