Poly(L-lactide-co-glycolide-co-trimethylene carbonate) rods with risperidone and 17-β-estradiol were sterilized by electron beam irradiation. The aim of the study was to assess electron beam irradiation impact on terpolymer composition, chain microstructure, glass transition temperature, molecular weight and the morphological features of rods. Methods: Hot melt extrusion in the formulation of rods was applied. Sterilization of the rods was performed by electron beam in an electron beam accelerator (10 MeV, 360 mA, 25 kGy). The following methods in the development of rods were applied: nuclear magnetic resonance, differential scanning calorimetry, gel permeation chromatography and scanning electron microscopy. Results: Sterilization influenced only glass transition temperature in blind rods and rods with risperidone. As for the other parameters, no significant changes were observed as far as a sterilization effect is concerned. However, some changes were noted after introducing drug substances and after extrusion. Conclusions: Electron beam irradiation of rods with risperidone and rods with 17-β-estradiol is an adequate method for sterilizing implantable drug delivery systems.
EN
Effect of electron beam irradiation with a dose equivalent to that used in practice during radiation sterilization of endoprostheses (26 kGy) or twice higher (2 ź 26 kGy) on the change of UHMW-PE structure. UHMW-PE (trade name Chirulen 1120) is used for preparation of cups of hip endoprostheses. Structural changes of the polymer have been investigated using FT-IR method. Mainly the results of polymer oxidation (increase in the part of carbonyl groups of ketone, ester and perester types as well as of hydroxyl and vinyl groups) have been found. It was also found, using GPC method, that irradiation caused also partial degradation of macromolecules (reduction of molecular weight one order of magnitude) and crosslinking processes were favored by macroradicals formed (gel fraction part about 40 %, increase in melting temperature as well as in crystallinity degree).
PL
Określono wpływ napromieniania strumieniem elektronów dawką równoważną stosowanej w praktyce podczas sterylizaqi radiacyjnej endoprotez chirurgicznych (26 kGy) oraz dwukrotnie większą (2 ź 26 kGy) na zmianę struktury PE-UHMW o nazwie handlowej "Chirulen 1120" (tabela 1) służącego do otrzymywania panewek endoprotez biodrowych. Metodą FT-IR zbadano zmiany strukturalne polimeru, stwierdzając głównie występowanie skutków jego utlenienia (wzrost udziału grup karbonylowych typu ketonowego, estrowego i nadestrowego, grup hydroksylowych oraz winylowych) (rys. 1). Metodą GPC stwierdzono, że napromienianie powoduje także częściową degradację makrocząsteczek (zmniejszenie ciężaru cząsteczkowego o jeden rząd wielkości), a wytworzone makrorodniki sprzyjają procesom sieciowania (wynoszący ok. 40 % udział frakcji żelowej, wzrost temperatury topnienia i stopnia krystaliczności) (tabela 2).
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.