Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  struktura polimerowa
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents a model describing dependence of the piezoelectric coefficient d33(p) on the pressure p applied to heterogeneous layered dielectric structures. Previous studies have shown that the d33(p) dependence for such structures may be determined by the pressure dependence of the elasticity modulus Y1(p) of a soft layer. The model is related to an elastic layer comprising a nonwoven, for which the Y1(p) dependence can be described by the deformation of individual fibers being in the mutual contact. Model analysis shows that the d33(p) dependence can be approximated by a power-type function: d33(p) = Apn . The power type of the d33(p) dependency, with power-factor -0.20 < n < -0.12 was confirmed experimentally.
PL
W pracy przedstawiono model opisujący zależność współczynnika piezoelektrycznego d33(p) od przyłożonego ciśnienia p dla niejednorodnych dielektrycznych struktur warstwowych. Wcześniejsze badania wykazały, że charakter zmian d33(p) dla wymienionych struktur może być określony zależnością współczynnika sprężystości warstwy miękkiej Y1(p) od obciążenia. Przedstawiony model dotyczy struktury zawierającej warstwę elastyczną w postaci włókniny, dla której zależność współczynnika sprężystości może być opisana modelem odkształcania włókien. Analiza modelu wskazuje, że zależność d33(p) można opisać funkcją potęgową typu d33(p)=Apn. Potęgowy charakter zależności d33(p), z wartością -0.20 < n < -0.12 potwierdzono doświadczalnie.
EN
Due to lack of effective methods for preventing the complications associated with stent implantation, the search for new solutions is conducted, including those based on the use of biodegradable polymers. Such materials could allow us to develop a temporary implant that would ensure flow in the vessel until its regeneration, while minimising the negative effects connected with long--erm implant–tissue interaction. In this study, models in the form of biodegradable stents of different materials and geometry were prepared. Due to the fact that one of the basic requirements imposed on vascular stents is the ability to resist radial loads caused by the surrounding tissue, the maximum radial forces causing destruction of prepared models were investigated. The results were compared with the values obtained for commercially used metallic implants. Models were also incubated in Eagle's medium enriched with albumin in order to assess potential adhesion capacity of proteins on their surface. Scanning electron microscope enabled monitoring of microstructural changes during incubation. The results obtained were used to evaluate the ability to obtain a functional, biodegradable vascular stent.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.