This article discusses the impacts of overprinting of tectonic and plutonic events on the mineralization of the Duna Pb-Ba ore deposit, according to geologic settings and fluid inclusion studies. The Duna carbonate-hosted deposit contains a significant amount of Ag (18.9–264.3 ppm ), Cu (77–41600 ppm), Sb (32.7–11000 ppm), Sr (63.5–15100 ppm), and Fluid inclusions with 7.34–23.65 wt.% NaCl equivalent. The homogenization temperature of about 110–285°C, as well as the paragenesis of the minerals shows a difference compared with other Pb-Zn deposits such as the Irish-type and MVT. The ore mineralization in the Duna mine occurred as stratabound, open space-filling, and along the brecciated fault zones. The concordant (stratabound) type of mineralization, with salinity and homogenization temperature of 18.54 to 23.65 wt.% NaCl equivalent, and 113°C to 165°C respectively, is usually typical of MVT-ore deposits, which in this area evolved during the Early Cimmerian orogeny and was later interrupted by mineralization along younger brecciated fault zones with salinity and homogenization temperature of 7.34 to 23.65 wt.% NaCl equivalent, and 113°C to 285°C respectively. This discordant mineralization, which occurred along the faults, formed by the end of the Late Cretaceous and during the Cenozoic as a result of the intrusion of a plutonic mass, and is comparable to the Irish-type ore deposits.
2
Content available remote On the semi-active control of carrying structures under a moving load
EN
In this paper we address a group of recent research focused on the semi active control problems in carrying structures systems subjected to a travelling load. The magnitude of the moving force is assumed to be constant by neglecting inertial forces. The response of the system is solved in modal space. The optimal control problem is stated and it is solved by using of Pontryagin Maximum Principle. Switching control method is verified by numerical examples. The controlled system widely outperforms passive solutions. Due to its simplicity in practical design, the presented solution should be interesting to engineers.
PL
W pracy przedstawiono wyniki badań półaktywnego sterowania w układach nośnych poddanym obciążeniom ruchomym. Obciążenie zostało przedstawione jako bezinercyjne. Odpowiedź układu została wyznaczona w reprezentacji modalnej. Sformułowano zadanie sterowania optymalnego. Uzasadniono zastosowanie sterowań typu bang-bang opierając się na Twierdzeniu o Maksimum Pontryagina. Proponowana metoda sterowania została zweryfikowana na podstawie przykładów numerycznych. Wykazano przewagę układów sterowanych nad układami tłumienia pasywnego. Opracowana strategia sterowania jest prosta w implementacji i może być atrakcyjnym rozwiązaniem dla inżynierów.