EN
As science keeps evolving over time, new solutions are being put forward for reducing structural damage. One such solution is the use of seismic isolation systems. Seismic isolation systems reduce the response of structures to the force of earthquakes by reducing the input (force) acceleration when the natural period of the structure increases. Therefore, the use of seismic isolation systems is recommended in the analysis of diverse structures. This study was carried out on seismically isolated buildings with 8, 10, and 12 regular steel floors, modeled by a non-linear isolator in two-, or three-second periods. The differences in data and the responses of the buildings were compared with fixedbase buildings with 8, 10, and 12 floors.
2
Content available Energy efficiency of steel buildings
EN
The aim of this paper is to investigate the environmental credentials of steel buildings and to present the environmental impact categories and values in a steel housing activity through a case study of steel office building. In this framework, a life cycle assessment (LCA) methodology was applied, which provides an understanding of the overall environmental performance of a housing construction. The relative influence of the service lives of different building components compared to the energy use of the buildings with a different energy efficiency is presented. As the analysis showed, recycling of construction waste becomes a critical issue, which can ensure a number of environmental benefits. The aim of this research activity was also to point out the need for an integrated approach in the design process, combining environmental performance assessment with structural calculations. Environmental impact assessment of the construction activity was carried out, following the inventory listing, in order to reach to useful conclusions on the environmental study of the project. Although steel and concrete proved to be responsible for the negative environmental impacts the ability of reuse and recyclability of steel has decreased the negative impacts of steel construction on environmental burdens.
PL
Metodę wzmacniania konstrukcji obiektów kubaturowych powinno się dobierać m.in. w zależności od gatunku stali, z jakiej ta konstrukcja została wykonana.
EN
The problem of reconstruction of existing steel buildings will be presented in an article series, which will describe aspects and issues that are important from the point of view of a correctly and rationally led building reconstruction, according to the currently binding law and to the author’s personal experience.
PL
Obecnie na rynku krajowym jest duże zapotrzebowanie na modernizację, remonty lub przebudowy istniejących obiektów kubaturowych. Przy sprawdzaniu stanów granicznych konstrukcji przydatna jest metoda pozwalająca wykorzystać rezerwy plastyczne istniejących układów konstrukcyjnych. W tym celu przydatna jest metoda wykorzystania nie tylko rezerwy plastycznej przekroju, lecz także rezerwy plastycznej dla całego układu konstrukcyjnego.
EN
The problem of reconstruction of existing steel buildings will be presented in an article series, which will describe aspects and issues that are important from the point of view of a correctly and rationally led building reconstruction, according to the currently binding law and to the author’s personal experience.
PL
Problematyka przebudowy istniejących stalowych obiektów kubaturowych podjęta zostanie w cyklu kilku artykułów. Poruszone zostaną aspekty i problemy, które zdaniem autora są istotne z punktu widzenia prawidłowo i racjonalnie przeprowadzonej przebudowy obiektu, zgodnie z obowiązującymi przepisami technicznymi i własnymi doświadczeniami.
EN
The problem of reconstruction of existing steel buildings will be presented in an article series, which will describe aspects and issues that are important from the point of view of a correctly and rationally led building reconstruction, according to the currently binding law and to the author’s personal experience.
6
Content available remote Causes of imminent failure damage and repair of steel building purlins
EN
A systemic design of purlins made from Z-sections (cold-formed from sheet metal) and their ties (made from solid bars) had been adopted in the investigated steel building. A periodic survey of the latter's technical condition showed that the purlins were deformed, bent and twisted and the ties were buckled. The condition of the roof deck supporting structure posed an imminent failure hazard. This paper presents the results of investigations of the load-bearing capacity and rigidity of the roof deck supporting structure, the aim of which was to determine the causes of its imminent failure condition.
PL
W artykule zaprezentowano metody oceny nośności nowoczesnych konstrukcji hal łukowych stosowanych w budownictwie rolniczym. Cienkościenne łukowe blachy stalowe są proste w montażu, łatwe w eksploatacji i tańsze od tradycyjnych konstrukcji budynków rolniczych. Specyfika zadaszeń z cienkościennych blach łukowych nastręcza jednak wiele problemów projektowych. Rozwiązanie tych problemów pozwoli na wznoszenie tanich i bezpiecznych budynków. W artykule przedstawiono normatywne metody projektowania, najczęstsze błędy projektowe oraz kierunki rozwoju metod projektowania wspomaganych badaniami.
EN
The paper presents evaluation methods of arch-shaped corrugated steel roof capacity used in an agricultural construction. The arch-shaped corrugated steel roof is easy to install, to use and less expensive than the traditional construction of agricultural buildings. The specific of structure poses many design problems related to the local buckling of profiled sheets. The article presents normative design methods, the most common design errors, trends research methods and numerical calculations.
8
Content available remote Nowe wymagania dla wytwórców stalowych konstrukcji budowlanych
PL
Przedstawiono wymagania arkusza drugiego normy PN-EN 1090-2:2009 dla producentów wytwarzających stalowe konstrukcje budowlane oraz zmiany, jakie ta norma wprowadza w stosunku do obowiązującej jeszcze normy budowlanej PN-B 06200:2002. Podkreślono znaczenie posiadania przez wytwórcę zakładowej kontroli produkcji oraz rolę jednostek notyfikowanych w procesie wytwarzania konstrukcji budowlanych kończącym się wydaniem deklaracji zgodności i naniesieniem znaku CE na wyrób. Przedstawiono tok postępowania w zakładzie prowadzący do uzyskania certyfikatu dla zakładowej kontroli produkcji. Podkreślono znaczenie posiadania w zakładzie certyfikatu systemu jakości w spawalnictwie na zgodność z wymaganiami normy PN-EN ISO 3834-2:2007.
EN
There are presented the requirements for manufacturers of steel building structures specified in the PN-EN 1090-2 : 2009 and changes which are introduced by this standard in relation to the PN-B 06200:2002 standard, still binding in building engineering. It has been accentuated the importance of being in possession of the institutional department for production inspection by the fabricator and the role of notified bodies in the process of building structures fabrication which is finished in the issue of conformity declaration and in marking of the product with CE sign. The procedure resulting in the obtainment of the certificate by the institutional department for production inspection has been shown. It has been stressed also the importance of being in possession of the certificate of quality system in welding technology in accordance with PN-EN ISO 3834-2:2007 specifications.
PL
Wybuch pieca elektrycznego spowodował lokalne uszkodzenie szedowego dachu stalowej hali przemysłowej, ze strunobetonowymi płytami dachowymi rozpiętości 12,62 m. W wyniku eksplozji zostały zniszczone żebra płyt strunobetonowych, które są ich głównymi elementami nośnymi. Stan techniczny strunobetonowych płyt był awaryjny. Powstało zagrożenie zawalenia się dachu hali. Omówiono uszkodzenia dachu i sposób jego wzmocnienia.
EN
An explosion of electric furnace caused a local damage of the roof in steel industrial building. This building has a saw-tooth roof covering, constructed from pre-stressed plates with the span length of 12,62 m. The explosion caused a local damage of plate pre-stressed ribs, which are the roof main structural elements. The technical condition of the plates has been assessed as an emergency state due to the loss of the plate strength and the hazard of their fall down. The damage repair has also been presented herein.