EN
The article presents the results that can be a prerequisite for the introduction of a pre-sowing electrotreatment of winter rape seeds into the production process. The results of photon emission by rape seeds after electrical stimulation are highly correlated with the data obtained during determination of its sowing qualities and field germination. Absorption and transformation of the energy of the external electric field during the electrostimulation of winter rape seeds occurs non-linearly. It was established that the main transformations take place during the first 15 s, regardless of the electric field intensity. Relaxation processes were revealed, which become dominant after 15 s of electrical stimulation. The pre-sowing electrical stimulation improved the sowing properties of winter rapeseed. The highest values of germination energy and laboratory germination (87% and 96%), which exceeded the control by 9% and 8%, were obtained under the treatment mode E=2 kV⸱cm-1 , t=30 s. Pre-sowing electrostimulation of winter rape seeds at optimal conditions helps to increase its field germination. Under the treatment mode E=2 kV⸱cm-1 , t=30 s was 90%, and with E=3 kV⸱cm-1 , t=30 s - 83% versus 79.7% in the control.
PL
Niniejszy artykuł przedstawia wyniki, które mogą stanowić przesłankę wprowadzenia przedsiewnego zabiegu elektrycznego nasion rzepaku ozimego w procesie produkcji. Wyniki emisji fotonu przez nasiona rzepaku po elektrycznej stymulacji są powiązane mocno z danymi otrzymanymi podczas określania ich właściwości siewnych oraz kiełkowania. Absorpcja oraz transformacja energii zewnętrznego pola elektrycznego podczas elektrostymulacji nasion rzepaku ozimego występuje nieliniowo. Stwierdzono, że główne transformacje mają miejsce w pierwszych 15 sekundach bez względu na intensywność pola elektrycznego. Odkryto procesy relaksacyjne, które stały się dominujące po 15 sekundach stymulacji elektrycznej. Przedsiewna stymulacja elektryczna poprawiła właściwości siewne rzepaku ozimego. Najwyższe wartości energii kiełkowania i kiełkowania laboratoryjnego (87% i 96%) co przekroczyło próbę o 9% i 8%, uzyskano w trybie zabiegu E = 2 kV⸱cm-1 , t = 30 s. Elektrostymulacja przedsiewna nasion rzepaku ozimego przy optymalnych warunkach pomaga zwiększyć kiełkowanie na polu. W trybie zabiegu E = kV⸱cm-1 , t = 30 s wynosiło 90%, a przy E = 3 kV⸱cm-1 , t = 30 s - 83% versus 79.7% w próbie.
EN
The samples of rapeseed oil obtained by dissolving ground rapeseed in hexane (chemical extraction method) were studied. Portion of sample seeds was left unthreatened as the reference, another was treated by an electrostatic field at intensity of E = (0,5 ÷ 2,5) kV/cm and t = 30c. The behavior of fluorophores of solutions of rapeseed oil in hexane, namely, tocopherol, phenol, fatty acids, vitamins and pigments provided information on the chemical composition and cell structure of the studied seeds. It was established that the fluorophores of solutions of rapeseed oil in hexane prepared from unthreatened seeds and seeds treated at an electrostatic field intensity of E = (0,5 ÷ 2,5) kV/cm and t = 30c are characterized by identical spectral-luminescent properties. The spectral-luminescent properties of phenols, tocopherols, fatty acids, vitamins and pigments of rapeseed oil obtained from the untreated and treated seed, were identical, regardless of the modes of its pre-sowing treatment. Presowing electric treatment of rapeseed by an electrostatic field in this mode does not cause changes in the chemical composition and structure of the cell, its fatty acid composition and the content of vitamins and pigments.
PL
Badano próbki oleju rzepakowego otrzymanego przez rozpuszczenie zmielonych nasion rzepaku w heksanie (metoda ekstrakcji chemicznej). Część próbek nasion pozostawiono bez naprężeń jako referencyjną, inną poddano działaniu pola elektrostatycznego o natężeniu E = (0,5 ÷ 2,5) kV/cm i t = 30c. Zachowanie się fluoroforów roztworów oleju rzepakowego w heksanie, tj. tokoferolu, fenolu, kwasów tłuszczowych, witamin i pigmentów dostarczyło informacji o składzie chemicznym i budowie komórkowej badanych nasion. Ustalono, że fluorofory roztworów oleju rzepakowego w heksanie sporządzonych z nasion niezagrożonych i nasion traktowanych polem elektrostatycznym o natężeniu E = (0,5 ÷ 2,5) kV/cm i t = 30c charakteryzują się identycznymi właściwościami spektralno-luminescencyjnymi. Właściwości spektralno-luminescencyjne fenoli, tokoferoli, kwasów tłuszczowych, witamin i barwników oleju rzepakowego uzyskanego z nasion nietraktowanych i traktowanych elektrycznie były identyczne, niezależnie od sposobu ich przedsiewnej obróbki. Przedsiewna obróbka elektryczna nasion rzepaku polem elektrostatycznym w tym trybie nie powoduje zmian w składzie chemicznym i strukturze komórki, składzie kwasów tłuszczowych oraz zawartości witamin i barwników.
PL
W artykule dokonano przeglądu elektronicznych układów stymulacyjnych stosowanych do elektrycznej stymulacji komórek nerwowych. Pod uwagę brane były krytyczne parametry tych bloków w kontekście ich planowanej implementacji w wielokanałowym układzie scalonym. Są to m.in. rozrzuty prądów stymulacyjnych, pobór mocy tych układów, stopień komplikacji układowej czy też zajętość powierzchni krzemu. Przedstawione są podstawowe parametry i wymagania dotyczące układów stymulacyjnych oraz wyniki symulacyjne trzech powszechnie stosowanych architektur zaimplementowanych w technologii CMOS 180nm.
EN
The paper presents a review of stimulation circuits dedicated to multichannel implantable electrical stimulation of large population of neuronal cells. We take into account the main requirements of such circuits, i.e. spread of generated stimulation impulses from channel to channel, power and area consumption and architecture complexity. The paper contains analysis of the main problems that may be encountered while designing current sources able to both generating currents in a broad range and satisfying requirements referring to its output resistance, low output voltage, and uniformity of generated currents. Three most popular architectures of current stimulators are taken into consideration: solution with two independently controlled positive and negative currents and two solutions where one of the currents is generated as the copy of the second one. Simulations were carried out with use of the Cadence environment and the CMOS 180nm process was taken into account. The simulation results followed by the conclusions are presented at the end of the paper.
4
Content available remote Historia zastosowania stymulacji elektrycznej w psychiatrii
PL
Od czasów prehistorycznych trwają próby wykorzystania terapeutycznego stymulacji elektrycznej - również w przypadku zaburzeń natury psychiatrycznej. Wykorzystywane były zarówno naturalne źródła (bursztyn, ryby elektryczne), jak i sztuczne źródła „elektryczności” (maszyny elektrostatyczne, stosy Wolty, butelki lejdejskie, inne generatory prądu elektrycznego). Realną skuteczność dawnych metod stymulacyjnych - niedrgawkowych - ocenić można za niewielką lub żadną. Nowoczesną epokę stosowania stymulacji elektrycznej w psychiatrii rozpoczyna wprowadzenie elektrowstrząsów EW.
EN
The efforts of therapeutic utilization of the electric stimulation (also in the case of the psychiatric disorders) last from prehistoric times. They were used both natural sources (amber, electric fish), and artificial sources „electricity” (electrostatic machines, Volt's stocks, Leyden bottles, the different generators of the electric current). The real effectiveness of former (non-convulsive) stimulation methods can be estimated as low or non. The modern epoch of applying electric stimulation in psychiatry begins by introduction of electroconvulsive therapy ECT.
EN
The aim of this study was to clarify the effects of tendinous tissue properties on origin of greater force output at short inter-pulse intervals in the 2-pulse trains compared to those at longer inter-pulse intervals. Thus, this study investigated the contributions of the second stimulus (C2) in 2-pulse trains with different inter-pulse intervals on the torque response and tendinous tissue properties of human skeletal muscle in vivo. The torque response and tendinous tissue elongation following single pulses and 2-pulse trains at different inter-pulse intervals (5, 10, 20, 30, 40, 50, 80, 100, 150, and 200 ms) were recorded in the tibialis anterior muscle using real-time ultrasonography. C2 with inter-pulse intervals of 5-100 ms invoked significantly greater torque responses than single pulses. In contrast, the elongation and compliance of tendinous tissue for C2 with inter-pulse intervals from 5-80 ms were significantly lower than those of the single-pulse response. A significant negative relationship between torque response and tendinous tissue compliance was observed in C2 with different inter-pulse intervals. The torque response as a result of C2 is greater at short inter-pulse intervals in which the force summation due to second stimulus coincides with the period of decreased tendinous tissue compliance due to the first stimulus.
6
Content available remote Problemy z placebo i ślepą próbą magnetycznej stosowanych w psychiatrii
EN
Except pharmacotherapy in treatment of various psychiatric disorders are used different physical techniques based on the electrical or magnetic stimulation of the head/brain. Confirmation of the effectiveness of the given method requires clinical investigations conducted in the blinded conditions and in the control to placebo. The paper presents difficulties connected with the assurance of these conditions in the case of chosen physical methods.
PL
Oprócz farmakoterapii w leczeniu rozmaitych zaburzeń psychiatrycznych wykorzystuje się różne techniki fizykalne polegające np. na stymulacji elektrycznej lub magnetycznej głowy/mózgu. Potwierdzenie skuteczności danej metody wymaga badań klinicznych przeprowadzonych w warunkach zaślepienia oraz w kontroli do placebo. Praca prezentuje trudności związane z zapewnieniem tych warunków właśnie w przypadku wybranych metod fizykalnych.
PL
Pierwsze doniesienia o zabiegach leczniczych wykorzystujących prąd elektryczny można znaleźć w literaturze z XIX wieku. Połączenie akupunktury z elektroterapią to elektro-akupunktura. Rozwój elektroterapii jest uwarunkowany rozwojem aparatury oraz konstrukcją elektrod. Miniaturyzacja urządzeń do terapii prądem elektrycznym pozwala na prowadzenie terapii całodobowo, a nawet wielodniowo, bez wychodzenia pacjenta z domu. Założeniem podstawowym w terapii długoterminowej jest poprawa potencjałów komórkowych i regeneracja komórek w miejscu objętym terapią. W artykule przedstawiono wybrane zagadnienia techniczne i praktyczne długoterminowej stymulacji elektrycznej.
EN
First applications of electrical current in medicine were described in a literature in 19. century. Acupuncture combined with electrotherapy is called electroacupuncture. The progress in electrotherapy relies on the development of new devices, as well as the electrodes. The miniaturization of electrostimulators enables 24-hours application. Small stimulator can be easily stored in a pocket and used when necessary. Long-term electrostimulation influences the cell potential and regeneration processes. In this paper some technical and practical aspects of long-term electrostimulation will be discussed.
8
Content available remote Realistic simulation of ECT electrodes
EN
This paper discusses numerical simulation of electroconvulsive therapy (ECT). A realistic finite element model of human head with different models of stimulating electrodes is be presented. Special attention is paid to the influence of the model of electrodes on the results of simulation.
PL
Przedstawiony niżej tekst opisuje numeryczną symulację terapii elektrowstrząsowej (EW). Przedstawiono realistyczny model MES ludzkiej głowy z różnymi modelami elektrod stymulujących. Szczególny nacisk został położony na wpływ modelu elektrod na wyniki symulacji.