Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  stosunek powierzchni
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The present experimental evaluation deals with the behavior of base pressure (BP) in a suddenly expanded duct at supersonic Mach number regimes. The experiments have been conducted for two cases viz. Without and with the use of microjets or active control. The plan of experiments was planned as per Taguchi design of experiments for acquiring data in a controlled manner. An L27 orthogonal array and analysis of variance (ANOVA) has been employed to investigate the contribution (in terms of percentage) of distinct process parameters like Mach number (M), Nozzle Pressure Ratio (N), Area Ratio (A) and their interactions affecting base pressure. The correlation between these parameters affecting base pressure has been obtained using multiple linear regression analysis. It has been concluded that the Mach number and area ratio were the factors that had high statistical significance on the behavior of base pressure for both cases. The performances of the developed linear regression models have been validated for accuracy prediction by use of 15 test cases. The performance of both the base pressure models was found to be better with percentage prediction in deviation lying in the range of –12.92% to +15.88% for base pressure without control and –10.27% to +19.23% for base pressure with control.
EN
Performance assessment of ejector-expansion vapor compression refrigeration system with eco-friendly R134a alternative refrigerants (R152a, R1234yf, R600a, R600, R290, R161, R32, and propylene) is presented for air-conditioning application. Ejector has been modeled by considering experimental data based correlations of component efficiencies to take care of all irreversibilities. Ejector area ratio has been optimized based on maximum coefficient of performance (COP) for typical air-conditioner operating temperatures. Selected refrigerants have been compared based on area ratio, pressure lift ratio, entrainment ratio, COP, COP improvement and volumetric cooling capacity. Effects of normal boiling point and critical point on the performances have been studied as well. Using ejector as an expansion device, maximum improvement in COP is noted in R1234yf (10.1%), which reduces the COP deviation with R134a (4.5% less in basic cycle and 2.5% less in ejector cycle). Hence, R1234yf seems to be best alternative for ejector expansion system due to its mild flammability and comparable volumetric capacity and cooling COP. refrigerant R161 is superior to R134a in terms of both COP and volumetric cooling capacity, although may be restricted for low capacity application due to its flammability.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.