Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  spatial filter
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
To investigate the optimal filter settings for pre-processing of Movement Related Cortical Potentials (MRCP) for the detection through EEG in single trial, we have proposed a novel Non-Linear Optimized Spatial Filter (NL-SF) and compared it to the Optimized Spatial Filtering (OSF) used in literature. MRCPs from EEG recordings are emphasized, calculating the optimal non-linear combination of channels which isolates the signal of interest. The method is applied to EEG data recorded from 16 healthy patients either executing or imagining 50 self-paced upper limb movements (palmar grasp). MRCPs have been identified from the outputs of the two filters by matching with a template built by averaging responses to movement intentions in the training set. NL-SF had a median accuracy on the overall dataset of 84.6%, which is significantly better than that of OSF (i.e., 76.9%). Being a filter and feasible for self-paced applications, it could be of interest in online BCI system design.
PL
Pomiary śladowych stężeń gazów są ważne dla przemysłu, ochrony środowiska, medycyny oraz bezpieczeństwa. Pomiary te można zrealizować z wykorzystaniem laserowej spektroskopii absorpcyjnej z modulacją długości fali lasera półprzewodnikowego. W pracy opisane zostały badania istotnych parametrów, wykorzystanego do pomiarów stężeń gazów, kwantowego lasera kaskadowego. Podczas badań wyznaczono charakterystyki mocy lasera w funkcji natężenia prądu zasilającego. Zostały one zarejestrowane w wybranych temperaturach jego pracy. Następnie zbadano charakterystykę strojenia częstotliwościowego lasera za pomocą germanowego etalonu Fabry -Perot. Ponadto przedstawiona została metoda poprawy parametrów wiązki lasera. Metoda ta polegała na zastosowaniu w układzie filtra przestrzennego, którego zasada działania i konstrukcja zostały opisane w niniejszej pracy.
EN
Setups for measuring the concentrations of gases are important from a practical point of view. These measurements can be performed using wavelength modulation absorption spectroscopy. This paper describes the study of important parameters of quantum cascade laser, used for measuring concentrations of gases. During the tests the characteristics of the laser power as a function of current supply were measured at selected work temperatures. Then, examined changes in the power of the laser radiation in response to the modulation of supply current. Furthermore, the a spatial filter has been applied to achieve a Gaussian profile of the laser intensity. Filter operation procedure and its construction were also described.
EN
In last few decades it can be observed that there is a significant growth of the interest in the structural health monitoring (SHM) systems development and applications. Unfortunately many authors focuses only on the damage detection and other activities related with diagnosis of fault. Meanwhile, classical SHM system by definition should have in addition to a diagnostic module also module for load monitoring. This load can be measured, but easier and cheaper is to identify it from the measured response of the object. Often it is the only practical possibility to monitor the excitation. The paper presents a trial to apply a spatial filter based on operational deflection shapes (ODS) to force identification. The idea of spatial filter will be shown together with the method of force reconstruction. The simulation verification and comparison with classical modal filter will be also provided.
PL
W kilku ostatnich dziesięcioleciach można zaobserwować znaczny wzrost zainteresowania budową i zastosowaniami układów monitorowania stanu obiektów (ang. Structural Health Monitoring - SHM). Niestety większość autorów skupia się na zagadnieniach wykrywania uszkodzeń i innymi czynnościami związanymi z diagnostyką. Tymczasem, klasyczny układ monitoringu powinien, z definicji, posiadać poza modułem diagnostycznym również moduł odpowiedzialny za monitorowanie obciążeń. Te obciążenia mogą być mierzone, lecz taniej i łatwiej jest identyfikować je na podstawie pomiaru odpowiedzi obiektu. Często jest to jedyna praktyczna możliwość ich monitorowania. Artykuł przedstawia próbę zastosowania filtru przestrzennego opartego na eksploatacyjnych formach drgań (ang. Operational Deflection Shapes - ODS) do identyfikacji wymuszeń. Pokazana będzie idea filtru przestrzennego wraz z metodą jego aplikacji do rekonstrukcji siły. Zawarta będzie także weryfikacja symulacyjna i porównanie z klasycznym filtrem modalnym.
PL
Artykuł ten dokonuje przeglądu istniejących technik filtracji sekwencji wideo, ze szczególnym uwzględnieniem możliwości ich zastosowania do aplikacji czasu rzeczywistego. Zaproponowano też rozwiązanie wykorzystujące detekcję ruchu w kolejnych klatkach ograniczającą efekt smużenia, połączone z zastosowaniem przestrzennych wersji wektorowej mediany oraz filtra FDPA. Szczególnie efektywne jest zastosowanie proponowanych rozwiązań w połączeniu z poprawą kontrastu do sekwencji wykonywanych przy słabym oświetleniu.
EN
An overview of real-time video filtering techniques was presented in this paper. The new approach is based on temporal mean combined with movement detection and spatial filtering was presented. Presented technique provides excellent noise suppression ability with low computational complexity.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.