Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 1

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  stub column
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Compressive performance of AFRP reinforced laminated bamboo stub columns
EN
Engineered bamboo construction can be affected by natural defects, insects, corrosion, etc., which will result in damaging the mechanical properties of structural components. However, traditional reinforcement methods such as setting steel supports and increasing the cross-sectional area of components may cost a lot and cause a negative influence on the appearance of building. Many engineering practices and research works show that applying FRP (Fiber Reinforced Polymer/Fiber) sheet is an economical and efficient method for reinforcing and retrofitting building structures. Therefore, the compressive performance of AFRP (Aramid Fiber Reinforced Polymer/Fiber) reinforced laminated bamboo lumber (LBL) stub columns was studied in this paper. Through six groups (three replicates for each group) of stub columns with six different cloth ratios, the influence of AFRP on the failure pattern and mechanical properties of bamboo columns was explored. The test results showed that AFRP could effectively restrain the lateral deformation and improve the mechanical behavior of LBL columns. With the increase in cloth ratio, the ultimate strength and elastic modulus increased linearly in general, while the Poisson’s ratio gradually decreased. The reduced modulus of reinforced columns in the elastoplastic stage increased up to 161.31% compared with normal columns. Although the ductility of LBL columns laterally wrapped by AFRP was greatly improved, the initial stiffness, yield point and turning points between elastoplastic stage and plastic stage basically remained unchanged in contrast to unreinforced columns. Based on the test results, an empirical equation considering the cloth ratio was proposed to calculate the ultimate strength of AFRP reinforced LBL columns, using ‘Lam and Teng’ model. In addition, a simplified equation was also proposed to calculate the compressive strength of reinforced LBL columns derived from Mises yield criterion. The results of this work can be a reference to promote the application of strengthening and retrofitting engineered bamboo structure with FRP.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.