PL
W pracy opisano przebieg nieniszczących badań konstrukcji podziemnego zbiornika na wodę oraz przeprowadzono analizę statyczno-wytrzymałościową. W zakres wykonanych prac wchodziła pełna inwentaryzacja obiektu, badania nieniszczące ścian i stropu zbiornika oraz analiza numeryczna pracy całego obiektu z wykorzystaniem programu opartego na MES. Określono możliwość dalszego użytkowania zbiornika.
EN
The paper describes the course of non-destructive testing of the structure of the underground water tank and the static and strength analysis performed. The scope of work included a full inventory of the facility, non-destructive testing of the walls and ceiling of the tank, and numerical analysis of the operation of the entire facility using a program based on MES. The possibility of further use of the tank was determined.
PL
Artykuł dotyczy stanu technicznego dwóch najwyższych kominów w Polsce, zlokalizowanych w Jaworznie oraz w Warszawie. Oba kominy mają konstrukcję żelbetową. Na obu obiektach przeprowadzono liczne prace diagnostyczne. Wykonywano nieniszczące i niszczące badania betonu i zbrojenia. Przeprowadzono szczegółowe oględziny z wykorzystaniem technik alpinistycznych. Określano ponadto stopień karbonatyzacji betonu. Wykonano obliczenia sprawdzające. Na podstawie uzyskanych wyników badań oraz analiz podano wytyczne dotyczące dalszej eksploatacji.
EN
The article concerns the technical condition of the two highest chimneys in Poland, located in Jaworzno and Warsaw. Both chimneys have a reinforced concrete structure. Numerous diagnostic works were carried out on both sites. Non-destructive and destructive tests of concrete and reinforcement were performed. A detailed inspection was carried out with the use of mountaineering techniques. Moreover, the degree of concrete carbonation was determined. Verification calculations were made. Based on the obtained test results and analyzes, guidelines for the further operation were given.
PL
Niejednokrotnie drewno uznawane jest za jeden z najmniej trwałych materiałów budowlanych, nie wykazuje na zewnątrz symptomów degradacji biologicznej, niezależnie od wieku, który nie jest tu wykładnią jego zużycia technicznego. Wbrew pozorom, problem okazuje się bardzo szeroki i istotny, a jego wagę podkreśla nieświadomość społeczna istnienia takich zagrożeń w obiektach wyglądających na masywne i bezpieczne. W naszym otoczeniu znajduje się wiele takich konstrukcji, które są eksploatowane w warunkach nieświadomości o występujących zagrożeniach, jakie stwarza niewidoczne i zużyte technicznie drewno. Zły stan techniczny drewna niejednokrotnie bywa przyczyną katastrof budowlanych, szczególnie gdy dotyczy to belek stropowych, które utraciły swoje oparcie na murach wskutek korozji końcówek. W tych miejscach elementy te nie są praktycznie badane, a są to lokalizacje największych dla nich zagrożeń, natomiast zakres uszkodzeń drewna ujawnia się zazwyczaj w momencie katastrofy budowlanej lub wymiany stropu. Dlatego, problem ten należy uznać za badawczy, wymagający pilnego i kompleksowego rozwiązania nie tylko ze względu na ratowanie wartości historycznej (zabytkowej) niektórych budynków i budowli, ale przede wszystkim ze względu na ich bezpieczeństwo użytkowe. Zarówno w na etapie projektowania, wykonawstwa, jak i eksploatacji zapomina się o procesach fizykalnych zachodzących we wnętrzu przegród, od których w bardzo wysokim stopniu zależy rodzaj, intensywność i zasięg korozji biologicznej. W artykule zaprezentowany zostanie przykład wpływu korozji biologicznej drewna na bezpieczeństwo użytkowania magazynu pasz objętościowych. Wykonane „in situ” pomiary ubytków w przekrojach belek drewnianych, spowodowanych korozją biologiczną, zweryfikowane zostaną obliczeniami sprawdzającymi pod kątem ich nośności w stosunku do zakładanych dla nich wielkości obciążeń. Obliczenia zostaną przeprowadzone tu zarówno dla belek uszkodzonych, o zmniejszonych przekrojach poprzecznych, jak i dla elementów pełnowartościowych.
EN
In spite of appearances, the problem is very complex and significant, and its gravity is stressed by the lack of social awareness about the existence of such hazards in buildings which look massive and safe. There are a number of such facilities in our surroundings which are unconsciously used without proper knowledge of hazards posed by invisible and technically worn wood. The condition of wood is a cause of many construction disasters which may progress in the foreseeable future due to damaged ceilings in which beams had lost their support on walls through biological corrosion of the beam ends. There are a few reasons for such effects. Although these are points where the most serious hazards occur, such elements are practically not checked within the said areas. In contrast, the scope of wood damage becomes apparent usually at the moment of a construction disaster or demolition. Therefore, this problem should be deemed a research one which requires an urgent and effective solution not only in order to preserve the historical (heritage) value of such buildings and facilities but also to protect human health and life. This would entail determination of the most common reasons of degradation of wood and its durability over time. Physical processes occurring inside barriers, on whose the type, intensity and range of biological corrosion depend to a great extent, are ignored. This article presents an example of the influence of wood biological corrosion on operational safety of a roughage storehouse. In situ measurements of defects caused by wood biological corrosion were carried out and followed by static and strength calculations considering biological corrosion or without taking it into account.
PL
W artykule przedstawiono wyniki analiz doświadczalnych propagacji fal sprężystych w modelu laboratoryjnym połączenia nakładkowego dwuteowego dźwigara blachownicowego. Badano możliwość wykrycia całkowitego poluzowania pojedynczych śrub i grup łączników. Przeanalizowano zmiany jakościowe zarejestrowanych sygnałów, ich wpływ na energię sygnału oraz współczynnik korelacji krzyżowej. Wykazano możliwość zastosowania fal sprężystych do wykrywania uszkodzenia i jego ewolucji.
EN
This article presents results of experimental analyses of elastic wave propagation in a laboratory model of the double-T plate girder splice connection. The possibility of detection of complete loosening of individual fasteners and their groups was examined. The qualitative changes of recorded signals, their influence on the signal energy and the cross-correlation coefficient were analysed. It has been shown, that the elastic waves can be effectively used for damage detection and its evolution.
EN
The article presents a geotechnical hazard neutralisation technology for shaft structures. The diagnosis of problems with uncontrolled subsidence of the ventilation duct provided by the authors enabled the development of a schedule of works required for the protection and reinforcement of foundation soil in the shaft area. The technology of protection works was selected after the analysis of the technical condition of shaft structures as well as hydrological and geomechanical conditions. Due to the closeness of the shaft lining, it was necessary to form grout columns using jet grouting and low-pressure grouting technologies. The article presents the issues related to the selected technology and its application to the neutralisation of the emergent geotechnical hazard. The method of performance of recommended works was also described together with their impact on the technical condition of structures discussed as well as their functionality and usage.
6
Content available remote Drewno klejone warstwowo. Diagnostyka i ocena konstrukcji hali sportowej
EN
The paper presents the results of analysis of poorly designed and build the glued laminated timber frame structure of sport hall. The analysis is connected with capacity and stiffness of the elements and fasteners, as well.
PL
W pracy przedstawiono metodę badawczą opartą na pomiarze emisji akustycznej towarzyszącej powstawaniu i rozwojowi uszkodzeń, takich jak: zarysowanie betonu, pękanie na granicy zbrojenie-beton, uplastycznienie zbrojenia, przemieszczanie zbrojenia względem betonu, tarcie wzajemne między powierzchniami pęknięcia w betonie lub na granicy betonu i zbrojenia, występujących w obiektach strunobetonowych. Zastosowanie metody nie osłabia konstrukcji oraz pozwala na objęcie obszarem pomiarowym całego obiektu podczas jego eksploatacji.
first rewind previous Strona / 1 next fast forward last