Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  sterowanie mocą bierną
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The FACTS (Flexible AC Transmission System) devices have been considered as excellent controllers in a power system for better reliability and transmission capacity on a long-term and cost-effective basis. The static synchronous series compensator (SSSC) is one of robust FACTS devices that can control the flow of power in AC lines. In this paper, modelling and simulation of active and reactive power flow control in transmission lines and voltage control using SSSC with adaptive neuro-fuzzy logic is proposed. The mathematical model of SSSC in power flow is also proposed. The results show the ability of SSSC to control the flow of power in the AC lines of power system within line voltage limitations.
PL
Przedstawiono modelowanie i symulację sterowania przepływem mocy czynnej I biernej przy wykorzystaniu SSSC (synchroniczne kompensatory szeregowe) oraz zastosowaniu adaptacyjnej logiki neuro-fuzzy. Przedstawiono model matematyczny systemu SSSC.
2
EN
In this paper the results of the development of voltage and reactive power regulation algorithm based on the particle swarm method, optimizing the electric power system mode by the level of losses, are presented. To provide an integration of this algorithm into a real system of an automated dispatching control system, the algorithm is implemented using programs, which are used in the System Operator of the Unified Power System of Russia, as well as standard communication protocols and a software platform. The analysis and comparison of the optimization results obtained by the particle swarm method and standard optimization method (gradient descent method), realized in RastrWin, confirm the correctness and reliability of the obtained results and the developed algorithm. At the same time, the algorithm does not depend on the initial conditions (setpoints), set on the control objects, which allows it to be used to optimize the modes of complex power network, finding the balance in which is a time-consuming task. In the future, it is planned to develop an algorithm for optimizing the mode, taking into account the increased stability of the electric power system.
PL
W artykule przedstawiono metodę sterowania napięciem I moca bierną bazującą na algorytmach rojowych. Algorytm zaadaptowano do rzeczywistych warunków sieci dystrybucyjnej w Rosji. Sprawdzono praće algorytmu badając stabilność I niezawodność systemu. W dalszym etapie planuje się zastosowanie metody do optymalizacji sieci zasilania.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.