Introduction: The aim of this study was to evaluate the new 2-Dimensional diode array SRS MapCHECK (SunNuclear, Melbourne, USA) with dedicated phantom StereoPHAN (SunNuclear, Melbourne, USA) for the pre-treatment verification of the stereotactic body radiotherapy (SBRT). Material and methods: For the system, the short and mid-long stability, dose linearity with MU, angular dependence, and field size dependence (ratio of relative output factor) were measured. The results of verification for 15 pre-treatment cancer patients (5 brains, 5 lungs, and 5 livers) performed with SRS MapCHECK and EBT3 Gafchromic films were compared. All the SBRT plans were optimized with the Eclipse (v. 15.6, Varian, Palo Alto, USA) treatment planning system (TPS) using the Acuros XB (Varian, Palo Alto, USA) dose calculation algorithm and were delivered to the Varian EDGE® (Varian, Palo Alto, USA) accelerator equipped with a high-definition multileaf collimator. The 6MV flattening-filter-free beam (FFF) was used. Results: Short and mid-long stability of SRS MapCHECK was very good (0.1%-0.2%), dose linearity with MU and dependence of the response of the detector on field size results were also acceptable (for dose linearity R2 = 1 and 6% difference between microDiamond and SRS MapCHECK response for the smallest field of 1 × 1 cm2). The angular dependence was very good except for the angles close to 90° and 270°. For pre-treatment plan verification, the gamma method was used with the criteria of 3% dose difference and 3 mm distance to agreement (3%/3 mm), and 2%/2 mm, 1%/1 mm, 3%/1 mm, and 2%/1 mm. The highest passing rate for all criteria was observed on the SRS MapCHECK system. Conclusions: It is concluded that SRS MapCHECK with StereoPHAN has sufficient potential for pre-treatment verification of the SBRT plans, so that verification of stereotactic plans can be significantly accelerated.
PL
Stereotaksja jest nowoczesną, wysokospecjalistyczną metodą leczenia nowotworów, która może być stosowana m.in. w przypadku zmian przerzutowych lub pierwotnych w obszarze głowy. Technika ta wymaga bardzo dużej precyzji oraz dokładności na każdym etapie leczenia. Jednym z etapów przygotowywania stereotaktycznego planu leczenia jest faza weryfikacji dozymetrycznej, która ma miejsce przed kliniczną implementacją planu. Celem pracy było sprawdzenie, czy rozmiar napromienianej stereotaktycznie zmiany może mieć wpływ na wynik weryfikacji wykonanej z użyciem detektora EPID i analizy gamma. Wykonano 28 planów stereotaktycznego leczenia w obszarze głowy. Dla każdego planu wyliczono mapę fluencji, którą zmierzono z wykorzystaniem detektora EPID. Zmierzone rozkłady fluencji porównano z mapami fluencji wygenerowanymi z systemu planowania leczenia. Do oceny zgodności wykorzystano analizę współczynnika gamma. Analizę statystyczną wyników oparto na analizie współczynnika rho Spearmana, przy ustalonym poziomie istotności α równym 0,5. Wnioski z przeprowadzonego badania wykazały, że dla zadanych kryteriów nie ma zależności pomiędzy wielkością napromienianej zmiany (targetu) a wynikiem analizy gamma. Potwierdza to użyteczność stosowania detektora EPID przy dozymetrycznych weryfikacjach radioterapeutycznych planów stereotaktycznych.
EN
Stereotactic radiotherapy is a modern, highly sophisticated treatment method which is often used for neoplastic lesions in head’s area. This technique requires a very high precision and accuracy at each treatment stage. One part of treatment preparation is phase of the pre-treatment dosimetric verification. The main objective of this research was to check whether the size of irradiated target affect the results of verification performed with the EPID detector, based on the use of gamma analysis. Dose fluency was measured for twenty eight stereotactic treatment plans with EPID detector. The measured fluency distributions were compared with generated ones by using gamma analysis. Spearman’s rank correlation test was performed (α = 0,05). The conclusions from the study showed that for the given criteria, there is no relationship between the size of the irradiated lesion (target) and the result of the gamma analysis. This confirms the usefulness of using the EPID detector in dosimetric verifications of stereotactic radiotherapy.
PL
Radioterapia stereotaktyczna i radiochirurgia wymagają dostarczenia wysokiej dawki promieniowania do bardzo małego obszaru napromieniania w jednej lub kilku frakcjach. Założenia takiego leczenia wymagają od fizyka planującego leczenia zwrócenia szczególnej uwagi na analizę gradientu spadku dawki wokół targetu. W niniejszej pracy przedstawiono propozycję ilościowej analizy gradientu spadku dawki opartej na zbudowanym modelu zależności promienia równoważnego od wielkości napromienianej zmiany. Model wykazał liniową zależność parametrów. Na jego podstawie możliwe staje się opracowanie wewnętrznych poziomów referencyjnych dotyczących gradientu spadku dawki w planie leczenia. Niniejsza praca jest równocześnie próbą oraz propozycją przedstawienia wewnętrznej analizy gradientu spadku dawki w planach leczeniach dotyczących stereotaksji oraz radiochirurgii okolicy głowy.
EN
Stereotactic radiotherapy (SRT) and radiosurgery (SRS) require a high dose of radiation to be delivered to a very small area in one or more fractions. Assumptions of such treatment oblique the medical physicist to pay special attention to analyse the dose distributiom inside and outside the target. In this article there is a proposal for quantitative analysis of the dose decrease gradient based on the built dependence model of the equivalent radius and the size of the irradiated volume. The model showed a linear relationship of considered parameters. On its basis it becomes possible to establish internal reference levels for the dose gradient in treatment plan. This work is the proposal to apply the dose gradient analysis for assessment of SRT and SRS treatment plans in the head area.