Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  sterowanie prądem
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
At carrying out the experiments to determine the losses for heating of magnetic nanoparticles (MNP) and composites on their basis, which are commonly used in the cancer treatment, it is necessary to reduce the number of manually regulated processes, e.g.: frequency change and resonance adjustment, alternating magnetic field strength amplitude change, as well as the measurements. In present article structural diagram of device for such purposes with improved automation level is presented and circuit engineering solutions for main measurement and automation nodes are proposed. There is an attempt to perform a purely electronic control of current flowing through the heating solenoid coil to adjust the magnetic field strength applied to the MNP sample without using any additional power electronics components.
EN
This paper presents a novel design and analysis of an odd-harmonic repetitive control (ORC) for a two-level three-phase grid connected voltage source inverter. An LCL filter between the inverter and the grid is used to attenuate high frequency PWM switching harmonics. The controller lowers the memory requirement, compared to a conventional repetitive controller. The control scheme contains a traditional conventional tracking controller with a dual loop feedback system, and a zero-phase noncasual filter with add-on ORC. Our analysis and simulation results suggest that the proposed control scheme is able to provide high quality output current (THD=1.8 %) even in worst case scenario.
PL
W artykule przedstawiono nową strategię sterowania ORC (ang. Odd-harmonic Repetitive Control) dla trójfazowego, dwupoziomowego sieciowego przekształtnika napięcia. Dodatkowo wykorzystano filtr wyjściowy LCL. Algorytm redukuje ilość wymaganej pamięci. Jego struktura opiera się na sterowniku nadążnym z podwójną pętlą sprzężenia zwrotnego, filtrze o zerowym przesunięciu fazy oraz ORC. Analiza i symulacje wykazały, że proponowane sterowanie może zapewnić wysokiej jakości prąd (THD=1,8%).
3
Content available remote Sterowanie spawarek MIG/MAG
PL
Artykuły dotyczące teorii budowy urządzeń spawaIniczych wyposażonych w zaawansowane systemy sterawania nierzadko publikowane są w Przeglądzie Spawalnictwa. Niniejszy artykuł przedstawia stosowane w nowoczesnych urządzeniach sposoby sterowania napięciem i prądem łuku spawalniczego wraz ze zwięzłą charakterystyką podstawowych różnic w sterowaniu.
EN
Articles regarding the theory of design of welding machines with high-tech control systems are often published in Welding Technology Review. Used in modern welding machines voltage and current control systems with brief characteristic of fundamental differences in regulation are presented in this article.
EN
The description of the properties of converter fed induction machines as a function of rotor frequency instead of slip is utmost preferable, if the motor is used in speed variable drive systems. By this scheme all data can be described independently from the actual rotor speed or feeding frequency of the converter. Based on numerical field calculations current control schemes were evaluated for optimal use of converter capability for static and transient loads. The optimization goals are minimization of both stator and rotor losses and the response time on transient load changes.
PL
Opis własności maszyn indukcyjnych zasilanych z przekształtników w funkcji częstotliwości prądów wirnika, zamiast w funkcji poślizgu, jest korzystniejszy przy analizie napędów wysokoobrotowych. W przypadku tym wszystkie dane mogą być opisane niezależnie od aktualnej prędkości wirnika czy częstotliwości przekształtnika. Bazując na obliczeniach polowych opracowano schematy sterownia, celem optymalnego wykorzystania możliwości przekształtnika w przypadku obciążeń stałych i przejściowych. Celem optymalizacji jest minimalizacja strat stojana i wirnika oraz odpowiedzi czasowej w przypadku przejściowych zmian obciążenia.
EN
In the majority of electric trolley locomotives operated in Polish mines, a significant (3:1) main poles' field weakening in the traction machines is necessary. In the paper, special attention was paid to an analysis and results of laboratory tests of a transistor-based system designed for a pulse-mode control of the traction motors' excitation current of the locomotive type Ld31 (90 kW). A capacitor connected in parallel to the excitation winding of the traction motor is discharged through an resistor in the described system. Consequences of the significant differences in the current overload capacity of power transistors and SCR thyristors were presented. The relationships between a field weakening rate and an armature current for different switch duty ratios of the transistor were obtained on the basis of an approximate analysis of the system operation. The steady-state characteristic curves of the excitation current versus the armature current and power losses in the resistor were found using Maple computer algebra system. Results of the laboratory tests concerning the relationship between the excitation current and the armature current and selected oscillograms of the voltage and current waveforms were also shown.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.