EN
The distance relay using the transmission line impedance measurement identifies the type and location of the fault. However, any other factors that cause the failure of the measured impedance, makes the relay detect the fault in incorrect location or do not detect the fault at all. One of these factors is the fault resistance which directly increases the measured impedance by the relay. Another factor that indirectly alters the impedance of the transmission line is static synchronous compensator (STATCOM). When a fault happens, current injection by the STATCOM changes the measured signals by the relay and thus makes the calculated impedance incorrect. In this paper, a method is provided based on the combination of distance and differential protection. Firstly, from the current data of buses, faulted transmission line is detected. Then using the presented algorithm, the fault location is calculated on the transmission line. The basis of the algorithm is on the active power calculation of the buses. Fault resistance is calculated from the active powers and its effect will be deducted from calculated impedance by the algorithm. Furthermore, with choosing data of appropriate bus, STATCOM effect is eliminated, and fault location will be obtained.
EN
This article describes the problem of automatic regulation of reactive power using electronic devices FACTS (Flexible AC Transmission Systems): static synchronous compensator (STATCOM) and unified power flow controller (UPFC). With the help of a complex writing form, the following are determined: voltages at the installation nodes of the FACTS device and loads, currents of loads, power sources and electronic compensators in caseof voltage instability at the load node of the electrical network. Voltages and currents are determined using the node-voltage method. The taskof STATCOM is partial or full compensation of reactive power. During the reduction of the voltage at the load node, the reactive power generatedby the power source decreases. The STATCOM should partially or fully compensate for the reactive power imbalance as quickly as possible. However,at the same time, it is not possible to fully compensate for the voltage reduction. A series-parallel or parallel-series UPFC can be used to solvethis problem. As a result of using the UPFC, it is possible to automatically raise the voltage level to acceptable values with the help of the UPFC series compensator. The analysis shows that the parallel-serial UPFC is characterized by the stability of operation.In the case of using a series-parallel UPFC, there are restrictions on the ability to adjust the imaginary voltage component of the series compensator, since the angle ofthe voltage vector changes, which causes a failure in the operation of the regulatorof the parallel compensator UPFC.
PL
W artykule opisano problematykę automatycznej regulacji mocy biernej za pomocą urządzeń elektronicznych FACTS (Flexible AC Transmission Systems): statycznego kompensatora synchronicznego (STATCOM) oraz regulatora przepływu mocy (UPFC). Za pomocą złożonego formularza rejestracyjnego określane są: napięcia w węzłach instalacji urządzenia FACTS i obciążenia, prądy obciążenia, źródeł zasilaniai kompensatorów elektronicznych w przypadku niestabilności napięcia w węźle obciążenia siecielektrycznej. Napięcia i prądy są wyznaczane metodą napięć węzłowych. Zadaniem STATCOM jest częściowa lub pełna kompensacja mocy biernej. Podczas spadku napięcia w węźle obciążenia, moc bierna generowana przez źródło zasilania maleje. STATCOMpowinien częściowo lub w pełni skompensować nierównowagę mocy biernej tak szybko,jak to możliwe. Jednocześnie jednak nie jest możliwe pełne skompensowanie spadku napięcia. W celu rozwiązania tego problemu można zastosować szeregowo-równoległy lub równoległo-szeregowy układ UPFC. W wyniku zastosowania UPFC możliwe jest automatyczne podniesienie poziomu napięcia do akceptowalnych wartości za pomocą kompensatora szeregowego UPFC. Analiza pokazuje, że równoległo-szeregowy UPFC charakteryzuje się stabilnością działania. W przypadku zastosowania szeregowo-równoległego UPFC istnieją ograniczenia w zakresie możliwości regulacji składowej urojonej napięcia kompensatora szeregowego, ponieważ zmienia się kąt wektora napięcia, co powoduje awarię działania regulatora kompensatora równoległego UPFC.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.