Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 18

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  spectrophotometer
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The article presents the results of research on the influence of irradiation of fiber-cement boards with UV radiation residing in the aging chamber. Two fibrous cement slabs were tested. One was a plate in the aging chamber and the other was a reference plate. In the tests, a spectrophotometer was used to assess the color change, while the non-destructive method SEM were used to assess the process of destruction and changes taking place in the structure of the panels. The results that were obtained, allowed to observe visible changes in the process of destruction of boards subjected to aging tests. In addition, it has been shown that UV radiation not only affects the color change of such plates, but also significantly affects the changes occurring in the structure of the panels in question.
PL
W artykule przedstawiono wyniki badań wpływu naświetlania płyt włóknisto-cementowych promieniowaniem UV przebywających w komorze starzeniowej. Badaniom poddano dwie płyty włóknisto-cementowe. Jedną stanowiła płyta przebywająca w komorze starzeniowej, a drugą płyta referencyjna. W badaniach do oceny zmiany barwy użyto spektrofotometru, z kolei do oceny procesu niszczenia i zmian zachodzących w strukturze płyt użyto metody SEM. Rezultaty które uzyskano pozwoliły zaobserwować widoczne zmiany w procesie niszczenia płyt poddanych badaniom starzeniowym. Ponadto wykazano, że promieniowanie UV ma wpływ nie tylko na zmianę zabarwienia takich płyt, ale także wpływa istotnie na zmiany zachodzące w strukturze przedmiotowych płyt.
EN
The performance of Vigna unguiculata coagulant (VUC) for colour removal from acid dye was investigated in this study. The proximate, structure and morphology of the coagulant were investigated using standard official methods, Fourier-Transform Infrared (FTIR) spectrometer and scanning electron microscopy (SEM), respectively. Response surface methodology (RSM) using face-centred central composite design (FCCD) optimized four process variables including pH, coagulant dosage, dye concentration and time. The colour removal efficiency obtained from the optimization analysis was 99.26% at process conditions of pH 2, coagulant dosage 256.09 mg/l, dye concentration 16.7 mg/l and time 540 min. The verification experiments agreed with the predicted values having a standard error value of 1.96%. Overlay contour plot established optimum areas where the predicted response variable is in an acceptable range (≥ 70%) with respect to optimum conditions. The FCCD approach was appropriate for optimizing the process giving higher removal efficiency when compared to the main effect plots.
PL
Badania dotyczą wpływu stopnia tłumienia promieniowania świetlnego przez powierzchnię szklaną opakowania spożywczego. Badania zostały przeprowadzone dla źródeł świtała naturalnego i sztucznego, którego promieniowanie przenikało szkło kolorowane. Analizowane szkło w niewielkim stopniu przepuszcza całe spektrum światła widzialnego, szczególnie dotyczy to składowej widma światła fioletowej a jednocześnie przepuszcza pewną części promieniowania w zakresie podczerwieni.
EN
The study deals with the effect of light radiation suppression on the glass surface of the food packaging. The research was conducted for natural and artificial light sources whose radiation penetrated colored glass. The analyzed glass transmits a small amount of visible light, especially the composition of the violet light spectrum, and at the same time transmits some of the infrared radiation. Photometric analysis was conducted of the structure of selected types of packaging used in the processing and cosmetic industries.
PL
Za pomocą linii technologicznej do współwytłaczania otrzymano dwuwarstwowe rury o różnej grubości warstwy zewnętrznej i wewnętrznej, wykorzystywane w branży reklamy świetlnej. Celem takiej budowy wytłoczyny jest przede wszystkim zwiększenie odkształcalności, jak i uzyskanie odpowiedniego rozproszenia światła. Otrzymane rury poddano badaniom, określając ich wymiary poprzeczne - grubość poszczególnych warstw, wytrzymałość na zginanie i kąt ugięcia z wykorzystaniem aparatu Dynstat. Próbki wycięte z otrzymanych wytłoczyn poddano również badaniom pomiaru natężenia barwy przepuszczanego światła z użyciem spektrofotometru.
EN
Using a line for double-layer co-extrusion to give pipes of different thicknesses inner and outer layer, used in the field of illuminated advertising. The purpose of this design of the extrudate is mainly to increase the deformability and achieve proper dispersion of the light. The resulting pipe was tested, the dimensions of the cross - thickness of the individual layers, the bending strength and the deflection angle using a Dynstat device. Samples cut from the extrudate were subjected to the tests measuring the color intensity of the light transmitted by a spectrophotometer.
PL
Praca opisuje konstrukcję oraz testy urządzenia zbierającego skropliny wydychanego powietrza, w których znadują się biomarkery chorób układu oddechowego. Celem urządzenia jest zwiększenie koncentracji biomarkerów, które mogą być następnie wykrywane za pomocą przygotowanego spektrofotometru i pH-metru. W pracy przedstawiono szczegółowo konstrukcję oraz sposób analizy zbieranych próbek. Skuteczność działania urządzenia przetestowano na grupie ochotników oraz, w przeciągu wybranego okresu, na pojedynczej osobie. Uzyskane wyniki wskazują, że zaproponowane rozwiązania konstrukcyjne pozwalają koncentrować wybrane biomarkery (np. stężenie tlenków NOx, wartość pH) do poziomu pozwalającego na skuteczną detekcję.
EN
This study describes the construction and testing of the condensate collection device within the exhaled to detect biomarkers of respiratory diseases. The device increased concentration of the biomarkers, detected by analytical methods (spectrophotometer). The paper presents in detail the analysis method of the collected samples. The device was tested by collecting breaths of volunteers. The results confirmed that the device can collect the selected biomarkers and analyze using the prepared spectrophotometer.
6
EN
The destructive effects of sun UV radiation on human skins are now very clear to everyone. Most of the present studies were focused on the fabrics’ structural parameters such as density, warp and weft yarns finenesses, fabric pattern and printing or finishing treatments applied to the fabrics. The aim of this work is achieving a technique through which the produced fabrics possess a higher UV-protection ability. For this purpose, two different metals including aluminium and copper yarns were employed in fabrics production process and their effects on UV-protection ability of the produced fabrics were investigated. Six different fabric samples comprised of either cotton/polyester, nylon yarns as the warp yarns as well as either aluminium or copper yarns as the weft yarns were produced. Using the spectrophotometer technique, which is known as one of the UPF measuring method, the absorbency and reflectivity of fabrics within the specified range of electromagnetic waves (specially the UV radiation) were determined. The results illustrated that the higher UV absorbency was related to the fabric possessing the copper yarns in their structures. It was concluded that the absorption ability of nylon fabrics is higher than that of the cotton/polyester samples.
PL
W pracy zaprezentowano wybrane zagadnienia, które dotyczą techniki badań i pomiarów spektrofotometrem. Opisano wpływ przełączania źródeł promieniowania optycznego na wartość sygnału w torze pomiarowym spektrofotometru dwuwiązkowego. Zamieszczone wyniki obrazują widmo natężenia promieniowania optycznego w torze S (Sample) i R (Reference) przyrządu oraz transmitancję optyczną i jej fluktuacje. Rejestracji widma dokonano w zakresie długości fali UV, VIS i NIR , tj. od 190 nm do 900 nm.
EN
Some selected questions concerned the technology and measurements with the spectrophotometer are presented. Influence of the optical radiation sources switching over on the signal value in the measuring line of double-beam spectrophotometer is described. The presented results show the spectrum of the optical radiation intensity in the device S (Sample) and R (Reference) lines as well as the optical transmittance and its fluctuations. The spectrum was recording in the range including the wavelengths from 190 nm to 900 nm.
PL
W artykule podjęta została próba zastosowania nowej technologii pomiaru zmiany barwy z wykorzystaniem urządzenia DigiEye. Porównanie DigiEye z powszechnie wykorzystywanym w przemyśle spektrofotometrem Mecbeth 2020 miało na celu określenie zależności między wskazaniami obu przyrządów pomiarowych. Próbki do oceny zmiany barwy na obu urządzeniach poddano naświetlaniu w aparacie Xenotest 150. Proces starzenia został zrealizowany wg metody niebieskiej skali. Wyniki badań uzyskano poprzez pomiar przed testem starzenia oraz po każdym zwolnieniu przesłony podczas naświetlania badanych próbek. Analiza wyników zmiany barwy została wykonana w systemie barwnym CIE L*a*b*. Badania przeprowadzono dla tkanin poliestrowych przeznaczonych na wierzchnie wyroby odzieżowe.
EN
In the paper there is presented a trial of application of new measurement principle of colour change with the use of DigiEye device. Comparison of DigiEye with commonly use in the textile industry spectrophotometer Macbeth 2020 was an aim of determination of relationship between parameters of both measurement systems. Samples for the colour change assessment on both measurement systems were first aged in the Xenotest 150. Ageing process was done according to the method of blues scale. Results were obtained by the colour measurement devices before and after the ageing test each releasing the diaphragms during exposing the examined samples on the light. Result of colour change were obtained in the colour system CIE L*a*b*. The measurements were done for PES fabrics destined on the outer layers of clothing.
9
PL
Obecnie najczęściej wykorzystywanym narzędziem do pomiaru barwy są spektrofotometry. W połączeniu z odpowiednim oprogramowaniem pozwalają uzyskać informację o parametrach barwy, porównać dostarczoną partię produktu z wzorcem, dobrać alternatywny kolor aplikacji, modyfikować projekty graficzne. Ich stosowanie poprawia możliwości nadzoru technologicznego, uniezależnia wynik od subiektywnej oceny obserwatora oraz skraca czas doboru składu aplikacji. Niniejsze opracowanie ma na celu przybliżyć metodykę pomiaru spektrofotometrycznego wraz z jej podstawami oraz wskazać praktyczne wykorzystanie urządzenia w pracach laboratorium technologicznego.
EN
Nowadays spectrophotometers are mostly used in measurements of colour. According to the adequate software they give us the information about parameters of colour, make possible to compare a new product with the standard sample, to choose correctly alternative colour of the application, and to modify graphics and projects. Using them, it is possible to improve technological control of the processes, taking the result independent on the observer and cutting the time necessary for changing in application’s components. The purpose of this paper is to make closer the spectrophotometric measurement method and pointing the practical use in technological laboratory.
PL
W artykule przedstawiono badania nad możliwością wykorzystania spektrofotometru w pomiarach koloru i klasyfikacji bawełny. Dotychczas kolor bawełny jest oceniany za pomocą linii HVI (High Volume Instrument). Współrzędne barwy: współczynnik odbicia światła (Rd) i stopień zażółcenia (+b) wg HVI są specyficzne dla bawełny, natomiast nie stosuje się ich do oceny barwy innych materiałów. Tymczasem na całym świecie w pomiarach barwy stosowane są składowe barwy w trójwymiarowej przestrzeni barwowej CIELab. Przeprowadzone badania pozwoliły na wyznaczenie równań regresji, które umożliwiają obliczanie wskaźników (Rd) i (+b) w oparciu o wartości współrzędnych barwy L* i b* otrzymywane za pomocą spektrofotometru.
EN
The colour grade of cotton is determined by a degree of the reflectance (Rd) and yellowness (+b). These parameters are instrumentally measured by the HVI. Both (Rd) and (+b) are specific for cotton, whereas all over the world colour assessment is performed in the globally recognized CIE L*a*b* colour system. The aim of this work was to analyse application of a spectrophotometer for cotton colour assessment and colour grading. 48 cotton samples of different origin were measured in the range of their colour parameters by means of both HVI and spectrophotometer Datacolor 650. Regression analysis carried out on a basis of the experimental data allowed determining equations which enabled calculation of (Rd) and (+b) parameters on a basis of the L* and b* results obtained from the spectrophotometer. Experimental verification based on 34 cotton samples different than those used for the model building confirmed the good quality of predicting the values of the (Rd) and (+b) parameters by means of the elaborated regression equations.
11
Content available remote Important aspects of cotton colour measurement
EN
Colour is the basic criterion of cotton classification into cotton grade according to the Universal Cotton Standards. It also reflects the quality of other non-U.S. grown cotton. For years the quality of cotton has been assessed in an organoleptic way by cotton classers. Today there are plans to replace subjective visual grading by objective instrumental measurement. The colour grade of cotton is determined by the degree of reflectance (Rd) and the yellowness (+b), which are measured instrumentally using an High Volume Instrument (HVI). Some efforts undertaken have aimed at application of a spectrophotometer for cotton color measurement. The aim of this work was to investigate some of the problems of cotton color measurement. A comparison of the classer and HVI color grading was carried out for 32 cotton samples of non-U.S. origin. HVI measurement was performed using two HVI 900 systems. Agreement between the classer and HVI grading was not high, nevertheless it was comparable with that reported in literature, between the classer and HVI grading for U.S. cotton. Next cotton color measurement was conducted by means of an HVI 900 and a Datacolor 650 spectrophotometer. The results confirmed a strong correlation between the (Rd) from the HVI and the CIE L* from the spectrophotometer.
PL
Kolor jest podstawowym kryterium klasyfikacji bawełny. Przez lata kolor bawełny oceniany był organoleptycznie przez odpowiednio wyszkolonych klasyfikatorów. W latach 70 pomiar barwy bawełny został zinstrumentalizowany. Linia HVI (High Volume Instrument) do automatycznej oceny włókien bawełny wyposażona jest w kolorymetr, za pomocą którego wyznacza się dwa wskaźniki charakteryzujące barwę bawełny: stopień zażółcenia (+b) i stopień odbicia światła (Rd). Oba parametry są kryteriami oficjalnej klasyfikacji bawełny w Stanach Zjednoczonych, będących wiodącym światowym producentem i eksporterem bawełny. Podejmowane są badania, których celem jest zastosowanie spektrofotometru do oceny koloru i klasyfikacji bawełny.Celem pracy było badanie wybranych zagadnień związanych z pomiarem koloru bawełny. Na podstawie oceny 32 marek bawełny pochodzących z różnych regionów uprawy wykonano analizę porównawczą klasyfikacji organoleptycznej i instrumentalnej - bazującej na wynikach pomiaru koloru za pomocą linii HVI. Wykonano również badania porównawcze koloru bawełny za pomocą linii HVI i spektrofotometru Datacolor 650. Badania 68 marek bawełny potwierdziły silną i statystycznie istotną zależność korelacyjna pomiędzy stopniem odbicia światła (Rd) wg linii HVI, a jasnością L wg spektrofotometru. Oceniono również wpływ klasy koloru i kategorii koloru bawełny na wartość współrzędnych koloru wyznaczanych za pomocą spektrofotometru.
PL
W artykule opisano spektrofotometryczną metodę określania temperatury łuku elektrycznego palącego się w szczelinie międzystykowej łącznika na podstawie zarejestrowanych widm ciągłych, oraz wpływ rodzaju materiału styków i ich cech konstrukcyjnych na jej wartość.
EN
The article presents a spectrophotometric method for determining temperature of electric arc burning in an inter-contact gap of a switch based on recorded continuous spectra. Influence of the material and design of the contacts on the temperature values is also discussed.
PL
Badano wpływ warunków atmosferycznych na trwałość (stabilność) organicznych pigmentów ftalocyjaninowych, nitrozowych kompleksów metalicznych, diketopirolopirolowych i tetrachloroizoindolinowych w standardowym spoiwie winylowo-akrylowym, w ciągu 12 tygodni. Zmiany barwy określano przy użyciu spektrofotometru X-Rite Master Color oraz reflektografu UV-Vis. Dla porównania testowane pigmenty poddano przyspieszonemu starzeniu w komorze ksenonowej, kontrolując spektroskopowo (IR) zmiany ich struktury. Stwierdzono zróżnicowaną podatność pigmentów stosowanych do wewnętrznych i zewnętrznych wymalowań na kompleksowe działanie światła słonecznego i zanieczyszczeń atmosfery (polutantów).
EN
Stability of phthalocyanine, 1-nitroso-2-naphthol Fe, Co, and Mn complexes, diketopyrrolopyrrole, and tetrachloroisoindolinone used alone and as pigments (0.5 or 1%) in a standard vinyl-acrylic paint, was examd. on a 12-week (June– Sept. 2003) outdoor and indoor exposures in terms of color change detd. by an X-Rite spectrophotometer and pigment’s structure change detd. by UV-VIS and IR spectroscopy. Coatings applied to glass conditioned 14 days at 23±2°C, RH 50±2%, were exposed to the atm. at Oświęcim, PL. Nondispersed pigments were lit for 168 hrs. with a 280-nm Xe lamp at 55°C and then IR analyzed. In IR terms, the Fe complex was most resistant, and the other pigments were fully resistant, to accelerated aging. The Co and Mn complexes were least resistant to the 12-week outdoor exposure. Most fading were the diketo and the tetrachloro pigments, but the Xe lamp irradiation produced no major structure changes. The color changes in the tetrachloro pigments produced in the12-week test were invisible to the human eye.
EN
Evaluation of personal inhalation exposure to methylene diphenyl diisocyanate (MDI) among 39 employees, working in the window fixation and window glue processes in an automobile manufacturing company was performed. This study was conducted for both case and control groups. After sampling and sample preparation processes, MDI was determined with a UV-VIS spectrophotometer at 590 nm; the lung function was assessed with a digital spirometer, too. The average concentration of MDI in the window fixation, and window glue workplaces were 34.53 and 27.37 μg/m3, respectively, which was lower than the threshold limit value (TLV) recommended by the American Conference of Governmental Industrial Hygienists (ACGIH) (51 μg/m3). Respiratory symptoms in the exposed group were significantly different compared to the unexposed group (p < .05). Lung capacities in the case group were lower than in the control group (p < .05). Therefore, MDI can be easily measured making it possible to evaluate the adverse effects caused by occupational exposure.
PL
W artykule podano wybrane informacje na temat stosowania mgły oleju mineralnego do smarowania mechanizmów maszyn, a także obowiązujące w Polsce wartości dopuszczalnych stężeń olejów mineralnych i omówiono metody stosowane do oznaczania mgły olejowej w powietrzu na stanowiskach pracy. Na podstawie wyników badań rozpoznawczych zaproponowano alternatywny, wagowy sposób pomiaru ilości oleju osadzającego się na filtrach z pobranych próbek powietrza, łatwiejszy w realizacji i mniej kosztowny od obecnie stosowanego sposobu pomiaru za pomocą spektrofotometru.
EN
This paper presents selected information on the use of mineral oil mist in lubricating machines. It also discusses information on permissible concentrations of mineral oils that are obligatory in Poland and methods used in determining oil mist in workplace air. On the basis of recognition tests, an alternative gravimetric method of measurement is proposed. It consist in a gravimetric determination of the quantity of oil deposited in filters from air samples. This method is easier and less expensive than spectrometric measurement method which has been used so far.
16
Content available remote Examination of haemodialysis efficiency with the aid of two-beam spectrophometry
EN
The paper describes the application of two beam spectrophotometry in monitoring the efficiency of haemodialysis treatment of patients with renal failure. The special attention was given to the proper choice of the wavelength of dialysate probing light what results in the highest possible sensitivity of dialysis monitoring.
PL
W pracy opisano sposób wykorzystania dwuwiązkowej spektrofotometrii w obszarze ultrafioletu do monitorowania skuteczności procesu hemodializy prowadzonej u pacjentów z powodu niewydolności nerek. W szczególności skupiono się nad doborem zakresu długości fal sondujących dializat pod kątem uzyskania najlepszej czułości aparatury monitorującej przebieg dializy.
17
Content available remote Kontrola barwy ceramicznych farb naszkliwnych.
EN
We report the design and assembly of a fast spectrophotometer to monitor fast chemical reactions. The system incorporates coupled charge detector (CCD) technology, enabling the instantaneous capture of complete optical spectra in a time scale as short as few microseconds. For demonstration purposes, the degradation of one of the pesticides (benomyl) was monitored using this system.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.