Most of the small water companies supplying a small number of consumers with water are struggling with the extremely tight budget, often making any large-scale modernisation impossible. In effect network managed by these companies is often very leaky and unreliable. One possible and cheap way of leakage reduction is the reduction of average pressure in the network. Thanks to new computing technologies, the device selection process for pressure reduction is accurate and easy to do. This study uses the hydraulic model to select required pressure reducing valves and correct locations accurately and adequately approximate the resulting absolute water loss reduction thanks to this approach.
PL
Większość małych przedsiębiorstw wodociągowych boryka się z problemami budżetowymi. Mogą mieć one wiele źródeł – obłsuga niewielkiej ilości odbiorców, wysoki poziom strat, konieczność zakupu wody z zewnętrznych źródeł. Czynniki te sprawiają, że wymagane nakłady na modernizacje sieci niejednokrotnie przewyższają możliwości finansowe przedsiębiorstwa. Jednym ze sposobów redukcji rzeczywistych strat wody jest obniżenie średniego ciśnienia w sieci. Dzięki nowym metodom obliczeniowym i symulacjom komputerowym dobór urządzeń redukujących ciśnienie i wybór lokalizacji ich montażu są znacznie ułatwione. W pracy skupiono się na ocenie możliwości wykorzystania modelowania komputerowego podczas wdrażania systemu zarządzania ciśnieniem w sieci wodociągowej.
EN
This article presents the results of analysis of an urban-rural water supply system. The level of water losses and failure frequency of the water supply system were evaluated. Tests and analyses of the level of water losses were conducted for the years 2010-2016. Tests and analyses of failure frequency were conducted for the years 2013-2016. The guidelines of the International Water Association were applied in calculations. Analyses showed an influence of season on the failure frequency of the urban-rural water supply system. An influence of the number of failures on the volume of water lost in a single failure was also observed. Obtained results were compared with data from domestic literature and the guidelines of standard PN-EN 60300-3-4:2008.
7
Content available Accuracy of water meters during their operation
EN
The article describes the study on water meters after their five-year period of operation. Water meters were tested at a certification stand to check for possible reading errors. The following devices have been included in the study: water meters with a diameter of 20 mm (single-jet, multi-jet and volumetric) as well as single-jet and screw water meters with a diameter of 50 mm. The faulty water meters were disassembled to identify causes of damage specific for various types of water meters. The percentage of faulty water meters differed among individual types of water meters, as well as among single-jet water meters of different manufacturers. The tests carried out should verify the actual errors of water meter readings during and after operation, and check whether the errors vary for different types of water meters. After many years of operational experience, it may be concluded that water meters, if lose their correct metrological properties, they usually show a smaller values than the actual flow. In such cases, faulty water meters cause the apparent water loss. Based on the study the authors found that volumetric water meters had the highest reliability among household water meters while screw water meters among industrial water meters. The studies have confirmed that damaged water meters can contribute to higher apparent water losses.
8
EN
The water losses are unavoidable and the amount of loss may vary depending on the type of mains material, structure and operational parameters. The evaluation of water loss is an individual issue and should be done in terms of length of mains. In accordance with IWA terms (International Water Associations) there’s more often used economic level of leakages then percentage of water loss. The paper refers to the efforts to reduce the losses in one of the largest water companies in Poland – in Krakow. Those efforts should be conducted according to established strategy and aim to optimize the costs of operation in Water Company.
20
Content available remote Analiza strat wody w sieci wodociągowej w Stalowej Woli
PL
W publikacji przedstawiono analizę strat wody w sieci wodociągowej Stalowej Woli przeprowadzoną na podstawie danych uzyskanych z Miejskiego Zakładu Komunalnego Sp. z o. o. Stalowa Wola podczas eksploatacji sieci wodociągowej w latach 2008-2013, a także danych Głównego Urzędu Statystycznego. Oszacowane straty wody mają wartości niższe niż te odnotowane przez inne systemy zaopatrzenia w wodę. W pracy dokonano także charakterystyki podstawowych informacji o systemie zaopatrzenia w wodę w Stalowej Woli. Uzyskane wyniki odniesiono do danych innych systemów zaopatrzenia w wodę znajdujących się w województwie podkarpackim. Obliczenie jednostkowych wskaźników strat wody pozwoliło na uzyskanie szczegółowego obrazu sytuacji eksploatacyjnej wodociągu. Wszystkie jednostkowe wskaźniki objętościowe dotyczące strat wody wykazują tendencję malejącą w badanym okresie. Jednostkowy wskaźnik obciążenia hydraulicznego w odniesieniu do całej długości sieci wodociągowej w przeciągu ostatnich 5 lat wahał się w granicach od 37,73 do 42,33 m3/km⋅d. Wskaźnik średniej wielkości strat w ciągu doby na jednego mieszkańca jest zbliżony do wartości odnotowanych w innych miastach w Polsce i zawiera się w przedziale od 5,99 do 11,96 dm3/M⋅d. Korzystny jest także iloraz rzeczywistych strat rocznych oraz nieuniknionych strat rzeczywistych definiowany jako infrastrukturalny indeks wycieków, który wynosi od 1,6 do 3,3.
EN
In the article the analysis of water losses of the Stalowa Wola water network has been presented made on the basis of data obtained from the Municipal Department Sp. z oo Stalowa Wola during the networkoperation of water supply system in the period 2008-2013, as well as the data from the Central Statistical Office. Estimated water losses indicators have better values than the other water supply systems.The work also includes basic information about the characteristics of the water supply system in Stalowa Wola. The results regarded other water supply systems located in Podkarpackie province. An analysis of the distributional (up to 6.2 km) and water supply connections lengths (an increase of 58.9 km) indicates that the water network of Stalowa Wola is constantly expanded. The calculation of unit rates of water loss allowed to obtain a detailed picture of the operational situation of the operational water supply. All unit volume indicators on water losses show a downward trend in the considered period. Unit hydraulic loading rate for the entire length of the water supply network-provided for the past 5 years ranges from 37.73 to 42.33 m3/km⋅d.Index of the average size of losses per day per capita is similar to other cities in Poland ranges from 5.99 to 11.96 dm3/M⋅d. The quotient of the actual losses and unavoidable annual real losses defined as infrastructure leakage index is preferred and ranges from 1.6 to 3.3.