EN
In recent years, there is increasing interest to create biodegradable metallic cardiovascular stents instead of using their permanent form. The most interesting materials for this purpose are iron and its alloys. However, in order to use it in clinical application, their degradation rate and biological performance need to be optimized. One promising solution is coating the metal with conducting polymer films. In this work, short overview of the use of the biodegradable iron and iron modified with polypyrrole as materials for cardiovascular stents is presented.
PL
Zastosowanie biodegradowalnych, metalicznych stentów naczyniowych staje się alternatywą dla obecnie używanych ich stałych form. Długotrwała obecność metalowego stentu w tętnicy może prowadzić do powikłań, takich jak zakrzepica czy restenoza w stencie. Odrębnym problemem może być pęknięcie stentu. Dlatego też, prowadzone są badania nad ich biodegradowalnymi formami. W tym celu stosowane są aktywne metale takie, jak na przykład żelazo, których biodegradowalność oparta jest na procesie korozji. Jednak, użycie tych materiałów do zastosowań klinicznych wymaga optymalizacji ich szybkości degradacji. Obiecującym rozwiązaniem jest powlekanie powierzchni takich metali warstwami z polimerów przewodzących. W pracy przedstawiono krótki przegląd wykorzystania biodegradowalnego żelaza oraz żelaza modyfikowanego powłokami z polipirolu, jako materiałów dla stentów sercowo-naczyniowych.
7
Content available remote Oddziaływanie aplikatorów pola magnetycznego na stenty
PL
Położenie stentu może mieć znaczący wpływ na osiągane wartości prądów indukowanych w poszczególnych gałęziach. W artykule przedstawiono również rezultaty, w których założono możliwość wystąpienia przypadku najgorszego, z punktu widzenia ewentualnego zagrożenia. W artykule przedstawiono wyniki dla jednej, przykładowej budowy stentu. Dalsze badania, powinny brać także pod uwagę szereg innych sposobów budowy stentu, znacznie bardziej zagęszczoną siatkę tworzoną przez jego gałęzie.
EN
The position of the stent may have a significant impact on its currents induced in the branches. The results are presented for the case that poses the highest danger. The results were obtained for one exemplary construction of the stent. Further research should also take into account a number of other ways of building a stent, and a much more dense mesh created by its branches.
PL
W artykule przedstawiono analizę morfologii przełomów w stopie L605 poddanego różnym wariantom obróbki cieplnej wieloetapowej. Badano wpływ elementów struktury (węgliki) na charakter przełomów. Analizowano przełomy cienkościennych konstrukcji stentów uzyskane poprzez mechaniczne, wymuszone zniszczenie siłą przyłożoną w kierunku osi stentu. Analiza miała charakter porównawczy. Obrazy przełomów uzyskano dzięki zastosowaniu elektronowego mikroskopu skaningowego (SEM).
EN
The article presents the analysis of the morphology of the fractures in the alloy L605, subjected to different variants of multi-stage heat treatment. The impact of the structural elements (carbides) on the nature of the fractures has been examined. The fractures of thin wall constructions of stents have been analyzed. They have been obtained by mechanical, forced destruction by means of the force applied in the axial direction of the stent. It has been the comparative analysis. The images of the fractures have been obtained thanks to the application of a scanning electron microscope (SEM).
PL
Choroby układu naczyniowo-sercowego wysuwają się na czołowe miejsce w statystyce zgonów w naszym stuleciu. Obecnie w Polsce choroba nie-dokrwienna serca dotyczy prawie miliona mieszkańców, a rocznie z jej powodu umiera około 90 000 ludzi. Jedną z najczęściej stosowanych metod leczenia jest angioplastyka naczyń wieńcowych za pomocą stentów. Mimo istnienia na rynku wielu rodzajów stentów nadal występuje konieczność szukania nowych technolo-gii i materiałów zapewniających lepsze własności mechaniczne, fizykochemiczne i biomedyczne stentów.
EN
Diseases of the cardiovascular system have a high position in the sta-tistics of deaths in our century. Now in Poland, ischemic heart disease affects al-most a million people and per year die of about 90,000. One of the most com-monly used treatment methods is the coronary angioplasty with the stents. Exi-stence many types of stents, but still need to look for new technologies and mate-rials to ensure better mechanical properties, physico-chemical and biomedical stents.
PL
W niniejszej pracy skoncentrowano się na wytypowaniu i obserwacji miejsc uznanych za newralgiczne w stentach wykonanych z nitinolu, przed i po przeprowadzeniu prób niskocyklowego odkształcenia. Podjęto próby określenia charakteru uszkodzeń stentów będących bezpośrednio po przeprowadzonych zabiegach obróbki cieplnej, jak również stentów po przeprowadzonych zabiegach chemicznej obróbki powierzchniowej (polerowaniu) jako produkcie finalnym. Do celow badawczych wykorzystano zaprojektowane i wykonane w Instytucie Mechaniki Precyzyjnej w Warszawie stanowisko diagnostyczne, realizujące cykliczne odkształcenie sprężyste w płaszczyźnie równoległej do osi stentu. Opisana w pracy próba wczesnego wykrywania wad w stentach z nitionolu z zastosowaniem niskocyklowego odkształcenia pozwala zaobserwować symptomy świadczące o możliwości inicjacji i rozwoju pęknięć w konstrukcji stentów.
EN
In this work focuses on the designation and observation locations considered sensitive to stents made from nitinol, before and after low cycled deformation testing. Attempts were made to determine the nature of the damage to the stent being conducted immediately after the heat treatment procedures, as well as stents after the treatments of chemical surface treatment (polishing), as the final product. Used for research purposes designed and built at the Institute of Precision Mechanics in Warsaw diagnostic stand, performing cyclic elastic deformation in a plane parallel to the axis of the stent. In the work the test of early detection of defects in stents of nitionol was used. Using low cycled deformation it was allowed to observe symptoms indicated the possibility of the initiation and development of cracks in the structure of stents.
EN
Endovascular stents, such as coronary stents are widely used for the treatment of narrowed or blocked blood vessels. We developed a new experimental method to measure the metallic surface area (MSA) of stents. Our aim was to compare this method with the previously used. According to the results we could make a suggestion to use the new automatic method, because this gives the most and accurate information in the shortest time. The collected experience and results of this study can help physicians to choose an appropriate stent.
PL
Zaprojektowano i wykonano stanowisko do diagnostyki mechanicznej stentów kardiologicznych. Przeprowadzono na nim wstępne badania porównawcze metodą zmęczenia przy zastosowaniu małej liczby cykli (na poziomie 1000) odkształceń sprężystych. Do rejestracji czasu pojedynczego cyklu i siły obciążenia, przy zadanym stopniu odkształcenia, wykorzystano program komputerowy. Analiza profili obciążenia pozwoliła na śledzenie reakcji materiału stentu na wymuszone odkształcenie sprężyste imitujące krytyczne odkształcenia stentu w naczyniach krwionośnych człowieka. Wykazano różnice w zachowaniu materiału stentów w zależności od stanu powierzchni (topografia), będące konsekwencją zastosowanych zabiegów technologicznych, jak wycinanie laserowe oraz polerowanie chemiczne. Pozwoliło to na określenie, na którym z etapów produkcji stenty narażone są najbardziej na zainicjowanie mikropęknięć, które mogą się rozwijać w kolejnych etapach produkcji, jak również w trakcie i po zabiegu implantacji.
EN
In our work we designed and manufactured the test stand for the mechanical diagnosis of cardioviscular stents and realized comparative studies, by the fatigue method with small number elastic cycles (1000 cycles level). The computer program was used for the registration of results. Analysis of load profiles allowed to track the response of the stent material on the forced elastic deformation, imitating the critical stent strain in the human blood vessels. The differences in the behavior of the material of stents according to the state of the surface (topography) were demonstrated, as a consequence of the applied technological treatments such as , laser cutting and chemical polishing. This made it possible to determine at which stage of the production the stents are most likely to initiate micro-cracks which t may develop in successive stages of production, as well as during and after implantation.
PL
W podjętych pracach zaprojektowano i wykonano stanowisko do diagnostyki mechanicznej stentów kardiologicznych oraz przeprowadzono na tym stanowisku wstępne badania porównawcze metodą zmęczenia przy małej liczbie cykli odkształceń sprężystych. Stanowisko diagnostyczne zostało zaprojektowane i wykonane w Instytucie Mechaniki Precyzyjnej w Warszawie. Budowę stanowiska diagnostycznego oparto na założeniu, że stent naczyniowy jest obciążony na całej długości obciążeniem prostopadłym do osi. Badanie miało również charakter treningu stosowanego do elementów z materiałów z pamięcią kształtu z możliwością regulacji stopnia odkształcenia sprężystego i częstotliwości obciążenia. Podczas badania ażurowy stent wykonuje niewielkie dyskretne ruchy wzdłuż swojej osi. Do rejestracji czasu pojedynczego cyklu i siły obciążenia przy zadanym stopniu odkształcenia wykorzystano dedykowany program komputerowy działający w środowisku Windows. Rejestrowane dane pozwalają na stworzenie profili obciążenia dla każdego z badanych stentów. Badania skoncentrowano na stentach wykonanych z nitinolu z pamięcią kształtu, pochodzących z różnych etapów cyklu produkcyjnego, mających różny stopień dokładności wykończenia powierzchni. Rejestrowane zmiany obciążenia dla poszczególnych cykli tworzą graficzny profil obciążenia w ramach pełnej próby do założonej liczby cykli. Analiza profili obciążenia pozwala na śledzenie reakcji materiału stentu na wymuszone odkształcenie sprężyste, imitujące krytyczne odkształcenia stentu w naczyniach krwionośnych człowieka. Wykazano różnice w zachowaniu materiału stentów w zależności od stanu powierzchni, będącej konsekwencją zastosowanych zabiegów technologicznych, takich jak wycinanie laserowe oraz czyszczenie chemiczne. Pozwoliło to na określenie, na którym z etapów produkcji stenty są najbardziej narażone na zainicjowanie mikropęknięć, które mogą rozwijać się w kolejnych etapach produkcji, jak również w trakcie i po zabiegu implantacji.
EN
In the work the diagnostic stand for mechanical diagnosis of cardiac stents has been designed and manufactured. Preliminary, comparative studies of fatigue at low number of cycles of elastic deformation have been performed. The diagnostic stand has been designed and made at the Institute of Precision Mechanics in Warsaw. The construction of the diagnostic stand based on the assumption that the vascular stent is loaded with the entire length of the load perpendicular to the axis. The study was the nature of training applied to the elements made of the shape-memory materials with the possibility of adjusting the degree of elastic deformation and load frequency. During the test, openwork stent partly performs small movements along its axis. Time registration and a single cycle of the load force at a given degree of deformation used a dedicated computer program running in Windows environment. The recorded data allows the creation of load profiles for each of the stents. The study focused on stents made of Nitinol shape memory alloy originating from different stages of the production cycle, with different degrees of accuracy of surface finishing. The recorded changes in load for individual cycles form graphic load profile in the context of the full sample to a predetermined number of cycles. Analysis of load profiles allows to track the stent material response on forced elastic deformation, imitating the critical strain of the stent in human blood vessels. Differences in the behaviour of the material, depending on the stent surface state as a consequence of treatments applied technology, such as cutting Laser and cleaning, have been shown. This made it possible to determine in which stages of the production stents are most likely to initiate microcracks that may develop in successive stages of production, as well as during and after implantation.
PL
Przedstawiono wybrane przykłady stentowania w obrębie przewodu pokarmowego ze szczególnym uwzględnieniem stentowania przełyku z wykorzystaniem wideoendoskopii. Omówiono rodzaje i właściwości stentów. Podano przykłady leczniczych aplikacji stentów w przewodzie pokarmowym. Podkreślono znaczenie jednoczesnego zastosowania różnych metod obrazowania.
EN
Some selected examples of stenting concerning the upper digestive tract with special attention to the esophagus stenting using videoendoscopy are presented. Types and properties of stents have been described. Examples of therapeutic applications of the stents are given. The importance of the use of combined imaging is emphasized.
PL
W pracy przedstawiono wyniki testów jednoosiowego rozciągania z próbą wyjaśnienia przyczyn niestabilności mechanicznej, niezwykle nierównomiernego rozprzestrzeniania się odkształcenia plastycznego w próbkach stopu kobaltu o składzie chemicznym zbliżonym do stopu typu L605, wyżarzanego w warunkach zastosowanych w eksperymencie (T = 1000°C, t = 45 min). Na wykresach rozciągania powyżej odcinka liniowego krzywej b-e występują silne, gwałtowne i skokowe zmiany odkształcenia o cechach odbiegających od zjawiska fizycznej granicy plastyczności w stalach węglowych i cech efektu Portevina-Le Chateliera występujących w stopach aluminium. Jest on podobny, lecz o znacznie większej intensywności niż stwierdzony niedawno w stalach austenitycznych. Autorzy proponują by ujawniony w tym konkretnym przypadku badanego stopu kobaltu efekt nazwać "super efektem Portevina-Le Chateliera". Zjawisko to może mieć bardzo duże znaczenie przy wytwarzaniu i eksploatacji wyrobów z tego typu stopów, na przykład stentów kardiologicznych.
EN
The article presents results of tension uniaxal tests with attempt explain the causes of mechanical instability, non-uniform propagation of plastic deformation in samples of cobalt alloy with chemical composition close to alloy L605, annealing in conditions used in experiments (T = 1000°C, t = 45 min). At the graph of stretching, above curve b-e are strong, violent and jumping changes of deformation with characteristics different from the physical of plasticity border in carbon steel and characteristics of effect Portevin-Le Chatelier appearance in alluminium alloys. It is similar but he has bigger intensity than found recently in austenitic steels. The authors propose to name it "super Portevien-Le Chatelier effect". This phenomenon can be very important in the manufacture and use of products from such alloys, for example cardioviscular stents.
PL
W pracy przedstawiono wyniki prób formowania prostych modeli spiralnych stentów z pamięcią kształtu przeznaczonych do leczenia górnych dróg oddechowych. Przeprowadzono krótką charakterystykę otrzymanych wyrobów w tym parametrów efektu pamięci kształtu. Niezależnie od rodzaju zastosowanego w formowaniu terpolimeru laktydu, glikolidu i węglanu trimetylenu wszystkie otrzymane stenty prezentowały efekt pamięci kształtu. Powrót do kształtu permanentnego, indukowany w temperaturze około 390C, trwał poniżej 3 minut, przy stopniu powrotu powyżej 99%. Najlepszą wytrzymałość mechaniczną wykazywały stenty otrzymane z terpolimeru o blokowej mikrostrukturze łańcucha. Przedstawiono również część wyników badań FTIR, próbujących wyjaśnić przyczynę zaistniałego zjawiska zapamiętywania kształtu w syntezowanych materiałach. Jak wynika z przeprowadzonych badań, główną przyczyną tego zjawiska wydają się być wiązania wodorowe i tworzenie kompleksów międzycząsteczkowych ugrupowań laktydylowych.
EN
The paper presents the results obtained during extrusion of simple spiral models of stents demonstrating shape memory behavior intended to use for treatment of upper respiratory tract. Brief description of obtained products and parameters of their shape memory effect are shown. Final products presented shape memory effect regardless of the type of used lactide/glycolide/ trimethylene carbonate terpolymer. In all cases, the return to preset shape took place at a temperature of about 390C and required less than three minutes to occur, with a great restoring degree of above 99%. The stents obtained with terpolymer containing block chain microstructure showed the best mechanical strength, enough for planned application. Some results of FTIR analysis were presented too, in an attempt to explain the cause of the shape memory phenomenon which is characteristic for synthesized terpolymers. The main causes of this phenomenon seem to be the creation of hydrogen bonds and intermolecular lactidyl complexes.
PL
Powikłania związane z chorobą miażdżycową są istotnym problemem kardiologii i kardiochirurgii. W walce z reste-nozą obiecujące są wyniki stosowania stentów uwalniających leki (DES - Drug Eluting Stents) lub stentów biode-gradowalnych. Niedawno opublikowane wyniki badań dotyczą też balonów powlekanymi lekami. W przypadku pojawienia się restenozy proponuje się wprowadzenie balonika, w celu zapewnienia kontaktu między tkanką a lekiem, którym powleczony jest balon (DEB - Drug Eluting Balloons). Z drugiej strony, coraz więcej funduszy, m.in. unijnych, przeznaczanych jest na rozwijanie technologii wytwarzania nowych biomateriałów. W jednym z takich projektów uczestniczą uczelnie wyższe z Wrocławia oraz firma produkująca stenty - Balton.
EN
Complications connected with atherosclerosis are still major problems in cardiology and cardiosurgery. One of the promising options in combating restenosis are Drug Eluting Stents (DES) and stents madę of biodegradable mate-rials. Recently published results deal with drug-coated balloons (DEB - Drug Eluting Balloons). It is proposed to insert catheter with drug eluting balloon in case of restenosis. So thus, the contact between the tissue and medica-ment entrapped in the balloon coating, is ensured. On the other hand, one of the newest trend is in materiał science, where the projects devoted to the new biomaterials are supported, among others by European Commission. In one of such projects, Polish Universities from Wrocław and company Balton producing stents, are engaded.
18
PL
Celem naszych badań była modyfikacja powierzchni materiału stosowanego na stenty, jakim była stal medyczna AlSl 316L. Modyfikacja związana była z naniesieniem na materiał warstwy diamentowej wytworzonej w plazmie wysokiej częstotliwości pod obniżonym ciśnieniem RF PCVD. Po naniesieniu warstwy zostały przeprowadzone badania właściwości mechanicznych stali 316L. Pozwoliły one sprawdzić, czy zmieniają się właściwości tego materiału i czy może on być po takiej modyfikacji nadal stosowany na stenty.
EN
The aim of investigations was surface modification of material used for stent medical stainless steel AlSl 316L. The modification was connected with coating the materials diamond layers manufactured by radio frequency plasma chemical vapour deposition process (RF PCVD). After the layers manufacturing the investigations of mechanical properties will be carried out. They have given the answer how the properties of material surface change and after modification used for stents still.
19
Content available remote Biomateriały metaliczne z warstwami pasywno-węglowymi dla kardiologii zabiegowej
PL
W pracy przedstawiono zakres badań, który zdaniem autorów pozwoli na kompleksową ocenę przydatności klinicznej zaproponowanej postaci użytkowej stentu wieńcowego z naniesioną warstwą pasywno-diamentową. Badania obejmują etap optymalizacji cech geometrycznych stentu wieńcowego i własności mechanicznych biomateriału metalicznego, badania odporności korozyjnej w warunkach symulujących środowisko tkankowe oraz badania w tkankach zwierząt doświadczalnych. Autorzy prognozują, że uzyskane już doświadczenia badawcze, interdyscyplinarne umożliwią opracowanie nowej postaci użytkowej stentu wieńcowego.
EN
The paper presents the program of the investigations that will be carried out to develop a new design of the coronary stent with the passive-carbon layer applied. Basing on the clinical experiennces gathered so far, the working properties of stents will be identified (geometrical properties, optimum metallic biomaterial, as well as the physical and chemical properties of their surface). Physical models of stents will be developed and the stress and strain state will be determined for the stationary boundary conditions that will make it possible to select the mechanical prperties of the metallic materials. Stent manufacturing technology will be developed and technology of refining their surface to improve their corrosion resistance, and therefore, to improve their biotolerance in contact with blood and artery wells. For refining the stent surfaces, techniques will be used that were developed by the authors within the framework of their research projects on implants for the osteous surgery (electrolytic polishing, chemical passivation, coating with the passive-carbon layers). Manufactured stents will be tested "in vitro" in the simulated laboratory conditions and subjected to verification in the tissues of the laboratory animals. To evaluate their quality, methods will be used that make it possible to determine the biochemical characteristics of stents, resistance of the metallic biomaterials to corrosion (pitting, crevice, and fatigue corrosion) and of their bio-tolerance (angiography, histopathological, and morphometric tests, as well as their hemocompatibility).
first rewind previous Strona / 1 next fast forward last