Ograniczanie wyników
Czasopisma help
Autorzy help
Lata help
Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 30

Liczba wyników na stronie
first rewind previous Strona / 2 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  sondowanie statyczne
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 2 next fast forward last
PL
W artykule przedstawiono wyniki analizy osiadań podłoża budynku głównego bloku energetycznego o mocy 910 MW w Elektrowni Jaworzno III – Elektrownia II. Analiza bazowała na wynikach wierceń, sondowań dynamicznych, sondowań statycznych CPTU i testach DMT. Obliczenia osiadań przeprowadzono metodą analizy statycznej.
EN
The paper presents the results of static analysis of subsoil settlements the main building of 910 MW power unit in Power plant Jaworzno III – Power plant II. The analysis based on results of drilling, dynamic penetration tests, static penetration CPTU and DMT tests. The calculation of settlements were performed using static method.
3
Content available remote Błędy w rozpoznaniu podłoża gruntowego
EN
The paper presents the results of geological investigations of ice-dammed clays from Wierzbica near Serock (Central Poland). Physical and mechanical properties of varved clays were determined mainly during in situ tests. Different available equipment and methods were used for determining current geological and engineering conditions. Static tests CPT(U), dilatometer tests (DMT) and pressure meter tests (PBP) were performed and compared. Deformation modulus E, shear strength cu, yield pressure σy, limit pressure pl, and other parameters were evaluated. The selected methods were compared with respect to differences between the obtained results. With the use of statistical methods, the variability of ice-dammed lake sediments is presented. For this reason, the parameters should be carefully estimated. The geological environment is still diverse and difficult to apprehend. Histograms of collected data illustrate distribution of mechanical properties of varved clays from Wierzbica.
PL
Praca jest kontynuacją badań Autorów nad modelem krzywej Meyera Kowalowa[8] opisującej zachowanie pala pod obciążeniem. W artykule podano propozycję opisu parametrów modelu krzywej MK w nawiązaniu do wyników sondowania CPT. W części obliczeniowej przedstawiono analizę zachowania pali przemieszczeniowych SDP pod próbnym obciążeniem statycznym, posiłkując się badaniami literaturowymi i własnymi. Autorzy proponują metodę określania nośności pobocznicy pala, którego podstawa jest zagłębiona w zagęszczone grunty niespoiste na podstawie wyników badań sondowania statycznego CPT, jednocześnie porównując wyniki otrzymane w analizie do wyników badań literaturowych i własnych. Zróżnicowane metody określania nośności podstawy pala na podstawie sondowania CPT prowadzą do otrzymania szeregu krzywych obrazujących nośność pobocznicy. Cechą wspólną tych krzywych jest występowanie maksimum dla oporu pobocznicy.
EN
Paper presents the proposal of modelling the shaft of pile resistance, by using of Meyer Kowalow method. Meyer Kowalow method is known as a method of static pile load test interpretation. It was well presented in literature by Meyer and Kowalow[8], Meyer and Szmechel (2011), Meyer (2013), Szmechel[18]. Meyer Kowalow method is mainly used to predict ultimate bearing of the pile. During the analysis of pile load settlement curve we get also additional coefficients like C, and ĸ. It’s probable that those additional coefficients are directly bounded with soil properties. According to this, parts of MK coefficients are taken directly from cone penetration test results as a proposal. Authors want to use of MK method to predict changes of shaft of the pile resistance, in case when the pile base is recessed in very dense noncohesive ground. For this case it is possible to assume that pile works separately in two different cases. In case one only base of the pile takes part of the pile resistance and when the case two is realized both shaft and base works together. Paper presents six different cases of pile behavior under static pile load test, their settlement and shaft base-relation resistance analysis for practical cases of pile foundation.
PL
Artykuł przedstawia problem występujący na terenach związanych przed II wojną światową i krótko po niej z podziemnym górnictwem węgla brunatnego. Na ziemi lubuskiej na przestrzeni ok. 150 lat funkcjonowało kilkaset podziemnych kopalń węgla. Obecnie część terenów pokopalnianych podlega zagospodarowaniu, np. dla celów zabudowy mieszkaniowej. Do tej pory brak jest wypracowanej procedury badań geologicznych i geofizycznych, jakie powinny mieć zastosowanie na tym terenie. Zaprezentowano konkretne przykłady badań, w tym geofizycznych, jakie zostały przeprowadzone w celu określenia przydatności terenów pogórniczych na cele budowlane w Zielonej Górze. Podano także krótki opis sposobu i zarys historii eksploatacji węgla brunatnego.
EN
On the background of the former method of lignite extraction (already not used in Poland) and short history of lignite mining, the paper presents the problem of surface deformation connected with former underground lignite mining on Ziemia Lubuska (West Poland). Currently part of this area is going to be a builtup area. The paper presents one example of complex geological or geophysical investigation executed in Zielona Góra to determine possibility of development of the area. 7 boreholes to the depth of 10 m, 3 boreholes of 20 m, dynamic tests and static tests (CPT) to the depth of 13–21 m were done. CPT tests and boreholes didn’t show any zone of lower soil density, which could be correlated with loosen soil above former lignite exploitation. Standard tests were supplemented with seismic investigation by MASW 2D method. 3 seismic profiles with length of 115 m were done. A seismic boundary of zone of lower density soil were marked out. This zone can be correlated with area of discontinuous surface deformation. Geophysical investigations didn’t enable to discover location of former shafts. Performed investigations allow to determine the zone of former mining and to design residential building outside this area.
EN
In this paper were verify the possibilities of use the ground penetrating radar method to defining the range of depression cone during pumping test the first free aquifer. On the experimental area there were: pumping well with observation weels, geotechnical weels and cone penetration tests. This made possible the credible interpretation of the results with GPR investigations. GPR measurements were executed before pumping and after stabilizing the depression. On the echograms there were clearly appeared the free aquifer before and during of the pumping. On the basis of geophisical investigations it was successful to interpret the position of free aquifer and the range of depression cone.
8
Content available remote Panaceum na rozpoznanie podłoża gruntowego : CPTM czy CPTU?
PL
Panaceum to mityczny (legendarny) środek leczniczy potrafiący uleczyć każdą chorobę. Czy pomiary sondami statycznymi CPTM i CPTU są w stanie pomóc w każdym problemie geoinżyniera?
EN
The panacea is a mythical (legendary) therapeutic agent capable of curing any disease. Are measurements with CPTU and CPTM static probes a cure to all geoengineering problems? CPT static tests have been used in geoengineering for nearly 50 years. With electronics and computer-aided technologies, the measurements and recordings are more accurate and it is easier to interpret the results. CPTM and CPTU tests have became common field tests, which are used primarily to study the subgrade. However, both techniques should not be used interchangeably!
PL
Wraz z intensywną rozbudową infrastruktury drogowej w Polsce realizowanych jest wiele projektów wzmocnienia słabonośnego podłoża gruntowego w celu bezpiecznego posadowienia nasypów drogowych. Realizacja tych projektów wymaga doskonałego rozpoznania warunków gruntowo-wodnych przed, podczas i po wykonaniu wzmocnienia/wymiany podłoża gruntowego. Jedną z najbardziej przydatnych technik badawczych są sondowania statyczne CPT i CPTU. Autorzy, bazując na licznych, zrealizowanych już projektach drogowych, zebrali doświadczenia i dane dotyczące wykonanych sondowań statycznych. W artykule przedstawiono przykłady zastosowania sondowań statycznych wraz z propozycją metody interpretacji wyników badań.
EN
In the past decade numerous motorway projects have been initiated and many of them are in the process of construction in Poland. The newly designed motorways are often crossing areas with large and deep deposits of oragnic soils. Based on experiance gained at the Al, A2 and S3 motorway project, authors of this paper, are presenting how CPT/CPTU soundings have been appied on a large scale in the soil improvement projects. This paper decribes phases of soil improvement execution with particular interest in the application of sounding techniques. The following phases are discussed: geotechnicai investigations, improvement design, post executrion control/ soundings, and CPTU soundings at the settlement monitoring stage.
10
Content available remote Problemy geotechniczne podczas budowy dróg
PL
Sondowanie statyczne (CPT/CPTU) jest co raz częściej stosowane w Polsce do rozpoznania podłoża pod obiekty budowlane, gdyż pozwala na bezpośrednie wykorzystanie wyników do projektowania fundamentów, w szczególności palowych. Zastosowanie sondy statycznej staje się problematyczne, gdy w podłożu zalegają grunty grubo- i bardzo gruboziarniste – w takich sytuacjach można zastosować sondowanie dynamiczne (DPH lub DPSH). Artykuł przedstawia analizę wyników badań uzyskanych w węzłach badawczych, obejmujących sondowanie CPT, sondowanie DPH oraz otwór wiertniczy. Prezentowane są uzyskane zależności pomiędzy statycznym (qc), a dynamicznym (qd) oporem wprowadzania stożka sondy. Uzyskane korelacje porównano z wynikami podobnych prac przeprowadzonych na Węgrzech oraz na Litwie.
EN
Static cone penetration testing (CPT/CPTU) is increasingly being used in Poland to examine the subsoil. The results of this test may be used directly in foundation design, especially of pile foundations. The use of a static test becomes problematic when coarse and very coarse soils are found in the subsoil. In such cases dynamic probings (DPH or DPSH) can be performed. This paper presents an analysis of the results of field tests conducted in the test nodes, which included CPT, DPH and a borehole. Correlations between static (qc) and dynamic (qd) cone resistances are analyzed in comparison to the results of similar studies performed in Hungary and Lithuania.
EN
This article presents results of studies conducted in a calibration chamber and concerning the effect of stiffness of a layer of sand and silty clay on recorded values of cone resistance and sleeve friction in the process of static penetration. Results of analyses made it possible to determine the qualitative and quantitative effects of stiffness in both layers on the fluctuations in penetration characteristics. Analyses also showed that in the evaluation of soil layer stiffness the thickness of the layer with a lower stiffness needs to be taken into consideration. This article presents an analytical proposal for a correction of cone resistance in the layer of lower stiffness. This article contains examples for the incorporation of diverse layer stiffness on the evaluation on undrained shear strength, constrained deformation modulus and liquidity index of clay layer.
EN
Soil field testing performed with the static method of CPT/CPTU is increasingly being used in Poland to examine the ground for the purposes of foundation design. The results of this test may be used directly in the calculations of foundation piles, but also of spread foundations. The use of a static test becomes problematic when coarse soils (sandy gravels, gravels) are found in the subsoil. In these situations a dynamic probing may be performed to supplement the results of CPT in the soil strata where the CPT examination is impossible. This requires the development of appropriate correlation between the soil parameters obtained in static (qc) and dynamic tests (qd). This paper presents an analysis of the results of field tests conducted in Kraków, Poland. Results were obtained in the test nodes, which included: cone penetration test (CPT), dynamic probing (DPH) and a borehole. The derived correlations were compared with the results of similar studies performed in Hungary and Lithuania.
PL
Sondowanie statyczne metodą CPT/CPTU jest co raz częściej stosowane w Polsce do rozpoznania podłoża pod obiekty budowlane. Wyniki tego badania można wykorzystać w bezpośredni sposób przede wszystkim do projektowania pali fundamentowych, ale także fundamentów bezpośrednich. Zastosowanie sondy statycznej staje się problematyczne, gdy w podłożu zalegają grunty gruboziarniste (pospółki, żwiry). W takich sytuacjach można zastosować sondę dynamiczną i uzupełnienie wyniki badania CPT dla warstw, gdzie przeprowadzenie badania CPT jest niemożliwe. Wymaga to jednak opracowania odpowiednich korelacji pomiędzy parametrami qc i qd. Artykuł przedstawia analizę wyników badań przeprowadzonych w węzłach badawczych, obejmujących sondowanie statyczne CPT, sondowanie dynamiczne DPH oraz otwór wiertniczy. Prezentowane są uzyskane zależności pomiędzy oporem statycznym qc, a dynamicznym qd. Uzyskane korelacje porównano z wynikami podobnych prac przeprowadzonych na Węgrzech oraz na Litwie.
PL
W pracy przedstawiono proces projektowania geotechnicznego związany z realizacją jednej z elektrowni wiatrowych należących do Pyrzyckiej Farmy Wiatrowej zlokalizowanej w województwie zachodniopomorskim. Podano sposób wykorzystania wyników sondowania statycznego CPTU w celu zaprojektowania posadowienia elektrowni wiatrowej. Wykorzystano je zarówno do ustalenia wyprowadzonych wartości parametrów geotechnicznych jak i do oceny nośności podłoża oraz osiadań fundamentu. Na podstawie przeprowadzonych obliczeń porównawczych z powszechnie stosowaną metodą projektowania posadowień fundamentów stwierdzono, iż zastosowanie metodyki badań oraz projektowania na podstawie badań CPTU pozwala w szybki i ekonomiczny sposób wyznaczyć model podłoża gruntowego oraz z dużym zapasem bezpieczeństwa ocenić nośność i osiadania podłoża fundamentu turbiny wiatrowej.
EN
This paper presents the geotechnical designing method of the wind turbine located in the Pyrzyce Wind Farm. The guidelines for the application of the investigation results obtained from the cone penetration testing for designing of those constructions were presented. The CPT results were used both to determine of geotechnical parameters of soils as well as to the estimation of the subsoil bearing capacity and the value of the foundation settlements. The comparative calculations based on the Polish Standard were performed and the usability, economical advantage and the high safety margin in case of the wind turbine foundation designing were demonstrated.
EN
Examples of geoengineering methods (static and dynamic probings) that can be applied to analyses of geological environments are presented. The potential is shown by the results of the determination of the values of the soil-density index (ID), the soil-behaviour index (Ic), the constrained modulus (M), the overconsolidation ratio (OCR) and their vertical changes. The values obtained for ID and Ic facilitate the determination of layers with a specific character. This is demonstrated for several aeolian and glacial deposits in Poland. The application of static probings to the analyses of changes in OCR and M made it possible to identify several depositional phases and the effect of postdepositional processes. Usages of the probings can significantly contribute to the interpretation of palaeo-environments (e.g. in the context of geostatistical models), but the results obtained should be handled cautiously.
PL
Przedstawiono propozycję analizy pracy pali prefabrykowanych wbijanych na podstawie sondowań statycznych CPT. Jako kryterium osiągnięcia nośności granicznej przyjęto osiadanie głowicy wynoszące 10% wymiaru boku pala. Podano wartości oporów jednostkowych pobocznicy i stopy pala przy pośrednich wartościach osiadań, co umożliwia prowadzenie symulacji krzywej obciążenie - osiadanie pala. Przeprowadzono analizę porównawczą 37 pali o przekroju kwadratowym 0,3xO,3 i 0,4x0,4 m, wbijanych w piaski i grunty spoiste. Stwierdzono dobrą zgodność między nośnością obliczoną i pomierzoną oraz zadowalającą zgodność osiadań obliczonych i pomierzonych przy obciążeniu odpowiadającym 40% granicznej nośności pala.
EN
The paper presents a capacity of driven precast piles prediction method based on the results of CPT tests. The pile settlement equal to 10% of pile diameter is assumed as a criteria of pile capacity to be reached. The method gives a unit skin friction and a unit base resistance for ultimate and intermediate pile settlements, which allow to simulate the load-settlement curve. The comparative analysis of 37 square 0.3xO.3 m and O.4xO.4 m piles in clays and sands was carried out. The comparison shows a good agreement between the predicted and actual capacities and a satisfactory agreement between the predicted and actual slope of the load-settlement curve in the range up to 40% of the ultimate pile capacity.
17
Content available remote Wykorzystanie sondowań statycznych do obliczania nośności i osiadań pali
PL
Stosowanie fundamentów głębokich, w tym pali, zawsze powinno być związane z rozpoznaniem podłoża gruntowego na znaczne głębokości, w tym kilka metrów poniżej podstawy elementu przekazującego obciążenie na grunt. Obecnie, słusznie, oprócz wierceń coraz szerzej stosowane są różnego rodzaju pomiary in situ. Powszechnie stosuje się sondy statyczne CPT (w różnych odmianach), sondy dynamiczne SD, SPT, presjometry PMT, dylatometry DMT.
PL
Przedstawiono przykład zastosowania pomiaru prędkości fal akustycznych w terenie do wyznaczania modułu odkształcenia postaciowego G0 w prekonsolidowanych gruntach spoistych. Opisano metodykę oraz wyniki badań terenowych, które wskazują na potrzebę uwiarygodnienia metod pomiaru in situ badaniami laboratoryjnymi.
EN
The paper presents example of in situ measurements of seismic wave velocity for determination of shear modulus G0 in overconsolidated cohesive soils. In situ measurements of seismic wave velocity performed at Stegny test site were described. An analysis of seismic cone penetration tests results indicates that existing formulae for G0 evaluation play regional role and have to be applied for each kind of soil and subsoil stress history.
PL
Referat przedstawia badania i obserwacje związane z wykonywaniem badań odbiorczych podłoża gruntowego wzmocnionego kolumnami wymiany dynamicznej. Opisuje technologię formowania kolumn, obliczenia projektowe, sposoby odbioru kolumn wraz z opisem różnych metod badań. Przedstawiono różnorodną metodykę badań odbiorczych tak, aby sprawdzanie wykonanego wzmocnienia nie ograniczało się jedynie do ustalenia geometrii kolumn, ale aby była możliwa również pełną ocena jakości ich wykonania - sprawdzenie kryteriów odbiorczych (zagęszczenie, moduł). Dobór odpowiedniej metody w zależności od warunków oraz poprawny sposób jej wykonania (po czasie niezbędnym do rozproszenia nadwyżek ciśnienia porowego) gwarantuje prawidłowe prowadzenie nadzoru geotechnicznego na budowie.
EN
Research and observations made during soil improvement are described. Technology of column formation, criteria of acceptance, and calculations compared with the settlement of the embankment, are presented. Rebourning effect at bearing layers at the column bottom and a distinct pore overpressure migration caused by pounder energy where detected at the acceptance tests.
20
Content available remote Wykorzystanie metody statycznego sondowania do identyfikacji rodzaju gruntów
PL
W pracy przedstawiono wyniki prac przeprowadzonych w celu adaptacji systemu klasyfikacyjnego Robertsona (1990) w odniesieniu do gruntów występujących na terenie Polski. Na podstawie badań wykazano, że konieczne jest wprowadzenie korekt zakresów przypisanych poszczególnym rodzajom gruntu do obu diagramów, przy czym ustalono ich zakres dla diagramu głównego (Qt - Fr) i określono zakres badań w celu modyfikacji diagramu pomocniczego (Qt - Bq).
EN
The paper presents adaptation of 1990 Robertson classification charts to Polish soils. Execution of field and laboratory tests and use of statistical methods allowed to modify the main chart so it reflects Polish conditions and classifications. Further works must be carried out to adjust the Bq - Qt chart because of its current poor capacity.
first rewind previous Strona / 2 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.