Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 243

Liczba wyników na stronie
first rewind previous Strona / 13 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  sprawność
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 13 next fast forward last
EN
Traditional industrial robots come with prime movers, i.e. electric motors (EMs), which range from a few hundred to just a few kilo watts of power ratings. However, for autonomous robotic navigation systems, we require motors which are lightweight with the aspect of high torque and power density. This aspect is very critical when the EMs in robotic navigations are subjected to harsh high temperature survival conditions, where the sustainability of the performance metrics of the electromagnetic system of the EMs degrades with the prevailing high temperature conditions. Hence, this research work addresses and formulates the design methodology to develop a 630 W high temperature PMSM (HTPMSM) in the aspect of high torque and power density, which can be used for the autonomous robotic navigation systems under high temperature survival conditions of 200°C. Two types of rotor configurations i.e. the surface permanent magnet type (SPM) and the interior permanent magnet type (IPM) of HTPMSM are examined for its optimal electromagnetic metrics under the temperature conditions of 200◦C. The 630 W HTPMSM is designed to deliver the rated torque of 2 Nm within the volumetric & diametric constraints of DxL, which comes at 80 × 70 mm at the rated speed of 3 000 rpm with the survival temperature of 200°C and target efficiency greater than 90%. The FEM based results are validated through the hardware prototypes for both SPM and IPM types, and the results confirm the effectiveness of the proposed design methodology of HTPMSM for sustainable autonomous robotic navigation applications.
EN
Congestion is a significant problem affecting the operational processes of a hospital’s outpatient department (OPD). Congestion especially affects the OPD’s architectural space, due to the increased number of patients. Recently, digital tools have been used in healthcare systems to reduce congestion and help the OPD improve its operational processes; one of these tools is the virtual examination room. However, patients still need to be examined by physicians in the OPD, and digital tools alone cannot solve all the problems that congestion creates. The authors of this paper conducted a study that offers a new way to alleviate congestion in the OPD by combining physical and digital solutions to increase OPD efficiency and optimize its operational processes. The study created an alternative operational plan that adds virtual examination rooms to reduce congestion. This plan allows the OPD to increase the number of physical and virtual examination rooms by almost 110% and increase the number physically and virtually examined patients by 153% each day. The plan also redesigns some architectural spaces at the OPD to enhance the environment and match the hospital’s requirement for authorized bodies.
PL
Przestoje są poważnym problemem, który dotyczy procesów operacyjnych poliklinik szpitalnych (PS). Dotyczy on zwłaszcza przestrzeni architektonicznych PS, z uwagi na zwiększoną ilość pacjentów. W ostatnim czasie użyto narzędzi cyfrowych w systemach opieki zdrowotnej, aby zmniejszyć przestoje i ułatwić polepszanie procesów operacyjnych w PS; jednym z takich narzędzi jest wirtualny pokój badań. Niemniej jednak pacjenci wciąż muszą być przebadani przez lekarzy w PS i narzędzia cyfrowe same w sobie nie rozwiążą wszystkich problemów, które powodują przestoje. Autorzy niniejszego artykułu przeprowadzili badanie, które oferuje nowy sposób złagodzenia przestojów w PS poprzez połączenie fizycznych i cyfrowych rozwiązań, które zwiększają sprawność PS i optymalizują procesy operacyjne. Zaproponowano alternatywny plan operacyjny, który dodaje wirtualne pokoje badań celem zmniejszenia przestojów. Plan ten pozwala PS na zwiększenie ilości fizycznych i wirtualnych pokojów badań o niemal 110% oraz na zwiększenie dziennej ilości przebadanych fizycznie i wirtualnie pacjentów o 153%. Plan przewiduje przeprojektowanie wnętrz architektonicznych PS, aby polepszyć środowisko i dostosować szpital do wymogów autoryzowanych instytucji.
PL
Zgodnie z obowiązującymi przepisami budowlanymi [i] konieczne jest stosowanie przegród budowlanych o wysokiej izolacyjności cieplnej (spełnienie wymagania Umax ) oraz jednoczesne zapewnienie niskich wartości wskaźnika zapotrzebowania na nieodnawialną energię pierwotną (spełnienie wymagania EPmax ). Osiągnięcie odpowiednio niskiego wskaźnika EP zależy od wielu zmiennych, związanych zarówno z rozwiązaniami architektoniczno-budowlanymi, jak i systemami technicznego wyposażenia budynku, w szczególności ogrzewania, chłodzenia, wentylacji i przygotowania cieplej wody użytkowej. Możliwe są różne kombinacje ich wzajemnej konfiguracji. W artykule zaprezentowano metodę ustalania zestawu rozwiązań architektoniczno-instalacyjnych pozwalających spełnić kryterium EPmax dla budynków mieszkalnych wielorodzinnych z wentylacją naturalną lub hybrydową. Pozwala ona w prosty sposób określić, jakie systemy technicznego wyposażenia budynku należy zastosować, by dla danego rozwiązania architektonicznego uzyskać wymaganą wartość wskaźnika EP, lub jak zmodyfikować rozwiązanie architektoniczne przy zastosowaniu danego systemu HVAC i c.w.u. Metoda ta jest uniwersalna - można ją zastosować do przeprowadzenia podobnej analizy przy wykorzystaniu innej metodologii obliczeń charakterystyki energetycznej budynku.
EN
According to the current building regulations [1] it is necessary to use building envelope with good thermal insulation (meeting the Umax requirement) and at the same time ensuring low values of non-renewable primary energy consumption (meeting the PEmax requirement). Achieving a sufficiently low PE indicator depends on many variables, related to both architectural solutions and building technical systems, in particular heating, cooling, ventilation and domestic hot water. Various configurations of architectural and HVAC design parameters are possible. The article presents a method for determining a set of solutions which meet the PEmax criterion for multifamily buildings with natural ventilation or hybrid ventilation. Presented approach allows to easily determine which systems should be used to achieve the required value of the PE index for a given architectural solution, or how to modify the architectural solution with the use of a given HVAC and DHW system. This method is universal - it can be used to carry out a similar analysis using a different methodology for calculating the energy performance of the building.
4
Content available remote Methods for increasing electromagnetic efficiency in induction levitator
EN
Electric devices with a levitation element (LE) are widely used in the automation of production processes due to their simple design, high accuracy and reliability. When used as an electrical control device for automation, it is necessary to increase its electromagnetic efficiency and quality factor to increase the stability of the characteristics of the induction levitator (IL). To do this, the article determines and analyzes the quality factor of the working air gap by determining the main dimensions of induction levitation, and also discusses ways to increase the electromagnetic efficiency
PL
Urządzenia elektryczne z elementem lewitującym (LE) mają szerokie zastosowanie w automatyzacji procesów produkcyjnych ze względu na swoją prostą konstrukcję, dużą dokładność i niezawodność. W przypadku zastosowania jako elektryczne urządzenie sterujące do automatyki konieczne jest zwiększenie jego sprawności elektromagnetycznej i współczynnika jakości w celu zwiększenia stabilności charakterystyk lewitatora indukcyjnego (IL). W tym celu w artykule wyznaczono i przeanalizowano współczynnik jakości roboczej szczeliny powietrznej poprzez wyznaczenie głównych wymiarów lewitacji indukcyjnej, a także omówiono sposoby zwiększenia sprawności elektromagnetycznej.
5
Content available remote Analysis of synchronized asynchronous generator for a wind electric installation
EN
Objective. Analysis of the effectiveness of the use of SAG, excited according to a fundamentally new scheme, in a wind electric installation. This article analysis the application of the efficiency of a synchronized asynchronous generator in a wind electric installation. This is natural in vibration damping, which causes gusts of wind and changes in wind speed, as well as an increase in the efficiency of the device at low wind speeds. The article shows a schematic diagram of a synchronized asynchronous generator of a wind electric installation. Some properties of the synchronized asynchronous generator that drives the circuit are also explored. The article presents the advantages of using a synchronized asynchronous generator for wind turbines. The results of calculated characteristics for the given system of values are given. The possibility of operation at cosφ =1 is considered.
PL
Cel. Analiza efektywności wykorzystania SAG, wzbudzonego według zasadniczo nowego schematu, w wiatrowej instalacji elektrycznej. W artykule dokonano analizy zastosowania sprawności zsynchronizowanego generatora asynchronicznego w elektrowni wiatrowej. Jest to naturalne przy tłumieniu drgań, które powoduje podmuchy wiatru i zmiany prędkości wiatru oraz wzrost wydajności urządzenia przy małych prędkościach wiatru. W artykule przedstawiono schemat ideowy zsynchronizowanego generatora asynchronicznego wiatrowej instalacji elektrycznej. Badane są również niektóre właściwości zsynchronizowanego generatora asynchronicznego, który napędza obwód. W artykule przedstawiono zalety zastosowania zsynchronizowanego generatora asynchronicznego do turbin wiatrowych. Podano wyniki obliczonych charakterystyk dla zadanego systemu wartości. Rozważana jest możliwość pracy przy cosφ =1.
6
Content available remote Analysing the performance of H5 inverters in a photovoltaic system
EN
In this paper, a simulation study on H5 topology is presented. H5 topology is a commonly used inverter in photovoltaic (PV) systems because it is cost-effective, simple, and highly efficient. The study compares the performance of H4 topology, H5 topology, and an improved version of H5 topology in terms of leakage current. The power device was subjected to Unipolar Sinusoidal Pulse Width Modulation (SPWM) technique to determine the overall operation within a switching frequency range of 2 kHz to 20 kHz. The input system utilized a PV Matlab/Simulink model that specified a maximum power of 213.15 Watt and Open Circuit Voltage (Voc) of 36.3 V. The improved H5 topology demonstrated a significant reduction in leakage current, measuring 0.015 A compared to the conventional H5 topology's 0.02 A.
XX
W artykule przedstawiono badanie symulacyjne topologii H5. Topologia H5 jest powszechnie stosowanym falownikiem w systemach fotowoltaicznych (PV), ponieważ jest opłacalna, prosta i wysoce wydajna. Badanie porównuje wydajność topologii H4, topologii H5 i ulepszonej wersji topologii H5 pod względem prądu upływu. Urządzenie zasilające zostało poddane technice jednobiegunowej sinusoidalnej modulacji szerokości impulsu (SPWM) w celu określenia ogólnej pracy w zakresie częstotliwości przełączania od 2 kHz do 20 kHz. System wejściowy wykorzystywał model PV Matlab/Simulink, który określał maksymalną moc 213,15 W i napięcie obwodu otwartego (Voc) 36,3 V. Ulepszona topologia H5 wykazała znaczne zmniejszenie prądu upływu, mierząc 0,015 A w porównaniu z konwencjonalną topologią H5 0,02A.
7
Content available remote Wpływ warunków atmosferycznych na pracę modułów fotowoltaicznych
PL
W pracy przedstawiono przegląd głównych czynników atmosferycznych tj. natężenia promieniowania słonecznego, temperatury otoczenia, wiatru, opadów atmosferycznych i zanieczyszczeń oraz ich wpływ na efektywność pracy modułów fotowoltaicznych wykonanych w różnych technologiach. Zaprezentowano wybrane modele służące do określania temperatury ogniwa będącej funkcją temperatury otoczenia, natężenia promieniowania i prędkości wiatru. Na podstawie kilku modeli określono wpływ danego czynnika atmosferycznego na temperaturę ogniwa. Zaobserwowano, że zmiana temperatury otoczenia wpływa na temperaturę ogniwa w sposób liniowy, i oceniono, że zwiększenie temperatury otoczenia o 1ºC wpływa na podwyższenie temperatury ogniwa również o około 1ºC. Natężenie promieniowania słonecznego również ma liniowy wpływ na zmianę temperatury ogniwa, a jego wzrost o 100 W/m2 powoduje zwiększenie temperatury ogniwa w przedziale 1,75-3,1ºC w zależności od obranego modelu. Wpływ wiatru na temperaturę ogniw nie jest liniowy i dodatkowo jest czynnikiem atmosferycznym, który powoduje pozytywny wpływ na temperaturę ogniwa, a wraz ze zwiększeniem jego prędkości o 1 m/s średni spadek temperatury ogniwa wynosił od 0,6 do 2ºC w zależności od analizowanego modelu, przy czym zazwyczaj większy spadek obserwowano przy mniejszych prędkościach wiatru. Określono również wpływ zmiany temperatury modułu na zmianę sprawności konwersji energii promieniowania słonecznego dla wybranych komercyjnie dostępnych modułów fotowoltaicznych. Zaobserwowano, że sprawność zmienia się liniowo wraz z temperaturą, a średni spadek sprawności w zależności od modelu wynosił od 0,68 do 0,73 pp. na każde 10ºC wzrostu temperatury modułu, dla natężenia promieniowania słonecznego wynoszącego 1000 W/m2.
EN
This paper presents an analysis of the main weather conditions, meaning solar irradiance, ambient temperature, wind, rainfall, snow layer occurrence and pollution as well as their influence on efficiency of different kinds of solar modules. Mathematical models used to determine a solar cell temperature depending on the ambient temperature, solar irradiance and the speed of wind are presented. The impact of every factor on the photovoltaic cell temperature was established based on a few models. The results were as follows: ambient temperature affects cell temperature linearly, an increase of 1°C results in solar cell temperature’s rise of approximately 1°C. The linear dependency is also observed in influence of solar irradiance, a 100 W/m2 increase causes a 1,75-3,1°C rise of a photovoltaic cell temperature, depending on the chosen model. The wind impact however is not linear and it is a weather factor causing a positive outcome for a solar cell temperature - by increasing wind speed by 1 m/s, the average decrease of the temperature of a solar cell was defined in a range from 0,6 to 2 degrees Celsius, depending on the model used to determine it and more significant decrease of temperature was observed with lower values of wind velocity. The impact of temperature change of a PV module on change in solar energy conversion’s efficiency was determined for a chosen solar module available on the market. A linear dependency between efficiency and temperature was observed. An average decrease of efficiency depending on the photovoltaic panel ranged from 0,68 to 0,73 percentage point for every 10°C increase of module’s temperature in case of solar irradiance of 1000 W/m2.
8
Content available remote Study and analysis of a novel compact cubic antenna design for WSN applications
EN
This paper presents a novel miniaturized 3-D cubic antenna to be used for wireless sensor network (WSN) applications. The geometry of this antenna is designed as a cube including a meander dipole antenna. A truly omnidirectional pattern is produced by this antenna in both E-plane and H-plane, which allows for non-intermittent communication that is orientation independent. The operating frequency lies in the ISM band (centred in 2.45 GHz). The cubic shape of the antenna allows for smart packaging, as sensor equipment may be easily integrated into the hallow cube interior. All results of the simulations were performed by CST Microwave Studio simulation software and validated with HFSS.
PL
W artykule przedstawiono nowatorską, miniaturową antenę sześcienną 3D do zastosowania w bezprzewodowej sieci czujników (WSN). Geometria tej anteny jest zaprojektowana jako sześcian zawierający meandrową antenę dipolową. Ta antena wytwarza prawdziwie dookólny wzór zarówno w płaszczyźnie E, jak i H, co pozwala na nieprzerwaną komunikację, która jest niezależna od orientacji. Częstotliwość pracy leży w paśmie ISM (scentrowanym w 2,45 GHz). Sześcienny kształt anteny pozwala na sprytne pakowanie, ponieważ wyposażenie czujnika można łatwo zintegrować z wnętrzem sześcianu. Wszystkie wyniki symulacji zostały przeprowadzone przez oprogramowanie symulacyjne CST Microwave Studio i zweryfikowane za pomocą HFSS.
EN
The carried out analysis concerns 2 kWp building integrated photovoltaic installation (BIPV) at the Chemistry Faculty of Gdansk University of Technology. It was proven that the generated energy data for every month diverge significantly from the expected vales. It is corelated with suboptimal orientation of the installation itself, as well as with the tilt angle varying from optimal.
PL
Przeprowadzona analiza dotyczyła uzysków energetycznych 2 kWp instalacji fotowoltaicznej zintegrowanej z budynkiem (BIPV) Wydziału Chemicznego Politechniki Gdańskiej. Wykazano, iż dla każdego miesiąca otrzymane wartości generowanej energii wyraźnie odbiegają od spodziewanych. Jest to skorelowane z nieoptymalną orientacją samej instalacji, jak również kątem nachylenia obiegającym od optymalnego.
10
Content available remote Analysis and comparison of energy indices of dc-dc pulse converters
EN
The computer simulation was used in order to analyze and compare circuit configurations of pulse-width converters and pulse-frequency converters. The principle of operation and main differences were described. The circuits of pulse-width converter and pulse-frequency converter were modelled in the Matlab software using blocks from the following library: Simulink / SimPowerSystem / Simscape. The block, which performs calculation of static and dynamic power losses of insulated gate bipolar transistor (IGBT), was created. The performance curves of the IGBT were approximated in order to calculate losses. The obtained curves quite accurately describe those of the IGBT in use (CM800HC-66H by MITSUBISHI). It was shown that dynamic losses can be reduced and conversion efficiency can be increased when using the pulse-frequency converters in comparison with pulse-width converters. It was noted that for values of duty cycle in the range from 0.1 to 0.5 the efficiency of pulse-frequency converter is significantly higher than that of pulse-width converter.
PL
Symulacja komputerowa została wykorzystana do analizy i porównania konfiguracji obwodów przetworników o szerokości impulsu i częstotliwości impulsu. Opisano zasadę działania i główne różnice. Obwody przetwornika szerokości impulsu i przetwornika częstotliwości impulsu zamodelowano w programie Matlab z wykorzystaniem bloków z biblioteki: Simulink / SimPowerSystem / Simscape. Stworzono blok, który wykonuje obliczenia statycznych i dynamicznych strat mocy tranzystora bipolarnego z izolowaną bramką (IGBT). Krzywe wydajności IGBT zostały przybliżone w celu obliczenia strat. Otrzymane krzywe dość dokładnie opisują krzywe zastosowanego tranzystora IGBT (CM800HC-66H firmy MITSUBISHI). Wykazano, że przy zastosowaniu przekształtników impulsowo-częstotliwościowych można zmniejszyć straty dynamiczne i zwiększyć sprawność konwersji w porównaniu z przekształtnikami o szerokości impulsu. Stwierdzono, że dla wartości współczynnika wypełnienia w zakresie od 0,1 do 0,5 sprawność przetwornika częstotliwości impulsów jest znacznie wyższa niż przetwornika szerokości impulsu.
11
Content available Energooszczędny układ napędowy
PL
Moment znamionowy maszyny elektrycznej determinuje jej gabaryt. Maszyny wolnoobrotowe mają większą objętość i masę od maszyn o tej samej mocy znamionowej, lecz wyższej znamionowej prędkości obrotowej. Sprawność energetyczna maszyny obciążonej mocą znacznie mniejszą od mocy znamionowej ma także sprawność mniejszą od znamionowej. Porównano sprawność energetyczną trzech układów napędowych napędzających maszynę roboczą z prędkością obrotową n = 187,5 obr./min. Wykazano, że sprawność silnika synchronicznego o liczbie par biegunów p = 16 w warunkach pracy wynosi η = 77% i jest mniejsza o 16% od sprawności silnika synchronicznego i silnika indukcyjnego o liczbie par biegunów p = 2 plus przekładnie mechaniczne o przełożeniu i = 8. Silniki synchroniczny i indukcyjny, o liczbie par biegunów p = 2 plus przekładnie mechaniczne o przełożeniu i = 8 stanowią napęd alternatywny do silnika synchronicznego wolnoobrotowego o liczbie par biegunów p = 16.
EN
The rated torque of the electric machine determines its dimensions. Slow-running machines have a larger volume and weight than machines with the same rated power but higher rated rotational speed. The energy efficiency of the machine loaded with power significantly lower than the rated power also has the efficiency lower than the rated one. The energy efficiency of three drive systems driving a working machine with a rotational speed of n = 187,5 rpm was compared and it was shown that the efficiency of a synchronous motor with the number of p = 16 poles under operating conditions is η = 77% and is 16% lower than that of a synchronous motor and an induction motor with the number of pole pairs p = 2, plus mechanical gears with the ratio i = 8. Synchronous and induction motors with the number of pole pairs p = 2 plus mechanical gears with the ratio i = 8 constitute an alternative drive to the slow-speed synchronous motor with the number of pole pairs p = 16
EN
Monitoring the accuracy of meters by qualified workers and managers is a preventive measure of every organization. The paper focuses on monitoring the accuracy of measuring devices and proposes preventive and corrective actions. The discussed measurement device was tested for accuracy using accuracy indexes Cg and Cgk. The identified deviations in measurements showed that the meter was not fully efficient. Consequently, actions were taken to ensuring that the measurement device is accurate.
PL
Monitorowanie sprawności mierników to działanie prewencyjne każdej organizacji. Pracownicy działów jakości oraz osoby odpowiedzialne za kontrolę i pomiary wyrobów końcowych są zobowiązani do ciągłej kontroli sprzętu pomiarowego. W artykule skupiono się na monitorowaniu dokładności przyrządu pomiarowego oraz zaproponowaniu działań zapobiegawczych i korygujących. Dokładność przyrządu pomiarowego określono za pomocą wskaźników dokładności Cg i Cgk. Stwierdzono, że odchylenia w pomiarach świadczą o tym, że miernik nie jest w pełni sprawny. W związku z tym podjęto działania naprawcze, które zapewniły sprawność przyrządu pomiarowego.
13
Content available remote Obliczanie mocy w układach hydrauliki siłowej
PL
Jak wiadomo, energia w przyrodzie nie znika, tylko zmienia swoją postać. Definicja pracy mówi, że jest ona miarą energii przekazanej pomiędzy układami fizycznymi. W układach hydrauliki siłowej wykonywana jest praca mechaniczna, co oznacza, że generowane siły powodują przemieszczenie - przesunięcie łub obrót - obiektów zewnętrznych, na które oddziałują, np. podniesienie ładunku lub obrót bębna. Z kolei moc to praca wykonana w jednostce czasu, czyli moc jest szybkością zmiany jednej postaci energii na drugą. Jakie rodzaje mocy występują w typowym układzie hydrauliki siłowej? Jak obliczać moc dostarczaną do układu? Co to jest sprawność? Odpowiedzi na te pytania znajdują się w przedstawionym artykule.
14
Content available Straty mocy i sprawność transformatorów
PL
W artykule zdefiniowano sprawność energetyczną transformatorów. Stały postęp technologii blachy transformatorowej owocuje obniżeniem stratności i wzrostem indukcji nasycenia rdzenia. Stwarza to warunki do zmniejszenia masy rdzenia i w mniejszym stopniu zmniejszenia masy uzwojenia. Podano przykłady strat mocy jałowych i obciążeniowych transformatorów rozdzielczych produkowanych w latach 60. XX w. i produkowanych obecnie. Od 01 lipca 2021 r. Komisja Unii Europejskiej [8] i Normy Europejskie [6,7] ustaliły dalsze obniżenie strat mocy i zwiększenie sprawności w instalowanych transformatorach.
EN
The article defines the energy efficiency of transformers. The constant advancement in transformer sheet technology results in a reduction in loss and an increase in core saturation flux density. This creates conditions for reducing the core mass and, to a lesser extent, for reducing the winding mass. Examples of noload and load losses of distribution transformers manufactured in the 1960s and currently manufactured are given. From 01 July 2021, the European Union Commission [8] and European Standards [6,7] have established a further reduction of power losses and an increase in efficiency in installed transformers.
15
Content available Energooszczędny układ napędowy
PL
Moment znamionowy maszyny elektrycznej determinuje jej gabaryt. Maszyny wolnoobrotowe mają większą objętość i masę od maszyn o tej samej mocy znamionowej lecz wyższej znamionowej prędkości obrotowej. Sprawność energetyczna maszyny obciążonej mocą znacznie mniejszą od mocy znamionowej ma także sprawności mniejszą od znamionowej. Porównano sprawność energetyczną trzech układów napędowych napędzających maszynę roboczą z prędkością obrotową n = 187,5 obr/min i wykazano, że sprawność silnika synchronicznego o liczbie par biegunów p = 16, w warunkach pracy, wynosi η = 77% i jest mniejsza o 16% od sprawności silnika synchronicznego i silnika indukcyjnego, o liczbie par biegunów p = 2, plus przekładnie mechaniczne o przełożeniu i = 8. Silniki synchroniczny i indukcyjny, o liczbie par biegunów p = 2, plus przekładnie mechaniczne o przełożeniu i = 8 stanowią napęd alternatywny do silnika synchronicznego wolnoobrotowego o liczbie par biegunów p = 16.
EN
The rated torque of the electric machine determines its dimensions. Slow-running machines have a larger volume and weight than machines with the same rated power but higher rated rotational speed. The energy efficiency of the machine loaded with power significantly lower than the rated power also has the efficiency lower than the rated one. The energy efficiency of three drive systems driving a working machine with a rotational speed of n = 187.5 rpm was compared and it was shown that the efficiency of a synchronous motor with the number of p = 16 poles under operating conditions is η = 77% and is 16% lower than that of a synchronous motor and an induction motor with the number of pole pairs p = 2, plus mechanical gears with the ratio i = 8. Synchronous and induction motors with the number of pole pairs plus p = 2 mechanical gears with the ratio i = 8 constitute an alternative drive to the slow-speed synchronous motor with the number of pole pairs p = 16.
PL
W ostatnich latach wiele się mówi o konieczności poprawy efektywności energetycznej, m.in. transportu cieczy. Jako odrębny temat podnosi się potrzebę powiększenia niezawodności poszczególnych urządzeń, jak również całych obiektów, np. pompowni wodociągowych, kanalizacyjnych i ciepłowniczych. Rzadko jednak łączy się te dwa zagadnienia i wpływ niezawodności na efektywność energetyczną. Związek pomiędzy sprawnością urządzenia, instalacji, układu lub procesu a efektywnością energetyczną nie jest oczywisty.
EN
This article establishes the efficiency of a single-circuit thermosyphon domestic solar hot water system for Polish cities such as Warsaw, Lublin, Bialystok, Czestochowa and Szczecin, using two indicators, namely the solar fraction and the efficiency of solar collector. It was found that of the selected cities, Bialystok is the most attractive in terms of using solar energy for hot water supply systems, as the solar hot water supply system has the highest solar fraction f = 0.64, and the efficiency of the solar collector is ƞ = 0.553. The lowest efficiency of the solar hot water supply system is observed for the city of Szczecin, which is characterized by indicators f = 0.49 and ƞ = 0.505, respectively. These analytical studies show that the use of the solar hot water system in selected cities in Poland can save on traditional energy sources for hot water systems by up to 50%.
18
Content available remote Straty mocy i sprawność transformatorów
PL
W artykule zdefiniowano sprawność energetyczną transformatorów. Stały postęp w technologii produkcji blachy transformatorowej owocuje obniżeniem stratności i wzrostem indukcji nasycenia rdzenia. Stwarza to warunki do zmniejszenia masy rdzenia i, w mniejszym stopniu, zmniejszenia masy uzwojenia. Podano przykłady strat mocy w stanie jałowym i obciążeniu transformatorów rozdzielczych produkowanych w latach 60. XX w. i obecnie. Komisja Unii Europejskiej [8] i Normy Europejskie [6,7] ustaliły od 1 lipca 2021 r., dalsze obniżenie strat mocy i zwiększenie sprawności instalowanych transformatorów.
EN
Energy efficiency of transformers has been defined in the paper. The continuous progress noted in technology of electrical steel used for transformer laminations results in decreased lossiness and increase of flux density saturation in the core. Therefore, conditions are established for decreasing core weight and, to a lesser degree, decreasing winding weight as well. The examples of idle and load power losses have been provided for distribution transformers manufactured in 1960s and for those manufactured now. The European Commission [8] and European Standards have ruled that further decrease in power losses and increase in efficiency of newly-installed transformers must come into effect by 1st July, 2021.
PL
Znając problem nisko-sprawnościowej pracy wentylatorów promieniowych w zabudowach kanałowych, autorzy podjęli się numerycznej analizy wpływu zmiany średnicy zabudowy oraz geometrycznego kąta na wlocie na pracę tych urządzeń. Obliczenia przeprowadzono w oparciu o równania RANS domknięte modelem turbulencji k-ω SST w ramach solvera Ansys CFX. Porównano osiągi różnych wariantów średnicy zabudowy i kątów, a także zidentyfikowano kluczowe zjawiska przepływowe, mające bezpośredni wpływ na sprawność tego typu wentylatora. Największy uzyskany wzrost sprawności wyniósł 15 punktów procentowych.
first rewind previous Strona / 13 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.