Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 40

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  stal ocynkowana
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
Purpose: Generally, laser cutting processes aim to cut materials with high accuracy, as well as precise and near-perfect sizes and results. The purpose of this study is to evaluate the roundness quality of the holes cut by laser cutting on galvanised steel plates; two variations are given, such as cutting speed and nozzle diameter. Design/methodology/approach: The type of laser used is a fibre laser. The material used is galvanized steel with a thickness of 3 mm with dimensions of 200 mm in length and 200 mm in width. A round profile is good if the distance between the points of the geometric shape is the same distance from the centre point. Findings: The measurement results show that the smallest radius deviation is with an average value of 20.08 mm at a nozzle diameter of 2.5 mm and a cutting speed of 3 m/min, close to the initial radius value of 20.00 mm. Research limitations/implications: During the laser cutting process, The best roundness quality is the combination of a nozzle diameter of 2.5 mm and a cutting speed of 3 m/min with a small deviation (the index deviation is 0.4%). At the same time, the biggest deviation in this experiment is the combination of parameters with a nozzle diameter of 3 mm and a cutting speed of 4 m/min (the maximum deviation value is 1%). Practical implications: The use of the proposed nozzle diameter and cutting speed approach is an important requirement for industrial applications with laser cutting to get the right product for its intended use. Originality/value: This article presents different nozzle diameters and cutting speeds to reveal the roundness quality due to these variations, where the roundness quality will be adapted for a particular application.
EN
Purpose: This paper investigates the possibility of successfully welding a Low Alloy Steel (LAS) stud to Galvanized Steel (GS) plate. Design/methodology/approach: Arc Stud Welding (ASW) was performed on joining LAS studs to GS plates. Welding parameters were selected based on weld trails. The first tests of the welded joints were based on visual inspection for welding defects such as lack of fusion and undercut welding defects. The good quality should be free of these defects and have full weld reinforcement. Other weld qualifications included torque strength test, microhardness test, and microstructure examination. Findings: The LAS studs have been successfully welded to a galvanized steel plate using the arc stud welding process. Higher welding current with adjusted welding time (800 A, 0.3 s) gave full weld reinforcement, the best joint appearance, and strength. Martensite phase was detected in the weld area and heat affected zone (HAZ), affecting the joint mechanical properties. Hardness property varied across the welded joint, and maximum hardness was recorded at the HAZ at the stud side. Hardness increased with the increasing welding current. At 800 A, welding current hardness was 10% higher than at 400 and 600 A. Torque strength was affected by weld reinforcement, and 800 A gave the best weld reinforcement that produced the highest torque strength. Research limitations/implications: The main research limitation is the difficulty of welding LAS studs and GS plates. In conventional welding methods, such as gas metal arc welding, it is hard to get full weld penetration due to the geometry restrictions of the joint, which results in partial weld penetration between the studs and the plates. Furthermore, the issue of zinc evaporation during welding can be reduced by the advantage of the very high welding speed (in milliseconds) of ASW that overcomes the problem of continuous welding that usually results in the formation of harmful porosities and poor weldability. Originality/value: In this research, galvanized steel plates were successfully welded to LAS studs using the ASW process. The welding parameters for this dissimilar welding joint were carefully selected. Microstructure changing due to the welding process was investigated. The joint mechanical properties were evaluated.
EN
Metals constitute some of the major materials for making water delivery pipelines. However, the service life of metallic pipelines is affected by corrosion. Mild Steel (MS), Galvanized Steel (GS) and Copper were selected based on their strength and corrosion resistance. They were subjected to Potentiodynamic Polarization (PP) and Electrochemical Impedance Spectroscopy (EIS) investigations using water as the electrolyte from selected sampling points (A, B, C, D and E) on the University of Lagos, Akoka water distribution network. Corrosion current density (Icorr) and Impedance (Z) were measured in A/mm2 and ohms respectively. The morphology of the corroded samples was examined using Scanning Electron Microscope (SEM). The result obtained from PP investigation showed Icorr in the low range for the three metals considered. Similarly, for EIS, Z values measured were high for MS, GS and Cu. Both methods indicated that Cu was the most corrosion resistant material, closely followed by GS and lastly MS. The SEM images clearly showed that among the three specimens, the morphology of Cu remained unaffected by the environment. On the other hand, MS and GS showed evidences of corrosion with pits. The large amounts of iron established in the studied water distribution system, confirmed corrosion of water pipes.
PL
Metale są jednym z głównych materiałów konstrukcyjnych wodociągów. Jednak trwałość metalowych rurociągów jest ograniczona ze względu na korozję. Ze względu na wytrzymałość i odporność na korozję do budowy rurociągów stosuje się stal miękką (MS), stal ocynkowaną (GS) i miedź. Próbki pobrane w wybranych miejscach (A, B, C, D i E) sieci wodociągowej Akoka poddano na Uniwersytecie w Lagos badaniom metodą polaryzacji potencjodynamicznej (PP) i elektrochemicznej spektroskopii impedancyjnej (EIS) z zastosowaniem wody jako elektrolitu. Gęstość prądu korozyjnego (Icorr) i impedancję (Z) zmierzono odpowiednio w A/mm2 i omach. Morfologię skorodowanych próbek zbadano za pomocą skaningowego mikroskopu elektronowego (SEM). Wynik otrzymany w badaniach PP wykazał Icorr w niskim zakresie dla trzech rozważanych metali. Podobnie w przypadku EIS zmierzone wartości Z były wysokie dla MS, GS i Cu. Obie metody wskazywały, że miedź jest najbardziej odpornym na korozję materiałem, a następnie ocynkowana stal o podobnych właściwościach i na końcu stal miękka. Na mikrofotografiach SEM wyraźnie widać, że spośród trzech próbek metali środowisko nie miało wpływu na morfologię Cu. MS i GS wykazały ślady korozji z wżerami. Duże ilości żelaza stwierdzone w badanym systemie wodociągowym potwierdziły korozję rur.
EN
This paper presents an FEM analysis of the V-die bending process of a zinc plated DC01 steel. The article presents a new approach to the analysis of the coated sheets bending process as simulation studies are not commonly used in this field, and most investigations concern experimental analyses. The process is analyzed in terms of maximum plastic strain and the reaction force on the punch. An analysis of the spring-back phenomenon was conducted. This paper shows the model preparation process as well as the results achieved and their interpretation. It has been shown that the coating layer thickness affects the bending reaction force acting on the punch as well as the scale of the springback phenomenon. The magnitude of the maximum plastic strain is also affected by the coating thickness.
EN
The paper presents the evaluation of the brazing capabilities of the multi-beam Trifocal laser joint system made of galvanized steel DX51D with a thickness of 3 mm, covered with a protective coating of Magnelis type. The brazed joints obtained have been subjected to metallographic, strength and corrosion resistance tests in the Ascott CCIP450 salt cell. The tests have shown that there is a certain range of brazing process parameters that allow to make the correct overlap joints of high quality with small welding distortions and a narrow heat affected zone. The obtained joints are characterized by a slightly worse corrosion resistance than the basic material, and zinc evaporation by means of additional low-power laser beams improves the solder's flow.
PL
W pracy przedstawiono ocenę możliwości lutospawania wielowiązkowym systemem laserowym Trifocal złączy zakładkowych ze stali ocynkowanej DX51D o grubości 3 mm, pokrytej powłoką ochronną typu Magnelis. Uzyskane złącza lutospawane zostały poddane badaniom metalograficznym, wytrzymałościowym oraz badaniom odporności korozyjnej w komorze solnej Ascott CCIP450. Przeprowadzone badania wykazały, że istnieje zakres parametrów procesu lutospawania pozwalający na wykonywanie poprawnych złączy zakładkowych charakteryzujących się wysoką jakością z niewielkimi odkształceniami spawalniczymi oraz wąską strefą wpływu ciepła. Uzyskane złącza charakteryzują się minimalnie gorszą odpornością korozyjną od materiału podstawowego, a odparowanie cynku przy pomocy dodatkowych wiązek laserowych niskiej mocy poprawia rozpływność lutu.
PL
Nieustannie rosnące wymagania co do trwałości eksploatacyjnej i odporności na korozję sprawiły, że w dzisiejszym przemyśle samochodowym ważną rolę odgrywają stalowe blachy karoseryjne pokryte cynkiem. Charakteryzują się one bardzo wysokimi właściwościami mechanicznymi a co najważniejsze - dzięki pokrywaniu tych blach cynkiem – wysoką odpornością na korozję.
PL
W artykule przedstawiono mało znany w kraju sposób zabezpieczania przed korozją stalowego zbrojenia konstrukcji betonowych metodą cynkowania ogniowego. Na wstępnie omówiono mechanizm ochrony antykorozyjnej powierzchni stalowych prętów w środowisku cieczy porowej betonu przez powłokę cynkową. Następnie w zarysie opisano technologię cynkowania ogniowego w odniesieniu do prętów zbrojeniowych. Zwrócono uwagę na korzystny wpływ powłoki cynkowej na przyczepność zbrojenia do betonu. Opisano mechanizm degradacji powłoki spowodowany oddziaływaniem wysokoalkalicznej cieczy porowej, a także wnikaniem chlorków i dwutlenku węgla w porowatą strukturę betonu.
EN
The article presents the method of corrosion protection of steel reinforcement of concrete structures by hot dip galvanizing, which is not well-known in Poland. The mechanism of protection against corrosion of steel rebars surface in the concrete pore liquid environment by zinc coating is discussed in the preliminary part. Then the hot dip galvanizing technology for reinforcing bars is outlined. Attention was drawn to the positive influence of zinc coating on the adhesion of reinforcement to concrete. The mechanism of coating degradation caused by the action of high alkaline pore liquid, as well as penetration of chlorides and carbon dioxide into porous concrete structure was described.
8
Content available remote Technologie przygotowania powierzchni elementów ocynkowanych
PL
Powłoki Duplex są dzisiaj najlepszym zabezpieczeniem elementów konstrukcji stalowych, gwarantującym długotrwałą ich eksploatację w najtrudniejszych warunkach atmosferycznych. Przed pokryciem powierzchni ocynkowanej powłoką malarską stosuje się najczęściej obróbkę strumieniowo-ścierną, której celem jest usunięcie zanieczyszczeń, warstwy tlenkowej, a także zwiększenie przyczepności poprzez wzrost chropowatości podłoża. W przypadku malowania elementów cienkościennych zastosowanie obróbki strumieniowo-ściernej jest niemożliwe. W tych przypadkach stosowane są różne chemiczne obróbki powierzchni, których zadaniem jest wytworzenie powłoki konwersyjnej gwarantującej zarówno dobrą przyczepność powłoki lakierowej do podłoża, jak i wieloletnią ochronę antykorozyjną. W artykule przedstawiono przegląd technologii chemicznej obróbki powierzchni możliwych do zastosowania pod powłoki Duplex.
EN
Duplex coatings are today best protection of steel construction elements, guaranteeing their long-term exploitation in the harshest weather conditions. Before covering the galvanized surface by paint coating abrasive blasting is most commonly used, which aims is to remove impurities, the oxide layer and increase adhesion by growth of surface roughness. In the case of painting thin-walled components application of abrasive blasting is not possible. In these cases, there are used various chemical surface treatments, whose task is to produce a conversion coating that ensures both a good adhesion of the paint coating to the substrate, and long-term corrosion protection. This lecture presents an overview of chemical surface treatment technologies, possible to apply for Duplex coatings.
9
PL
Przedstawiono problem wadliwości zabezpieczenia antykorozyjnego w zakresie malarskich powłok ochronno-dekoracyjnych wykonywanych na stalowych elementach barier zabezpieczonych uprzednio poprzez ocynkowanie metodą zanurzeniową na gorąco. Wykorzystując przykłady pochodzące z różnych obiektów przedstawiono powtarzający się problem delaminacji powłok malarskich, niezależny od rodzaju zastosowanych wyrobów lakierniczych oraz znacznego rozwoju korozji na odsłanianym podłożu cynkowym. Zwrócono również uwagę na przypadki nieprawidłowości dotyczące tych samych elementów, ale związane z brakiem właściwego nadzoru w czasie realizacji robót antykorozyjnych.
EN
The problem of defective corrosion protection concerning paint, protective and decorative coatings of steel barriers elements, made on hot dip galvanized coating, is presented in the paper. Examples taken from various objects represent a recurring problem of the coating system delamination, regardless of the nature of the paint products and resulting with significant growth of corrosion on the zinc surface. Attention was also drawn to other cases of irregularities concerning the same elements, but occurring due to lack of proper supervision during the execution of corrosion protection works.
PL
W artykule przedstawiono wyniki badań dotyczących przyczyn pękania lutospoin w różnoimiennych złączach zakładkowych wykonanych laserem diodowym dużej mocy ROFIN DL 020 z użyciem materiału dodatkowego w postaci proszku aluminium, na przykładzie łączenia cienkiej blachy aluminiowej z blachą stalową pokrytą elektrolitycznie powłoką cynkową. Przedstawiono wyniki badań metalograficznych makroskopowych i mikroskopowych. Wskazano na problemy oraz przedstawiono sugestie dotyczące technologii lutospawania laserowego materiałów znacznie różniących się własnościami fizycznymi i składem chemicznym.
EN
A study on cracking phenomena during laser braze welding of dissimilar lap joints between aluminum thin plate and galvanized low carbon sheet steel is described. The experiments were carried out using a high power diode laser Rofin DL020 and aluminum powder as filler metal. Macro and microstructure analysis of the joints were analysed. Issues and problems in laser braze welding of materials having different chemical composition and physical properties are presented.
PL
W artykule przedstawiono wyniki badań dotyczących skłonności do tworzenia się pęknięć w lutospoinach złączy zakładkowych cienkich blach aluminiowych i karoseryjnych blach stalowych obustronnie galwanizowanych cynkiem, które wykonywano laserem diodowym dużej mocy (HPDL) ROFIN DL 020 oraz łukowo metodą CMT z użyciem materiału dodatkowego odpowiednio w postaci proszku i drutu litego. Przedstawiono wyniki badań metalograficznych makroskopowych i mikroskopowych, rentgenografii strukturalnej, mikroanalizy rentgenowskiej EDS oraz pomiarów twardości. Wskazano na przyczyny powstawania w lutospoinach na osnowie aluminium, złączy różnoimiennych typu aluminium - ocynkowana stal niestopowa, kruchych faz międzymetalicznych typu Fe-Al.
EN
In this article results of studies on cracks formation susceptibility in braze-welded joints of thin aluminum sheets and double-sided zinc galvanized steel sheets for car body parts made by laser brazing with high power diode laser ROFIN DL 020 and CMT MIG-brazing, with filler material in form of powder and wire accordingly, were presented. Results of macro- and microscopic metallographic examinations, structural roentgenography, EDS microanalysis and hardness tests were presented. Causes of brittle intermetallic Fe-Al phases formation in Al-matrix filler metal in dissimilar aluminum - zinc plated carbon steel joints were pointed.
PL
W trzyczęściowym artykule przedstawiono zagadnienia związane z korozją konstrukcji stalowych. W części II omówiono zabezpieczenia przeciwkorozyjne.
EN
The three-part article presents the issues related to corrosion of steel structures. In the second part discussed anticorrosion protection.
EN
The aim of the study was to determine the possibility of joining dissimilar joints of zinc coated E275D and X5CrNi18-10 steels by braze welding process. The experiment was performed by the Puls-Arc method with argon as the shielding gas. The process was carried out using a Lincoln Electric Power Wave S500 welding device. Joints was carried out in two variants: without treatments before braze welding, and when the zinc coating was removed by mechanical means. Macro- and micro metallographic examinations and an analysis of mechanical properties of joints based on Vickers hardness distribution were carried out. The average hardness of the welds is 99 HV10. No effect on hardness of the removal of the zinc coating before braze welding was observed. For welds in the presence of a liquid metal, LME (Liquid Metal Embrittlement) cracks were observed. The results may be useful in the design of dissimilar materials joining technology using braze welding method.
PL
Celem badań było określenie możliwości łączenia złączy różnoimiennych z ocynkowanej stali E275D i stali X5CrNi18-10 metodą lutospawania. Eksperyment wykonano łukiem pulsującym w osłonie argonu. Proces przeprowadzono na urządzeniu Power Wave S500 firmy Lincoln Electric. Złącza wykonywano w warunkach bez dodatkowych zabiegów przed procesem i gdy w miejscu złącza usunięto warstwę cynku w sposób mechaniczny. Zaprezentowano wyniki badań makro- i mikroskopowych złączy oraz analizę ich właściwości mechanicznych wykonaną w oparciu o rozkład twardości w złączu. Pomiary prowadzono sposobem Vickersa. Średnia twardość w złączu wynosi 100 HV10. Nie stwierdzono wpływu usuwania powłoki cynkowej na twardość w złączach. W złączach zaobserwowano pęknięcia spowodowane kruchością w obecności ciekłych metali. Uzyskane wyniki mogą być przydatne podczas projektowania technologii łączenia materiałów różnoimiennych przy użyciu metody lutospawania.
PL
Przedstawiono trudności związane z łączeniem elementów ocynkowanych oraz omówiono wpływ cynku na przebieg procesu spawania i lutospawania elektrodą topliwą w osłonie gazów. Omówiono sposoby minimalizacji szkodliwego oddziaływania cynku na jakość połączeń. Przedstawiono jakość, własności i budowę strukturalną połączeń spawanych i lutospawanych blach stalowych.
EN
Difficulties connected with joining of zinc coated steel components and the influence of zinc on gas metal arc welding and weldbrazing processes have been presented. Minimization methods of zinc harmful effect on quality of joints have been discussed. Quality, properties and structure of welded and weldbrazed joints have been presented.
PL
W artykule zaprezentowano innowacyjną technologię spawania elektrodą topliwą w osłonie gazów aktywnych (MAG) prądem z regulowaną ilością składowej ujemnej. Zbadano wpływ udziału składowej ujemnej w przebiegu prądu spawania (Electrode Negative Ratio, EN Ratio) i napięcia łuku na strukturę stali z powłokami ochronnymi cynkowymi i cynk – żelazo.
EN
The development of modern GMA welding variants is related to the search for the appropriate methods for joining advanced engineering materials, often thin and sensitive to heat effect (e.g. coated steels, aluminum and magnesium alloys, nickel alloys). The researchers of the Gliwice-based Instytut Spawalnictwa have carried out detailed technological tests of variable polarity AC GMA welding of thin steel plates provided with protective coatings [1, 2]. The tests demonstrated that the use of variable polarity AC makes it possible to obtain joints characterised by good quality and aesthetic appearance. Modern welding devices (such as OTC Daihen-manufactured DW 300 or Cloos-made Qineo Champ), using synergic lines with variable course of parameters, enable their users to produce butt, overlap and T-shaped joints of 0.8 mm-thick plates.
16
Content available remote Adhesion of organic coatings to hot-dip galvanized steel
EN
Duplex systems provide long-time corrosion protection, much longer than the sum of the lifetimes of zinc and paint used individually. However loss of adhesion between coating and zinc substrate is often found in practice. Different methods of zinc surface preparations are used in the field. The aim of this study was to examine and compare coating protection when the old zinc surface, stored during long-time period (15 years) in laboratory conditions, was painted. Adhesion and impedance studies using epoxy coating systems on galvanized steel substrate, which had been prepared by different methods, were performed.
PL
System duplex zapewnia długoletnią ochronę stali przed korozją, znacznie dłuższą niż sumaryczny okres ochrony zapewniany osobno przez powłokę cynkową i zestaw powłokowy. Jednakże, w praktyce często spotyka się utratę przyczepności pomiędzy powłoką a podłożem cynkowym. Stosuje się różne sposoby przygotowania powierzchni cynku przed zastosowaniem powłoki ochronnej. Celem niniejszej pracy było zbadanie i porównanie właściwości ochronnych powłoki nałożonej na starą powierzchnię cynku, przechowywaną przez długi okres czasu (15 lat) w warunkach laboratoryjnych. Wykonano badania przyczepności oraz impedancyjne powłoki epoksydowej na podłożu stali ocynkowanej zanurzeniowo, przygotowanej przez użyciu różnych metod.
17
Content available remote Czy tak musi być? Cz.2 - kilka przykładów
PL
W pracy przedstawiono przyczyny i skutki zniszczenia ocynkowanych rur stalowych stosowanych w systemach rozprowadzania i magazynowania ciepłej i zimnej wody. Stwierdzono, że zaobserwowana korozja rur jest wynikiem zarówno sposobu nakładania powłoki cynkowej, technologii montażu rur, jak i jakości wody wodociągowej i sposobu jej oddziaływania.
EN
This article describes the causes and effects of damage to galvanized steel pipes used in systems for the distribution and storage of hot and cold water. It is concluded that the causes of observed pipe corrosion may include the method of galvanization, the technology used for pipe installation, the quality of the water and the way in which it acts on the pipes.
20
Content available remote Nowoczesne metody lutospawania
PL
Opisano podstawy procesu lutospawania i przedstawiono wyniki prób technologicznych łączenia elementów aluminiowych z elementami stalowymi ocynkowanymi ogniowo z wykorzystaniem spoiwa wysokocynkowego oraz łączenia elementów stalowych ocynkowanych ogniowo z elementami ze stali wysokostopowej odpornej na korozję z wykorzystaniem spoiwa brązowego w postaci drutu proszkowego. Analizowano wyniki badań wytrzymałości na rozciąganie uzyskanych połączeń oraz badań metalograficznych makro- i mikroskopowych. Wyniki badań wykazały, m.in., możliwość uzyskania wytrzymałych połączeń różnoimiennych pomiędzy elementami aluminiowymi a stalowymi ocynkowanymi bez uszkodzenia warstwy cynku.
EN
It has been described the essentials of the braze welding. There are also described the results of technological investigations on the possibility of joining of hot galvanized aluminum elements with the use of filler metals with high zinc content and joining of hot galvanized elements and stainless steel with the use of brass flux cored wire. There are also presented the results of tensile tests and macroscopic and microscopic metallographic examination. The results have shown, among others, the possibility of obtainment of resistant dissimilar joints between aluminum and steel elements, without a damage of zinc coating.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.