Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 31

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  stabilność napięciowa
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
Technological developments in the deregulated electricity market enable competitive environment for Distribution Companies (DISCOs) and DGs to maintain reliable, effective and secure electrical power to the consumers. The performance of the DISCOs in radial distribution networks is primarily relied upon the power loss and voltage stability. Best practice to mitigate the losses in the distribution network includes capacitor placements, induction of DGs and network reconfigurations. These process help out to improve the system voltage profile and minimize the power losses and thereby maximising the profit of the distribution companies. In this paper, recently developed and comprehensive moth flame optimization algorithm is presented for maximizing the profit of the DISCOs under competitive environment. The execution process of network reconfiguration and proper placement and sizing of capacitors and DG units are taken care of by MFO algorithm. Reconfiguration of network is a mechanism of shuffling existing pattern of feeders duly changing ON and OFF status of tie-line switches to improve the performance of the DISCOs. The algorithm also minimizes the various types of cost such as investment, maintenance and operational cost. The proposed MFO algorithm is implemented on IEEE 33 node and 69 node systems to evaluate its performance. Evaluation of solution in MATLAB software demonstrates the skills of MFO in DISCOs.
PL
Rozwój technologiczny na zderegulowanym rynku energii elektrycznej umożliwia konkurencyjne środowisko dla spółek dystrybucyjnych (DISCO) i dyrekcji generalnych w celu utrzymania niezawodnej, efektywnej i bezpiecznej energii elektrycznej dla konsumentów. Wydajność DISCO w promieniowych sieciach rozdzielczych zależy przede wszystkim od strat mocy i stabilności napięcia. Najlepsza praktyka łagodzenia strat w sieci dystrybucyjnej obejmuje rozmieszczenie kondensatorów, indukcję DG i rekonfiguracje sieci. Procesy te pomagają poprawić profil napięciowy systemu i zminimalizować straty mocy, a tym samym maksymalizować zysk spółek dystrybucyjnych. W niniejszym artykule przedstawiono niedawno opracowany i kompleksowy algorytm optymalizacji płomienia ćmy w celu maksymalizacji zysku DISCO w konkurencyjnym środowisku. Procesem wykonania rekonfiguracji sieci oraz właściwego rozmieszczenia i doboru kondensatorów i jednostek DG zajmuje się algorytm MFO. Rekonfiguracja sieci to mechanizm tasowania istniejącego wzorca linii zasilających, odpowiednio zmieniający stan ON i OFF przełączników linii łączącej w celu poprawy wydajności dysków DISCO. Algorytm minimalizuje również różnego rodzaju koszty, takie jak koszty inwestycyjne, konserwacyjne i operacyjne. Proponowany algorytm MFO jest zaimplementowany w systemach IEEE 33 węzłów i 69 węzłów w celu oceny jego wydajności. Ocena rozwiązania w oprogramowaniu MATLAB demonstruje umiejętności MFO w dyskotekach.
EN
The article covers selected issues related to the share of hydroelectric power in the process of rebuilding the power system after black-out and voltage regulation during that process. Selected results of measurements made during the creation of the transmission chain for the need to start a block of a thermal power plant from a hydroelectric power plant were presented.
PL
Artykuł obejmuje wybrane zagadnienia związane z udziałem elektrowni wodnych w procesie odbudowy systemu elektroenerge- tycznego po blackoucie oraz regulacji napięcia w czasie trwania tego procesu. Przedstawiono wybrane wyniki pomiarów dokona- nych w czasie tworzenia ciągu przesyłowego na potrzeby uruchamiania bloku elektrowni cieplnej z elektrowni wodnej.
EN
The paper presents the problem of interaction between an LCC HVDC system and a VSC HVDC system. It was shown that the separate operation of an LCC HVDC system under low short circuit power conditions is possible and that at this level of short circuit power it is possible to transfer the same active power through the VSC HVDC system operating in parallel, under the condition that the inverter of this connection operates in AC voltage regulation mode. On the other hand, in certain circumstances it is this mode that may cause the LCC system operating conditions to worsen, which indicates the need for a careful analysis of such cases in order to properly adjust the settings of the relevant control systems. It has been shown that the settings of the voltage regulation system and the PLL system under normal short circuit power conditions can improve the process of the LCC HVDC system returning to operation post-disturbance, while in the conditions of reduced short circuit power they make this process more difficult.
PL
W artykule przedstawiono problem interakcji pomiędzy układem LCC HVDC a VSC HVDC. Pokazano, że samodzielna praca układu LCC HVDC w warunkach niskiej mocy zwarciowej jest możliwa oraz że przy tym poziomie mocy zwarciowej możliwe jest dodatkowe wyprowadzenie takiej samej mocy czynnej przez równolegle pracujący układ VSC HVDC, pod warunkiem że falownik tego łącza będzie pracował w trybie regulacji napięcia AC. Z drugiej strony w określonych okolicznościach to właśnie ten tryb może być przyczyną pogorszenia warunków pracy układu LCC, co wskazuje na potrzebę dokładnej analizy takich przypadków w celu właściwego doboru nastaw odpowiednich układów regulacji. Pokazano bowiem, że nastawy układu regulacji napięcia i układu PLL w warunkach normalnej mocy zwarciowej potrafią usprawnić proces powrotu do pracy układu LCC HVDC po zakłóceniach, natomiast w warunkach obniżonej mocy zwarciowej ten proces utrudniają.
PL
Analiza wybranych zagadnień równoległej pracy dwóch układów przesyłowych prądu stałego (HVDC) o odmiennych technologiach, tj. układu tyrystorowego (LCC – Line Commutated Converter) i tranzystorowego (VSC – Voltage Source Converter) jest przedmiotem niniejszego referatu. Pokazano, że równoległa praca układów jest możliwa w warunkach niskiej mocy zwarciowej tam, gdzie sam układ LCC o równoważnej mocy nie mógłby pracować stabilnie w trybie regulacji mocy. Warunkiem jest praca falownika łącza VSC HVDC w trybie regulacji napięcia AC. Z drugiej strony w określonych okolicznościach to właśnie ten tryb może być przyczyną pogorszenia warunków pracy układu LCC, co wskazuje na potrzebę dokładnej analizy takich przypadków celem właściwego doboru nastaw odpowiednich układów regulacji.
EN
This paper describes the results of an analysis of selected problems in the parallel operation of two HVDC systems based on different technologies, namely Line Commutated Converter (LCC HVDC) and Voltage Source Converter (VSC HVDC). Using Maximum Power Curves (MPC) technique it is shown that the parallel operation of the two systems in low short circuit power conditions is possible where a single LCC HVDC scheme of equivalent rated power would fail to operate stably in constant power mode. However, the prerequisite for such operation is active AC voltage control offered by the VSC inverter. It is also shown that the positive influence of the VSC converter is noticeable if the two inverters are a considerable distance apart (e.g. 100 or 200 km). On the other hand, EMTP simulations reveal also adverse effects of the mutual influence, particularly apparent in low ESCR systems where the so-called voltage and power instability problem of the AC/DC systems is be more evident. This phenomenon is the basic cause of the undesirable interaction between the LCC HVDC and VSC HVDC resulting in more difficult return to nominal operating conditions after a commutation failure in the LCC system. The proposed and demonstrated solution is to tune down the PLL and voltage controller gains in order to make the overall system less stiff.
PL
W artykule przedstawiono podstawowe pojęcia związane ze stabilnością napięciową węzła sieci. Przeanalizowano wpływ regulacji przełącznika zaczepów transformatora na stabilność napięciową. Opracowano wytyczne dla regulatora przełącznika zaczepów ze względu na krytyczne możliwe obniżenie się zapasu stabilności napięciowej.
EN
The paper presents the basic concepts associated with the stability of the voltage. The influence of regulating transformer on the voltage stability. Developed guidelines for the regulator tap changer due to a critical decrease in the supply voltage stability.
PL
Przedstawiono doświadczenia z wykorzystania aparatury pomiarowej typu DA BOX 2000 do badania parametrów jakości energii elektrycznej oraz stanów dynamicznych w wybranych lokalizacjach sieci dystrybucyjnej.
EN
The paper presents experience gained using measurement equipment type DA BOX 2000 in testing electric energy quality and dynamic states in selected locations of distribution network.
PL
Niniejsza praca prezentuje możliwości wykorzystania farm wiatrowych (FW), pracujących ze zmienną rezerwą wirującą, do poprawy stabilności napięciowej dynamicznej. Porównuje przebiegi wartości napięć węzłowych w funkcji czasu w dwóch przypadkach pracy generatorów wiatrowych.
EN
In the submitted paper the real-time analysis of WF, including variant with reduced real power (emergency mode), impact on EPS are presented. The tested study case shows the potential of the proposed method in short term voltage stability improvement.
PL
W artykule przedstawiono wpływ niskich poziomów napięć na funkcjonowanie newralgicznych odbiorników układów potrzeb własnych wybranych bloków wytwórczych pracujących w KSE. Określono graniczne czasy pracy dla tych odbiorników przy niskich poziomach napięć w KSE oraz dopuszczalne, zaniżone poziomy napięć w obwodach wtórnych układów potrzeb własnych rozpatrywanych bloków wytwórczych, przy których blok wytwórczy jest w stanie współpracować z systemem elektroenergetycznym. Zaproponowano sposoby modernizacji układów potrzeb własnych umożliwiające współpracę bloku wytwórczego z KSE przy znacznie zaniżonych napięciach w systemie elektroenergetycznym.
EN
The paper presents the effect of low voltage levels on the operation of critical receivers in auxiliary systems of chosen generating units working in the Polish National Power System. Time limits were specified for these receivers at conditions of low voltage levels in the Polish National Power System and acceptable, understated voltage levels in secondary circuits of auxiliary systems of generating units. The possible problems which might be observed in internal power plant infrastructure were also described. The paper contains the results of static and dynamic tests that were performed for five generation units operated in powers for a variety voltage level issues. The test were conducted at conventional coal fueled power plants but also for combined gas-steam power plant. The result of the tests conducted is set of border parameters which allow for uninterrupted operation of tested units. The ways of auxiliary systems modernization and of power transformer enabling the cooperation of the generating unit with the NPS at abnormally low voltages in the power system were proposed.
EN
This paper presents an overview on the effect of grid-connected photovoltaic (PV) system on static and dynamic voltage stability and discusses the analysis techniques used to quantify the effect. A review on the published works showed that the PV system design, PV parameters and the distinct design of power system network affect system voltage stability. Furthermore, a discussion is also made on the optimization techniques used for determining optimum PV placement and sizing for the purpose of improving voltage stability.
PL
W artykule dokonano przeglądu metod analizy wpływu dołączenia systemu fotowoltaicznego na właściwości statyczne i dynamiczne sieci. Odpowiedni projekt wpływa na stabilność napięciową. Analizowano też metody optymalizacji położenia systemu.
EN
This paper presents the low voltage impact on the operation of critical auxiliaries of selected generation units in the national power system. Time limits are determined for the operation of these auxiliaries at low voltage in the power system and the acceptable reduced voltages in their secondary circuits at which the generation unit is capable of interoperation with the system. Upgrades of auxiliary systems are proposed which would enable interoperation of the unit and the system at significantly reduced system voltages.
PL
W artykule przedstawiono wpływ niskich poziomów napięć na funkcjonowanie newralgicznych odbiorników układów potrzeb własnych, wybranych bloków wytwórczych pracujących w KSE. Określono graniczne czasy pracy dla tych odbiorników przy niskich poziomach napięć w KSE oraz dopuszczalne, zaniżone poziomy napięć w obwodach wtórnych układów potrzeb własnych rozpatrywanych bloków wytwórczych, przy których blok wytwórczy jest w stanie współpracować z systemem elektroenergetycznym. Zaproponowano sposoby modernizacji układów potrzeb własnych umożliwiające współpracę bloku wytwórczego z KSE, przy znacznie zaniżonych napięciach w systemie elektroenergetycznym.
PL
Artykuł dotyczy wpływu działania przełącznika zaczepów na wartość napięcia strony wtórnej transformatora oraz zapas stabilności napięciowej węzła odbiorczego. Na wstępie przedstawiono podstawowe informacje dotyczące stabilności napięciowej oraz przełącznika zaczepów. Wartość napięcia strony wtórnej transformatora może być regulowana wykorzystując przełącznik zaczepów. Regulacja ta powoduje również modyfikację parametrów modelu Thevenina widzianego z zacisków wtórnych. Zmiany tych parametrów odzwierciedlają zmiany warunków stabilności napięciowej. Przeprowadzono analizy symulacyjne tego wpływu a wybrane wyniki zaprezentowano w artykule.
EN
The paper concerns influence of transformer tap changer regulation on secondary voltage level and voltage stability margin of receiving node. At the beginning there are presented general information about voltage stability and tap changer. Voltage value of secondary terminals of transformer can be regulated using tap changer. This regulation also affects the calculation of Thevenin equivalent parameters seen from the secondary terminals. Changes of equivalent parameters cause a change of voltage stability conditions. Simulation studies of this influence have been done. Selected results are presented in the paper.
PL
W artykule przedstawiono sposoby modelowania odbioru kompleksowego zawierającego źródła fotowoltaiczne w badaniach stabilności napięciowej systemu elektroenergetycznego. Przegląd sposobów modelowania został uzupełniony o przykładowe badania w zakresie stabilności napięciowej z wykorzystaniem opisanego modelu. W trakcie badań zapas stabilności określany był za pomocą krzywych P-V wyznaczanych w programie symulacyjnym Power Factory. Uzyskane wyniki badań wskazują, że sposób modelowania odbioru kompleksowego zawierającego ogniwa fotowoltaiczne ma istotny wpływ na ocenę stabilności napięciowej systemu elektroenergetycznego.
EN
The paper presents methods of modeling complex load model with photovoltaic sources for analysing the power system voltage stability. The survey was supplemented with examples of analysis of voltage stability using described models of complex load. In the study, the stability margin was determined using P-V curves determined by means of the Power Factory program. The obtained results indicate that the modeling of complex load with photovoltaic cells has a significant impact on the assessment of the power system voltage stability.
PL
W sieci przesyłowej bilans mocy biernej zależy od wartości mocy biernych wytwarzanych w elektrowniach oraz od wartości mocy pojemnościowej generowanej przez linie i statyczne kompensatory. Przy obniżających się napięciach rosną straty przesyłowe mocy biernej i maleją moce ładowania linii. W referacie przedstawiono podstawowe zależności bilansu mocy biernej od wzrostu zapotrzebowania mocy, które następnie wykorzystano do oszacowania punktu pracy sieci przesyłowej, w którym straty przesyłowe mocy biernej przewyższają sumaryczną moc bierną wytwarzaną przez poprzeczne pojemności.
EN
The reactive power balance in the transmission power grid depends on the reactive power produced by the power stations and the value generated by the capacitive power lines and static compensators. Reactive transmission losses become greater than shunt capacitive generation at the turning-point of voltage stability. Then lowering bus voltages drive EPS into voltage collapse point. The paper presents the balance of reactive power depending on the power demand growth, which are then used to estimate the operating point of the transmission network, in which the reactive power transmission losses are greater than the total reactive power generated by the shunt capacity.
PL
W artykule przedstawiono przegląd aktualnie stosowanych modeli odbioru kompleksowego stosowanych do badania stabilności napięciowej systemu elektroenergetycznego. Oprócz opisu modeli, w artykule podano parametry typowych odbiorników wchodzących w skład obioru kompleksowego. Opracowany przegląd został uzupełniony o przykładowe badania w zakresie stabilności napięciowej z wykorzystaniem jednego z opisanych modeli odbioru kompleksowego. W trakcie badań zapas stabilności był określany za pomocą krzywych P-V wyznaczonych za pomocą programu symulacyjnego PowerWorld. Uzyskane wyniki badań wskazują, że sposób modelowania odbioru kompleksowego ma istotny wpływ na ocenę stabilności napięciowej systemu elektroenergetycznego.
EN
The paper presents an overview of the currently used complex load models for analysing the power system voltage stability. In addition to the description of models typical parameters of loads included in the complex load are given. The developed survey was supplemented with examples of analysis of voltage stability using one of the described models of complex load. In the study, the stability margin was determined using PV curves determined by means of the PowerWorld simulation program. The obtained results indicate that the modeling of complex load has a significant impact on the assessment of the power system voltage stability.
PL
Rozwój metod badania stabilności systemu elektroenergetycznego, a w tym stabilności napięciowej, jest realizowany w różnych ośrodkach naukowych na całym świecie. Pomimo że badania na ten temat są realizowane od wielu lat, to wzrost złożoności systemu elektroenergetycznego oraz pojawienie się nowych możliwości badawczych wynikających między innymi z technologii PMU/WAMS sprawiają, że badania w tym zakresie są wciąż aktualne i potrzebne. Zagrożenie utraty stabilności napięciowej dotyczy szczególnie sieci przesyłowych, stąd rozważania zawarte w monografii, choć koncentrują się na tej podsieci, mogą być interesujące dla badaczy zajmujących się układami sieci rozdzielczych czy dystrybucyjnych. W Polsce omawiane problemy dotyczące stabilności napięciowej szczególnie uwypukliły się w pierwszej dekadzie XXI wieku, kiedy to doszło do kilku awarii napięciowych, mających wpływ na funkcjonowanie Krajowego Systemu Elektroenergetycznego. Celem pracy jest poszerzenie wiedzy o zachowaniu się sieci przesyłowej w warunkach deficytu mocy biernej, w aspekcie zagrożenia utratą stabilności napięciowej, oraz próba usystematyzowania na podstawie statycznego modelu SEE ważniejszych metod badania statycznej stabilności napięciowej sieci przesyłowej, a także wyjaśnienie przyczyn jej utraty z opisem awarii systemowych.
EN
Methods for stability analysis of electric power systems, including voltage stability, are being developed in various research centers all over the world. Although the research has already been going on for many years, it needs to be continued further due to the increase in size and complexity of power systems and the emergence of new testing possibilities, for example, the WAMS & PMU technologies. The threat of voltage instability occurring especially concerns electrical power transmission grids, hence the considerations contained in the monograph could be of interest to researchers dealing with a distribution grid. In Poland, these issues were particularly highlighted in the first decade of the 21st century, when a couple of voltage failures affected the functioning of the National Power System. The aim of the study is to increase the knowledge of the behavior of the transmission system in terms of the reactive power deficit and the risk of voltage instability. An attempt is also made to systemize the more important studies of static voltage stability of the transmission grid based on a static state model of an electric power system, as well as to explain the reasons for the loss of stability, with a system blackout description.
EN
The reactive power balance in the transmission power grid depends on the reactive power produced by the power stations and the value generated by the capacitive power lines and static compensators. Reactive transmission losses become greater than shunt capacitive generation at the turning-point of voltage stability. Then lowering bus voltages drive EPS into voltage collapse point. The paper presents the balance of reactive power depending on the power demand growth, which is then used to estimate the operating point of the transmission network, in which the reactive power transmission losses are greater than the total reactive power generated by the shunt capacity.
PL
W sieci przesyłowej bilans mocy biernej zależy od wartości mocy biernych wytwarzanych w elektrowniach oraz od wartości mocy pojemnościowej, generowanej przez linie i statyczne kompensatory. Przy obniżających się napięciach rosną straty przesyłowe mocy biernej i maleją moce ładowania linii. W artykule przedstawiono podstawowe zależności bilansu mocy biernej od wzrostu zapotrzebowania mocy, następnie zależności te wykorzystano do oszacowania punktu pracy sieci przesyłowej, w którym straty przesyłowe mocy biernej przewyższają sumaryczną moc bierną wytwarzaną przez poprzeczne pojemności.
EN
The article summarizes a research project which was conducted in order to ensure what will be the influence of future investments and changes in the Polish Power System on the stability and functionality of the ENERGA SA distribution grid system. Development of the ENERGA SA distribution grid system was also included. Only stable states were tested for various cases of system load and generation in power plants (the Nuclear Power Plant in Żarnowiec was taken into account) and also in wind farms. The system was also tested in N-1 and N-2 states. The result of this study is an overall evaluation of the ENERGA SA distribution grid condition, as well as the identification of potential weak points inside this structure.
PL
Autorzy podsumowują projekt badawczy, zrealizowany jeszcze w trakcie studiów magisterskich, który miał na celu sprawdzenie, jak zmiany w systemie elektroenergetycznym do 2025 roku wpłyną na pracę sieci dystrybucyjnej 110 kV ENERGA SA. W projekcie skupiono się na stanach ustalonych pracy KSE dla różnych wariantów obciążenia systemu i generacji w jednostkach wytwórczych. System poddano analizie prace w stanach normalnych oraz awaryjnych przy przy wyłączeniu elementów KSE, tzw. analiza N-1 i N-2. Wynikiem opracowania była ogólna ocena przystosowania sieci dystrybucyjnej spółki ENERGA SA do pracy przy zmieniającej się strukturze KSE, jak również wskazanie potencjalnych najsłabszych punktów w strukturze zasilania sieci dystrybucyjnej.
EN
Nowadays, the large penetration of wind power generation poses new challenges for the dynamic voltage stability analysis of an electric power system. In this paper is studied the influence of the reactive power management for wind power plants in the dynamic voltage stability of an electric power network under a fault condition, considering two different Doubly-Fed Induction Generators (DFIG) models. The simulation results were obtained using the EUROSTAG software package.
PL
W artykule przedstawiono wpływ zarządzania mocą bierną w elektrowniach wiatrowych na stabilność dynamiczną napięcia w sieci elektrycznej. Zbadano przypadek dwóch różnych modeli generator.
PL
Zapewnienie odpowiednich poziomów napięć i stabilności napięciowej jest obok bilansowania mocy czynnej jednym z najważniejszych zadań operatorów sieci. W artykule opisano zastosowanie algorytmu sterowania bazującego na krzywych nosowych zależności między napięciem i mocą bierną. Analiza sieci podzielona jest na zadania dla równolegle pracujących kontrolerów, zainstalowanych w węzłach sieci. Do realizacji sterowania wykorzystano rozproszony system automatyki Ovation, znany z zastosowań w wielu polskich elektrowniach.
EN
Ensuring proper levels of voltages and voltage stability is, apart from active power balancing, one of the most important tasks belonging to system operators (TSO and DSO). Described is application of control algorithm based on nose curves of dependency between voltage and reactive power. Network analysis is divided into tasks for paralelly working controllers installed in the network nods. To perform the control process, the distributed automation system Ovation is used known from application in many Polish power plants.
PL
Właściwe zarządzanie rozpływem mocy biernej jest dla operatorów sieci przesyłowej i dystrybucyjnej priorytetowym zadaniem ze względu na bezpieczeństwo elektroenergetyczne kraju. W artykule opisano zasadnicze elementy au-tomatycznej metody identyfikacji obszarów systemu elektroenergetycznego, które są podatne na utratę stabilności napięciowej - ze względu na lokalny deficyt mocy biernej. Dla wszystkich możliwych układów pracy systemu opisana technika umożliwia znalezienie słabych węzłów i grupowanie ich w tzw. obszary VCAs (Voltage Control Area) na podstawie istotnych podobieństw w stanach powyłączeniowych. Dodatkowo, metoda identyfikuje generatory, które wpływają na bilans mocy biernej w analizowanym obszarze VCAs. Metoda została z powodzeniem zaimplementowana w tzw. interfejsie VCA, który pomyślnie przeszedł pierwsze testy na sieci będącej w operatywnym kierowaniu przez PSE Operator S.A. zdefiniowanym obszarze tzw. VCAs.
EN
On-line dynamic security assessment has grown in popularity in recent years due to the need to deal with the ever-increasing challenges of secured system operation. In on-line security assessment systems, a snapshot of the actual system condition is captured and analytical engines are used to assess security in near-real-time. This has greatly reduced the uncertainties previously introduced by forecasting required in conventional off-line operational studies. Basic on-line VSA systems are now quite mature, and new features and functions are in development including more comprehensive analyses and artificial intelligence that can be used to assist the operators in maintain secure systems. The paper presents a highly automated method identifying voltage control areas, areas prone to voltage instability, and reactive power reserves requirement ensuring voltage stability under all considered contingencies.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.