Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  solids concentration
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
One of the main parameters influencing heat transfer in a circulating fluidized bed boiler is the distribution of the bed's solids concentration within the contour of the boiler’s combustion chamber. This paper contains an analysis of the impact of the solids concentration in a fluidized bed on the vertical temperature profile in the combustion chamber of a SC-OTU CFB boiler. Investigations were conducted at different loads of nominal generator power: 100%, 80%, 60% and 40%. Solids concentration was determined through pressure sensor measurements. Pressure measurements were taken at 11 measuring ports situated on the front wall of the combustion chamber. The vertical temperature profile was produced on the basis of temperature measurements from various furnace elevations. The combustion process was carried out at various primary to secondary air ratios with a constant excess air coefficient.
EN
One of the main parameters influenced on the heat transfer in the circulating fluidized bed boiler is distribution of bed’s solids concentration within the contour of boiler’s combustion chamber. In this paper analysis of influence of fluidized bed’s solids concentration on the vertical temperature profile in the combustion chamber of SC-OTU CFB boiler is carried out. Investigations were conducted with different loads of generator’s nominal power i.e. 100%, 80%, 60% and 40%. Solids concentration was specified on the base of pressure measurement within boiler’s combustion chamber using pressure sensors. Pressure measurements were carried out in 11 measuring ports situated on the front wall of combustion chamber. Vertical temperature profile was achieved on the base of temperature measurements at different furnace elevations. Combustion process was carried out with different primary to secondary air ratio and constant excess air coefficient.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.