Ograniczanie wyników
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 25

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  spektroskopia dielektryczna
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
EN
Transformers are crucial elements in the transmission and distribution of electrical energy. The importance of diagnosing these equipments are two-fold: (1) the necessity of service reliability and (2) the likelihood to avoid economic and environmental concerns. Under service conditions, the electrical and thermal stresses or chemical contaminants may degrade the insulation oil inside the transformer and cause incipient failures or reduce its service life. Partial discharges well recognized to be among the most common stresses that can lead to slow but steady degradation of insulating oil in transformers. The present work aims at understanding the influence of low energy electrical discharge on mineral oil based on two spectroscopic methods: FTIR spectroscopy and Frequency Domain Spectroscopy (FDS). An electrical fault has been created by continuous discharge of 10 kV on the surface of various oil samples according to the ASTM D6180. From the FDS results, it was found that the amount of charge carriers and moisture increased with the aging time elapsed that influences the conduction phenomena and in turn, increases the dissipation factor. These results are confirmed by the FTIR results, which show that the intensity of the peak absorbance of the C–H and C-C functional group decreased with aging. The application of these two methods may help monitoring the condition of oil. A combined FTIR and FDS measurements highlighted the correlations between modifications in electrical properties and changes in the chemical structure of the oil under electrical accelerated ageing.
PL
W artykule przedstawiono wyniki badań eksperymentalnych zespolonej przenikalności elektrycznej w dziedzinie wysokiej częstotliwości, przeprowadzone na próbkach izolacji impregnowanej. Warstwę izolacji stałej wykonano z dwóch rodzajów papierów elektrotechnicznych: w pełni aramidowego typu NOMEX® T410 oraz z celulozowo-aramidowego typu NOMEX® T910. Jako impregnat wykorzystano trzy rodzaje cieczy dielektrycznej: olej mineralny Nynas Nytro 10X, ester syntetyczny Midel 7131 oraz ester naturalny Midel en1204. Celem badań była obserwacja oraz analiza zmian właściwości dielektrycznych tych materiałów. W badaniach uwzględniono wpływ oddziaływania temperatury w zakresie od 20°C do 100°C, co odpowiada typowym warunkom eksploatacji izolacji impregnowanej w transformatorach mocy.
EN
The article presents the results of experimental research on complex electric permittivity in the high frequency domain, carried out on impregnated insulation samples. The solid insulation layer was made of two types of electrotechnical papers: NOMEX® T410 fully aramid type and NOMEX® T910 cellulose-aramid type. As impregnation, three types of dielectric liquid were used: mineral oil Nynas Nytro 10X, synthetic ester Midel 7131 and natural ester Midel en1204. The purpose of the research was to observe and analyze changes in the dielectric properties of these materials. The studies took into account the impact of temperature in the range from 20°C to 100°C, which corresponds to the typical conditions of exploitation of impregnated insulation in power transformers.
PL
W artykule przedstawiono wyniki badań w tzw. spektroskopii dielektrycznej dwóch mieszanin oraz ich składników, tj. bazowych olejów izolujących i cieczy jonowych jako dodatków aktywnych elektrycznie. W pierwszej części badań [1] stwierdzono występowanie efektu ER w obu mieszaninach, gdy poddane były oddziaływaniu zewnętrznego stałego pola elektrycznego o natężeniu E ≤ 0,2 kV ⋅ mm⁻¹. Efekt elektroreologiczny był jednak krótkotrwały i niepowtarzalny na tej samej próbce cieczy, co sugerowało istotne zmiany jej struktury wewnętrznej. Stosując analizator impedancji HP 4192A, oceniono zmienność ich stałych dielektrycznych (ε) oraz rezystancji (R) i konduktywności (σ) w funkcji częstotliwości (f) stałego pola elektrycznego BIAS-u (DC), dla różnych wartości przyłożonego napięcia (U). Wykonano również testy powtarzane na tych samych próbkach mieszanin w celu zaobserwowania, jak pierwotnie przyłożone pole BIAS-u wpływa na dalsze zachowanie cieczy w polu elektrycznym. Na podstawie rezultatów badań uzyskano podstawę potwierdzenia symptomów zmian struktury wewnętrznej mieszanin, będących wynikiem działania zewnętrznego pola elektrycznego, prowadzących do zaniku efektu ER. W celu rozpoznania mechanizmu zaniku efektu ER zostaną przeprowadzone badania mikroskopowe in situ wytworzonych mieszanin poddanych działaniu zewnętrznego pola elektrycznego.
EN
The paper presents the results of investigations of two mixtures and their ingredients i.e. base insulating oils and ionic liquids as electrically active additives using, so called, dielectric spectroscopy. In part 1 of the study [1], the ER effect was found in both mixtures when they were subjected to an external constant electric field with the intensity of E ≤ 0.2 kV ⋅ mm⁻¹. However, the electrorheological effect was short-lived and unique on the same liquid sample, which suggested significant changes in its internal structure. Using the HP 4192 A Hewlett Packard impedance analyzer, the variability of their dielectric constans (ε), as well as the resistance (R) and the conductivity (σ), as a function of the frequency (f) of the constant electric field BIAS-u (DC) was assessed for different values of the applied voltage (U). Repeated tests were also carried out on the same samples of mixtures to observe how the originally applied BIAS field affects the further behavior of the liquid in the electric field. Based on the results of the research, the basis for confirming the symptoms of changes in the internal structure of mixtures, resulting, from the action of an external electric field, leading to the disappearance of the ER effect was obtained. In order to recognize the mechanism of disappearance of the ER effect, in situ microscopic tests of the prepared mixtures, subjected to an external electric field, will be carried out.
PL
W artykule przedstawiono wyniki badań laboratoryjnych wykonanych na próbkach izolacji aramidowej impregnowanej estrami, naturalnym i syntetycznym. Próbki papieru aramidowego poddano procesowi przyspieszonej degradacji termicznej, który polegał na jego wygrzewaniu jeszcze przed impregnacją w temperaturze 250°C przez określony czas. Analizie poddano wpływ stopnia zestarzenia papieru aramidowego na charakterystyki dyspersyjne pojemności i współczynnika strat w zakresie temperatury od 20°C do 100°C.
EN
The paper presents the results of laboratory investigations carried out on aramid insulation impregnated with esters, natural and synthetic. Aramid paper samples were subjected to the process of accelerated thermal degradation, which consisted in its heating still before impregnation in temperature of 250°C for a definite time period. The analysis was subjected to influence of the aramid paper aging degree on dispersion characteristics of capacitance and loss factor in the temperature range from 20°C to 100°C.
PL
W artykule przedstawiono zagadnienia związane z oceną dynamiki wymiany oleju mineralnego na ester syntetyczny w izolacji celulozowej oraz problem oceny zawilgocenia izolacji celulozowej napełnionej mieszaniną oleju mineralnego z estrem syntetycznym. Z badań wynika, że proces wymiany oleju mineralnego na ester syntetyczny jest długotrwały, a ocena zawilgocenia metodą FDS na podstawie wzorców celuloza-olej mineralny skutkuje błędem niedoszacowania.
EN
The article presents issues related to the assessment of the dynamics of exchange of mineral oil to synthetic ester in cellulose insulation, and the problem of moisture evaluating of cellulose insulation filled with a mixture of mineral oil with synthetic ester. The research shows that the process of replacing mineral oil to synthetic ester is long, and the evaluation of moisture using FDS method based on patterns of cellulose-mineral oil results in an underestimation.
6
Content available remote Rozkład zawilgocenia w rdzeniu izolatora przepustowego o izolacji typu RBP
PL
W artykule przedstawiono rozkład zawilgocenia w rdzeniu izolatora przepustowego o izolacji papierowej powleczonej a następnie utwardzonej z użyciem żywicy (izolacja typu RBP – Resin Bonded Paper). Zastosowano dwie metody wyznaczania zawilgocenia, metodę spektroskopii dielektrycznej w dziedzinie częstotliwości oraz metodę Karla-Fischera. Przedstawione w artykule badania, umożliwiły weryfikację wzorca odpowiedzi dielektrycznej izolacji żywicznej, stosowanego przez autorów do oceny zawilgocenia izolatorów o izolacji typu RBP.
EN
The article presents the distribution of moisture in the core of the bushing, insulated by resin coated and then curing paper (RBP - Resin Bonded Paper). Two methods of determining moisture, the method of spectroscopy in the frequency domain and Karl-Fischer method were used. Presented studies made it possible to verify the insulation dielectric response pattern of the resin-paper insulation, which is used by the authors to assess the moisture content in RBP bushings.
PL
Spektroskopia dielektryczna opisuje właściwości dielektryczne próbki materiału w funkcji częstotliwości. Takimi materiałami mogą być obiekty agrofizyczne, np. gleba, owoce, warzywa, półprodukty i produkty przemysłu spożywczego, ziarno itp. Techniki spektroskopii dielektrycznej umożliwiają pomiar nieniszczący oraz nieinwazyjny obiektów agrofizycznych dając szybką ocenę ich wilgotności oraz jakości.
EN
The paper presents result of analysis of dielectric response in frequency domain for several power transformers. The main goal of this analysis is determination of moisture content in solid insulation. It is result from the authors experiences that same basics information required to correct analysis are unavailable or uncertain in many cases. Authors carried out analysis of dielectric response for power transformers taking into consideration the fact that the geometry and temperature can differ from initially assumed.
PL
W artykule przedstawiono wyniki analiz odpowiedzi dielektrycznej izolacji kilkunastu transformatorów energetycznych, w wyniku których otrzymuje się informacje na temat zawilgocenia izolacji stałej. Jednakże często dane wejściowe niezbędne do przeprowadzenia analizy odpowiedzi dielektrycznej są trudnodostępne lub obarczone dużym błędem. Przeprowadzono zatem analizę odpowiedzi dielektrycznej przy założeniu, że kluczowe parametry (temperatura i geometria izolacji) nie są dokładnie znane. Oceniono wpływ tych czynników na uzyskiwane wyniki analiz.
PL
Artykuł przedstawia analizę możliwości zastosowania techniki FDS (Frequency Domain Spectroscopy) do oceny zawilgocenia izolacji stałej transformatorów energetycznych, których uzwojenie dolnego napięcia wykonane jest w technologii przewodów transponowanych izolowanych lakierami żywicznymi. Badaniom poddano transformator energetyczny o izolacji lakier-papier-olej oraz dwa rodzaje lakieru. Stwierdzono, że cienka warstwa lakieru zastosowana w analizowanym transformatorze nie wpływa znacząco na odpowiedź dielektryczną.
EN
The paper presents an analysis of possibility of the FDS technique application for moisture evaluation in power transformers with varnished transposed wires. The power transformer and two types of insulating varnish were investigated. The author concluded that thin layer of varnish doesn't have the significant influence on the dielectric response of transformer insulation.
10
Content available remote Study of the relaxor behaviour in Ba0.68Na0.32Ti0.68Nb0.32O3 ceramic
EN
Purpose: The purpose of this work was to synthesize a new ceramic solid solution Ba0.68Na0.32Ti0.68Nb0.32O3 (BNTN32), as well as to measure and analyse its dielectric properties within the temperature range 123 K-473 K, where dielectrically active phase transition was supposed to occur. Design/methodology/approach: The new ceramic composition was prepared by means of conventional method. Dependence of phase transition features on temperature and frequency of measuring field were measured using dielectric spectroscopy method within the frequency range from 20 Hz to 1 MHz. Findings: The electric susceptibility along with temperature decrease generally rises up and has transient dispersion vanishing at about 230 K. At higher and low temperatures, frequency dependence of dispersion differs in character: at temperatures at ~400 K, low frequency values dominate. Dielectric energy losses are very high at ~high temperature, they decline down while temperature decrease, and at about 200 K range its frequency dependence is reversed and less scattered with maximum at ~150 K. The whole transition of ferroelectric - paraelectric (FE - PE) type can be described by means of Curie-Weiss law and it gets diffused character. Research limitations/implications: For modelling purposes the structure parameters of BNTN32 have to be measured by X-ray diffraction in order to establish the dielectric/structural activities of transitions taking place within used the temperature range. Additionally, dielectric measurements within broader frequency range up to 1.8 GHz will be performed. Originality/value: The new type of ceramic material was prepared with interesting dielectric properties. Dispersion reverse of energy losses activated thermally and low frequency memory of barium titanate (BT) transition effect visible at ~400 K is to be a subject of modelling further work.
11
EN
Purpose: The purpose of this work was to measure and investigate dielectric properties of new material, polycrystalline solid solution Ba0.96Na0.04Ti0.96Nb0.04O3 (BNTN4) within the temperature range 153 K-473 K. Design/methodology/approach: The dielectric spectroscopy method has been applied to measure dielectric and electric parameters within the frequencies from 20 Hz to 1 MHz. Findings: The dielectric permittivity (&epsilon') dependence on temperature (T) within the range of 473 K-225 K consist of two components: the reversly proportional one and the second one in the form of small local, transient peak at about 400 K. The global maximum is frequency dependent and above &sim 400 K along the T decrease, the dispersion of &epsilon' is initiated and low frequency dispersion of &epsilon' prevails below 250 K. Energy losses measure (&epsilon"), correlated with &epsilon'(T), is generally shifted towards lower T values. Its frequency dependence undergoes inversion which develops with T decrease and is initiated at about 370 K. The whole temperature induced phase transition turned out to be of relaxor kind and diffused process. The detailed analysis of this transition and its features was performed. Research limitations/implications: In order to determine the details of polycrystalline structure of BNTN4 new material for modelling of ferroelectric properties the precise X-ray diffraction measurements should be performed as function of T. The nature of ferroelectric - paraelectric (FE - PE) transition diffusive character will be studied by means of dielectric measurements within frequency range 1 MHz-1.8 GHz. Originality/value: The new kind of ferroelectric solid solution (BNTN4) was synthesized. The specific features of this material at low T range involves among others, the T-dependent dispersion of dielectric properties on low T side of broad &epsilon'(T) peak.
12
Content available remote Dielectric spectroscopy study of Ba0.98Na0.02Ti0.98Nb0.02O3 ceramic
EN
Purpose: The purpose of this work was to investigate dielectric properties of new ceramic solid solution Ba0.98Na0.02Ti0.98Nb0.02O3 (BNTN2) within the temperature range 153 K - 473 K. Design/methodology/approach: The dielectric spectroscopy method was applied to measure frequency and temperature dependence of complex dielectric permittivity, complex admittance, phase angle. The frequency dependence of ac conductivity at constant temperature was analysed as well as reciprocal permittivity and dielectric modulus as functions of temperature and frequency were compared. The Curie-Weiss rule and its generalized formula were applied in outcomes analysis. Findings: The ferroelectric - paraelectric (FE - PE) phase transition occurring in BNTN2 was found as having diffusive nature. In the paraelectric phase at about 400 K the diffusivity of transition step is correlated with the same kind of transition in BaTiO3 (BT) (transition of FE - PE type) and with structural transition occurring in NaNbO3 (NN). Within the temperature range below Tm = 308 K, dependences of dielectric properties of BNTN2 ceramic on temperature and frequency was found as having relaxor type of behaviour. Research limitations/implications: The confirmations of achieved findings will be possible by more precise BNTN2 structure determination by means X-ray diffraction. Also closer explanation of FE - PE phase transition can be performed by dielectric measurements within broader frequency range up to 1.8 GHz ( diffusive versus relaxor character of transition). Originality/value: The new solid solution of BNTN2 was prepared. The structure of this material was characterized as dielectrically active and having FE - PE phase transition which was described.
13
Content available remote Characteristics of phase transitions in Ba0.995Na0.005Ti0.995Nb0.005O3 ceramic
EN
Purpose: The purpose of this work was to prepare ceramic material BaTiO3 (BT) as well as solid solution of Ba1-xNaxTi1-xNbxO3 (for x = 0.005) (BNTN05) type and correlate their structural (polycrystalline) properties with phase transitions within the temperature range from 153 K to 473 K. Design/methodology/approach: The dielectric spectroscopy method has been applied to measure dielectric and electric parameters within the frequency from 20 Hz to 1 MHz. Findings: The measured dependences of: complex dielectric permittivity and its phase angle (between measuring voltage and current response) points out on complex phase transition character for both investigated materials. Experimental outcomes for BT are consistent with those already published. Achieved results in the case of BNTN05 are published here for the first time. They were correlated with those of BT as unmodified one. Phase transitions parameters of both materials were described by means of generalised Curie-Weiss rule including step of phase transition diffusivity. Small amount (x = 0.005) of NaNbO3 (NN) admixture makes sharp, classical transition of first order kind occurring in the case of BT, to be a diffusive one and shifted by about 20 K towards lower temperatures. Research limitations/implications: Further investigations should be carried out in a broaden frequency range (up to 1.8 GHz) in order to establish the influence of network dynamics on ferroelectric-paraelectric phase transition as well as others low-temperature phase transitions. In order to complete structural data of new BNTN05 material additional X-ray and calorimetric measurements will be performed. Originality/value: The same method and components were used for preparation of BT and new BNTN05 material. Thermally induced phase transitions, mutually related in both materials were measured and described.
14
Content available remote Relaxor properties of Ba1-xNaxTi1-xNbxO3 at low temperatures
EN
Purpose: The purpose of this paper is to investigate ferroelectric relaxor behavior of polycrystalline solid solutions of Ba1-xNaxTi1-xNbxO3 (for x = 0.3 and x = 0.4) at low temperatures (113 K - 473 K). Design/methodology/approach: The dielectric spectroscopy method has been applied to measure dielectric and electric parameters within the frequencies from 20 Hz to 1 MHz. Findings: Temperature dependences of real (ε') and imaginary (ε'') parts of dielectric permittivity confirm relaxor type of polarization behavior for both investigated materials. Experimental findings are in good agreement with data published in literature. Diffused phase transition of relaxor character is analysed in the terms of departure from Curie-Weiss rule. A dependence of the temperature related to the maximum of dielectric permittivity on the frequency has activated character. Different thermal activation energies found for the investigated materials may be related to their different microstructures. Research limitations/implications: Further investigations should be carried on in a broaden frequency range (up to 1.8 GHz) in order to establish an influence of network dynamics on ferroelectric-paraelectric phase transition. Originality/value: Relaxor behaviour in polycrystalline solid solution of Ba1-xNaxTi1-xNbxO3 (for x = 0.3 and x = 0.4) is described.
15
Content available remote Characterization of Ba1-xNaxTi1-xNbxO3 ceramic by dielectric spectroscopy
EN
Purpose: The purpose of this paper was characterization of electric properties of polycrystalline nanograin solid solution of Ba1-xNaxTi1-xNbxO3, x = 0.65 (BNTN65) within the temperature range 153 K-573 K. Design/methodology/approach: The dielectric spectroscopy method (DSM) has been applied to measure dielectric and electric parameters within frequency range from 20 Hz to 1 MHz and within the temperature range of diffused ferroelectric - paraelectric transition and above within paraelectric state. Findings: Analysis of temperature and frequency dependences of real (ε') and imaginary (ε'') parts of dielectric permittivity and electric modulus provided the new details about specific features of paraelectric properties of ceramic BNTN65 sample. They involve weak relaxational diffused processes as well as dielectric losses. Specific two steps increase of ε' values turned out to be frequency dependent and of thermal activated character. Research limitations/implications: Above specified new details of polarizability of paraelectric phase for ceramic sample should be treated as a base for new modelling approach and quantitative description of polar clusters dependence on temperature and frequency. Originality/value: For the first time, details of polarizability of paraelectric phase, which are temperature and frequency dependent in such specific manner were described.
16
EN
In this paper dispersive curves were measured by dc and ac methods. An attempt has been undertaken to verify the hypothesis that a dielectric containing space charge, examined by actual value method, gives different measurement results from the ones, examined by time response method. If the measurement results obtained by the both methods for the same sample do not differ from each other, it means that in the examined object no space charge exists.
PL
W niniejszej pracy zmierzono charakterystyki dyspersyjne metodami stało- i zmiennoprądowymi. Podjęto próbę zweryfikowania hipotezy, że dielektryk zawierający ładunek przestrzenny, badany metodą wartości chwilowych, daje inne wyniki pomiarowe niż badany metodą czasowej odpowiedzi. Jeżeli natomiast wyniki pomiarowe uzyskane obiema metodami na tych samych próbkach pokrywają się, oznacza to, że w badanym obiekcie nie występuje ładunek przestrzenny.
PL
W artykule opisano melody diagnostyczne służące do oceny stopnia zawilgocenia izolacji papierowo-olejowej transformatora energetycznego. Szczegółowo omówiono podstawowe założenia teoretyczne metod RYM i FDS i sposoby poprawy ich wiarygodności. Przedstawiono również wyniki badań wykonanych na populacji transformatorów pracujących w sieci elektroenergetycznej. Dodatkowo w artykule opisano groźne zjawisko tzw. bubble effect, które może wystąpić w zawilgoconym trans forma torze.
EN
The paper describes diagnostic methods for moisture content evaluation in paper-oil insulation of power transformer. Particulary, the theoretical fundamentals of RVM and FDS methods and possibilities of their improving were discussed. Then, the results of measurements on the population of power transformer installed in the power grid were presented. Additionally, in the article a very dangerous phenomenon i.e. bubble effect, which can occur in moistured transformer, were described.
PL
W artykule przedstawiono zebrane wyniki badań transformatorów przeprowadzonych w Polsce, Niemczech i Szwecji w ramach międzynarodowego projektu badawczego REDIATOOL. W znakomitej większości były to transformatory zainstalowane w sieciach przesyłowych, mniejszą część stanowiły transformatory blokowe, rozdzielcze i potrzeb własnych. Spośród wszystkich badanych na przestrzeni 3 lat transformatorów, osiem jednostek badano powtórnie po upływie co najmniej roku. Przedstawione w pracy zestawienia statystyczne dowodzą, że dla jednostek podobnych typów, eksploatowanych według ustalonych zasad, można określić wiek transformatora, po przekroczeniu którego, procesy starzeniowe w izolacji zachodzą znacznie szybciej niż dla jednostek nowych.
EN
The paper describes the set of investigation results carried out in Poland, German and Sweden collected within a framework of international research project -REDIATOOL. The investigations were done on transmission transformers, as well as generator step-up (GSU) transformers, distribution and internal load transformers. The eight units have been analysed twice in period of 3 years of project execution. Presented statistical overview proves that for the similar types of transformers which operate in similar condition it is possible to estimate the transformer age after which the aging processes occur faster then for new units.
PL
W niniejszej pracy przedstawiono elektryczne właściwości cienkich warstw PTFE uzyskanych metodą polimeryzacji plazmowej. Wykonano pomiary współczynnika strat dielektrycznych tg delta, a także pomiary prądów przejściowych (absorpcji i resorpcji) w funkcji napięcia polaryzującego próbkę. Zastosowano metodę czasowej odpowiedzi w celu uzyskania niskoczęstotliwościowych charakterystyk współczynnika strat całkowitych i polaryzacyjnych. Stwierdzono istotny wpływ ładunku przestrzennego na badane krzywe.
EN
This paper presents a method for plassma-assisted deposition of PTFE thin films. Dielectric loss coefficient tg delta and transient currents (absorption and resorption) versus polarization voltage were tested. Low-frequency characteristics used by Hamon approximation method. The results confirmed the considerable influence of space charge on electrical properties PTFE thin films.
PL
W artykule przedstawiono wyniki badań prototypowego silnika indukcyjnego o izolacji szklo-mika-epoksyd przeznaczonego do pracy z pompą ciekłego metanu w warunkach kriogenicznych. Badania prowadzono na pojedynczych cewkach oraz na prototypowym silniku. Ocena właściwości izolacji obejmowała przede wszystkim odporność na działanie niskiej temperatury oraz szoku termicznego. Badania przeprowadzono z wykorzystaniem spektroskopii dielektrycznej oraz pomiarów wyładowań niezupełnych.
EN
The paper presents results of investigation of the prototype inductive motor with a glass-mica-epoxy insulation assigned to work with a liquid methane pump in cryogenic condition. The investigation were carried out on single coils and the prototype motor. The assessment of insulation properties consisted of low temperature and temperature shock resistance. The investigations were done using dielectric spectroscopy and partial discharge measurement.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.