The achievement of voltage stability is among the most prominent challenges faced by grid operators. In the past, generator excitation regulation was the only method available, for restoring the voltage to its rated values. However, rapid developments in the areas of power grids and power stations, has led to the need of a new technique, for controlling the voltage level, and maintaining the system in the voltage stability band. Onload tap changing (OLTC) is currently among the most widely employed methods, for improving the stability of the power system voltage. OLTC restores the voltage value, whether the disturbance occurs on its primary or secondary side. While a minor disturbance is easily overcome by OLTC, its capacity for restoring the voltage level, during a significant disturbance, is dependent on its ratings and setting values. The failure of the OLTC transformer, to restore the voltage value within a short period, may result in a collapse of the voltage system, when the transformer proceeds with reverse action. A simulation model in MATLAB Simulink shows the effect of OLTC on the Nineveh power grid.
PL
Osiągnięcie stabilności napięcia jest jednym z najważniejszych wyzwań, przed jakimi stają operatorzy sieci. W przeszłości regulacja wzbudzenia generatora była jedyną dostępną metodą przywracania napięcia do wartości znamionowych. Jednak szybki rozwój w obszarach sieci elektroenergetycznych i elektrowni spowodował konieczność opracowania nowej techniki kontroli poziomu napięcia i utrzymywania systemu w paśmie stabilności napięcia. Zmiana zaczepów pod obciążeniem (OLTC) jest obecnie jedną z najczęściej stosowanych metod poprawy stabilności napięcia systemu elektroenergetycznego. PPZ przywraca wartość napięcia, niezależnie od tego, czy zakłócenie występuje po stronie pierwotnej czy wtórnej. Podczas gdy małe zakłócenie jest łatwo przezwyciężane przez PPZ, jego zdolność do przywracania poziomu napięcia podczas znacznego zakłócenia zależy od jego wartości znamionowych i nastawczych. Awaria transformatora PPZ przywracająca w krótkim czasie wartość napięcia może skutkować załamaniem się układu napięciowego, gdy transformator działa odwrotnie.Model symulacyjny w MATLAB Simulink pokazuje wpływ PPZ na sieć energetyczną Niniwy.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Enhancement of voltage profile of the radial distribution network's (RDN) is seen as a debatable subject because it is one of the factors that influence the system's performance. The power distribution system suffers significant losses as a result of the lower voltage and higher currents. As a result, experts are paying more attention to reduce power losses in the RDN. It is feasible to enhance voltage level of RDN by realizingcombined performance of Distribution Generation (DGs) and capacitor placements. This loss minimization technique tends to lower power flow through lines, which invariably improves system reliability and allows same lines to be used for growing load demand. The practice of optimum positioning and sizing the DGs and capacitors may improve system stability while also minimizes system losses. This article presents a simple and distinct way for determining best point and magnitude of integrated DGs and capacitor units in RDS. The fundamental goal of this project is to restore voltage profile and reduce losses by using Moth Flame Optimization (MFO) algorithm, a well-known and recently created meta-heuristic technique, is used. The algorithm is based on moths' natural behaviour when exposed to light, and it includes two key elements: moths and flames. The proposed methodology has been tested on both IEEE 12 and IEEE 33 node test systems to demonstrate its practicality. The simulated results are compared to ways described in the literature to illustrate the difference between prescribed method and others in terms of enhancing the voltage profile and reducing losses.
PL
Poprawa profilu napięciowego promieniowej sieci dystrybucyjnej (RDN) jest postrzegana jako temat dyskusyjny, ponieważ jest to jeden z czynników wpływających na pracę systemu. System dystrybucji energii ponosi znaczne straty w wyniku niższego napięcia i wyższych prądów. W rezultacie eksperci zwracają większą uwagę na zmniejszenie strat mocy w RDN. Możliwe jest podniesienie poziomu napięcia RDN poprzez realizację połączonej wydajności Generacji Dystrybucyjnej (DG) i rozmieszczenia kondensatorów. Ta technika minimalizacji strat ma tendencję do obniżania przepływu mocy przez linie, co niezmiennie poprawia niezawodność systemu i pozwala na wykorzystanie tych samych linii przy rosnącym zapotrzebowaniu na obciążenie. Praktyka optymalnego pozycjonowania i wymiarowania DG i kondensatorów może poprawić stabilność systemu, jednocześnie minimalizując straty systemu. W tym artykule przedstawiono prosty i wyraźny sposób określania najlepszego punktu i wielkości zintegrowanych DG i jednostek kondensatorów w RDS. Podstawowym celem tego projektu jest przywrócenie profilu napięcia i zmniejszenie strat przy użyciu algorytmu Moth Flame Optimization (MFO), znanej i niedawno stworzonej techniki metaheurystycznej. Algorytm opiera się na naturalnym zachowaniu ciem pod wpływem światła i zawiera dwa kluczowe elementy: ćmy i płomienie. Zaproponowana metodologia została przetestowana w systemach testowych węzłów IEEE 12 i IEEE 33 w celu wykazania jej praktyczności. Symulowane wyniki są porównywane ze sposobami opisanymi w literaturze, aby zilustrować różnicę między zalecaną metodą a innymi pod względem wzmocnienia profilu napięcia i zmniejszenia strat.
The goal of multi-criteria decision making (MCDM) is to select the most appropriate of the alternatives by evaluating many conflicting criteria together. MCDM methods are widely available in the literature and have been used in various energy problems. The key problems studied in electrical power systems in recent years have included voltage instability and voltage collapse. Different flexible alternating current transmission systems (FACTS) equipment has been used for this purpose for decades, increasing voltage stability while enhancing system efficiency, reliability and quality of supply, and offering environmental benefits. Finding the best locations for these devices in terms of voltage stability in actual electrical networks poses a serious problem. Many criteria should be considered when determining the most suitable location for the controller. The aim of this paper is to provide a comparative analysis of MCDM techniques to be used for optimal location of a static VAR compensator (SVC) device in terms of voltage stability. The ideal location can be determined by means of sorting according to priority criteria. The proposed approach was carried out using the Power System Analysis Toolbox (PSAT) in MATLAB in the IEEE 14-bus test system. Using ten different MCDM methods, the most appropriate locations were compared among themselves and a single ranking list was obtained, integrated with the Borda count method, which is a data fusion technique. The application results showed that the methods used are consistent among themselves. It was revealed that the integrated model was an appropriate method that could be used for optimal location selection, providing reliable and satisfactory results to power system planners.
4
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Artykuł dotyczy zagadnienia stabilności napięcia sieci elektrycznej dla przebiegów niesinusoidalnych, okresowych. Przedstawiono uniwersalne rozwiązanie tego problemu w dziedzinie czasu i częstotliwości przy użyciu rachunku operatorowego, z uwzględnieniem strat energii wewnątrz źródła. Ponieważ matematycznie zadanie to jest dość złożone, aby je uprościć, skorzystano z zasady podobieństwa. Operator zastępczy admitancji wewnętrznej źródła jest zastąpiony przez rzeczywisty współczynnik, mający status kondunktancji.
EN
The article concerns the issue of voltage power supply stability for non-sinusoidal periodic waveforms. One solution to this problem, in the time and frequency domain using operational calculus and taking into account energy losses within the source, was presented. Since the mathematical task is quite complex, to be simplified made use of the principle of similarity. A substitute operator of source internal admittance is replaced by a real factor, having the status of conductance.
5
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
A voltage collapse event is complex and localized in nature, but its effect is extensive. A vital effect of voltage collapse is total system collapse or blackouts, which will result in a significant loss to utility companies. Online monitoring of power system stability has thus become an important factor for electric power utilities. The final resort prevent the occurrence of a voltage collapse incident is the implementation of an undervoltage load shedding (UVLS) scheme. This paper focuses on the introduction of the UVLS scheme and presents an overview of the principles of the UVLS that are crucial to the design of such a protection scheme. This paper also presents the existing industrial practices and other research methods available to date.
PL
W artykule opisano algorytm UVLS (Under Voltage Shedding Schemes) zastosowany do monitorowania stabilności systemu energetycznego I zapobiegania jego zapaściom. Artykuł jest przeglądem metod stosowanych w praktyce oraz prac badawczych w tej dziedzinie.
6
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
This paper forms part of an ongoing system development of the Ghanaian power network. Preliminary studies have shown that the northern sector is venerable to voltage instability which has led to the proposed installation of STATCOM at Tamale. It is therefore necessary to assess the performance of the device when put in operation. Comparison had therefore been made between the use of STATCOM and Fixed Compensator. Line and generator contingencies as well as small signal disturbances analysis had been carried out. Voltage stability is improved with the installation of STATCOM as well as reduction in voltage oscillation during transient. Loadability limit of the system is also increased. Further evaluation targeted at the inter-tie with Burkina Faso has been proposed.
PL
W artykule opisano prace nad rozwojem sieci elektroenergetycznej Ghany. Badania wstępne wykazały, że północny sektor sieci jest wpływa na niestabilność napięcia. Jako rozwiązanie zaproponowano instalacje kompensatora STATCOM. Dokonano jego porównania z klasycznymi filtrami biernymi, zarówno pod kątem potencjalnych awarii w sieci, jak i niewielkich zakłóceń. Proponowane rozwiązanie zwiększa stabilność napięcia oraz możliwości obciążeniowe.
7
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
With the advent of restructuring in power system and the exponential growth in the load demand, the importance of Distribution Generation (DG) has been increased. The DG is used to reduce the power losses and also to improve the system stability. The non-optimum DG placement and sizing could result in increase power losses and instability of the power system. This paper presents the comparative study for DG allocation techniques based on three different indicators namely Active power VSI (P-VSI), Reactive power VSI (Q-VSI) and Power Losses Reduction (PLR) indicator. The performances of these indicators are also compared for optimal DG output, maximum loss reduction, improvement in voltage profile and improvement in voltage stability. Standard 12-bus and 33-bus radial distribution networks are used as a test system. From the analysis and results, it is found that PLR performance is better than P-VSI and Q-VSI indicators in DG allocation.
PL
W artykule przedstawiono analizę porównawczą technik alokacji kogeneracji rozproszonej, opartych na trzech wskaźnikach: mocy czynnej falownika, mocy biernej falownika oraz redukcji strat mocy. W warunkach optymalnej pracy dokonano porównania maksymalnej możliwej redukcji strat, jakości profilu napięcia oraz stabilności napięcia wybranych metod. W testach systemów uwzględniono standardową 12 i 33-liniową sieć dystrybucji energii. Przedstawiono wnioski końcowe analizy.
8
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
In heavily loaded systems, voltage stability limit is usually dominant and voltage instability is usually observed following large disturbance. This is typically the case in the deregulated environment as the transmission systems are operating under more stressed condition due to increased transaction level associated with open access. In this paper simple voltage stability analysis is carried out for a multibus power system (26 Bus System).The effect of shunt compensation on critical eigen value of Jacobian matrix, system loadabilty and static voltage stability is established.
PL
W systemie przeciążonym jednym z najważniejszych parametrów jest stabilność napięcia. W artykule przeprowadzono analizę stabilności napięcia w wieloszynowym systemie (26 szyn).
9
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule podano nieznany dotąd związek miedzy mocą bierną a stabilnością napięcia zasilania w przypadku występowania okresowych niesinusoidalnych sygnałów napięcia i prądu.
EN
In the article the unknown up to now relationship between the reactive power and stability of voltage of source were given. The nonsinusoidal situation is considered.