1
Content available remote Ocena jakości wód osadowych wybranymi parametrami
EN
The sludge liquor, generated during thickening, biological stabilization and dewatering of sludge is usually returned to the beginning of the wastewater treatment system without any purifying. It causes problems with stable and correctly functioning of WWTP. Sludge liquors are characterized by a high variability in quantitative and qualitative and large loads of pollutants, which are not under control of exploiters. The characteristic of supernatants generated in WWTP in Koszalin and concentration range of pollution was presented. The results allowed to determine the correlation between selected parameters. Their analysis showed that it is possible to determine the size of the pollutant load of recycled sludge liquor to wastewater treatment plant (compounds of carbon and nitrogen) using a simple measurement of conductivity.
PL
Wody osadowe, powstające podczas zagęszczania, biologicznej stabilizacji i odwadniania osadów, ściekowych zawracane są zwykle do głównego ciągu oczyszczania ścieków bez ich oczyszczania, co może generować problemy ze stabilnością i wymaganą do osiągnięcia efektywnością pracy oczyszczalni ścieków komunalnych. Wody osadowe charakteryzują się znaczną zmiennością ilościowo-jakościową oraz dużymi ładunkami zanieczyszczeń, które nie podlegają żadnej kontroli eksploatatorów. W artykule przedstawiono charakterystykę wód osadowych z oczyszczalni ścieków w Koszalinie. Na podstawie uzyskanych korelacji wybranych parametrów wykazano, że jest możliwe określenie wielkości ładunku zanieczyszczeń recyrkulowanych z wodami osadowymi do oczyszczalni ścieków (związki węgla i azotu) za pomocą prostego pomiaru przewodności właściwej.
PL
W artykule przedstawiono problem ładunków powrotnych azotu i fosforu w wodach z odwadniania przefermentowanych osadów ściekowych w oczyszczalniach z podwyższonym usuwaniem biogenów. Na podstawie analiz z lat 2008 – 2013 wykonywanych w oczyszczalniach ścieków Płaszów i Kujawy w Krakowie określono średnie roczne ładunki azotu i fosforu w odciekach. W oczyszczalni Płaszów ładunki powrotne azotu nie przekraczały 10,1%, w przypadku fosforu wyniosły max. 25% w stosunku do ładunku w ściekach dopływających do oczyszczalni. W oczyszczalni Kujawy stwierdzono znacznie wyższe wartości, które wynosiły: dla azotu max. 20,1% i fosforu max. 33% przy utrzymującej się tendencji wzrostowej. Przedstawiono zastosowane w oczyszczalni Płaszów rozwiązanie skutecznie ograniczające ładunek powrotny fosforu, polegające na kondycjonowaniu osadu przefermentowanego z jednoczesnym wiązaniem fosforu z fazy ciekłej za pomocą koagulantu żelazowego. Wskazano również kierunki działań mających na celu ograniczenie wpływu ładunków powrotnych azotu i fosforu na proces oczyszczania ścieków w oczyszczalni Kujawy.
EN
This paper is focused on problem of nitrogen and phosphorus load in the digested sludge dewatering liquor (centrate). Rise of N and P load for five years in Plaszow and Kujawy Wastewater Treatment Plant was evaluated. In Plaszow plant it was max. 10,1% for N and max. 25% (of total in flow load) for P. In Kujawy plant it was higher: max. 20,1% for N and 33% for P. Sludge conditioning with Fe+3 was applied to reduce phosphorus load from centrate in Plaszow Plant. Directions for reduction of N and P in centrate in Kujawy Plant were presented.
EN
This paper focuses on increasing quantities of digestate which is a final product of anaerobic digestion in biogas stations used as alternative sources of energy or as fermenting facilities which can reduce the quantities of biodegradable wastes on landfills. Digestate is a stabilised material produced by anaerobic digestion in a biogas station in addition to the main product - biogas. Potential use of digestate is limited due to its rather specific physical properties. In particular, individual components in digestate are extremely difficult to separate and its chemical or microbiological composition is special. The quality of digestate is affected mostly by the type of biomass. This paper presents current approaches to digestate and digestate management. It also includes taking and analysing digestate samples, processing of the samples in laboratory centrifuges and assessing the properties of digestate and separation products, i.e. the sludge liquor and separatum.
PL
Niniejszy referat koncentruje się na zwiększaniu ilości produktu pofermentacyjnego, który jest finalnym produktem fermentacji beztlenowej w stacjach biogazu używanych jako alternatywne źródło energii lub jako zakłady fermentacyjne, które mogą redukować ilości odpadów biodegradowalnych na składowiskach. Produkt pofermentacyjny jest materiałem powstałym w fermentacji beztlenowej w stacji biogazu będący dodatkiem do produktu głównego – biogazu. Potencjalne zastosowanie tego produktu jest ograniczone ze względu na jego specyficzne właściwości fizyczne. W szczególności jego pojedyncze składniki są niezwykle trudne do oddzielenia a jego skład chemiczny bądź mikrobiologiczny jest unikalny. Na jakość produktu pofermentacyjnego wpływa głównie rodzaj biomasy z której powstaje. Referat przedstawia aktualne podejście do gospodarki produktem pofermentacyjnym. Zawiera również sposób pobierania i analizy produktu pofermentacyjnego, przetwarzanie próbek w laboratoryjnych wirówkach oraz ocenę właściwości i oddzielenie produktów, tj. cieczy osadowej i substancji oddzielonej.
4
Content available remote Generation and management of wastewater from ground water treatment
EN
Use of various wastes containing iron or aluminium in wastewater treatment can be considered as an alternative method to expensive and commercial reagents. These wastes can be recycled thanks to this method, which is important from an environmental point of view. Washings generated during ground water treatment are rather useless but they are one of waste iron sources. The article demonstrates a description of two ground water treatment plants supplying the city of Koszalin with drinking water. On the basis ofdata from the last four years, a balance of the annual amount ofiron sludge formed as a result of backwashing filter beds in both plants was performed. The amount of waste iron exceeds 10 Mg Fe-year1. Research on waste iron usage to remove oithophosphates from a model solution and real sludge liquor from sludge digestion showed that iron sludge from washings can be efficiently used in wastewater treatment technology.
PL
Wykorzystywanie w procesach oczyszczania ścieków różnorodnych odpadów zawierających żelazo lub glin może stanowić alternatywę dla drogich reagentów komercyjnych oraz sposób na ich skuteczne zagospodarowanie, istotne z punktu widzenia ochrony środowiska. Jednym ze źródeł żelaza odpadowego są popłuczyny powstające podczas uzdatniania wody podziemnej, które nie są w praktyce wykorzystywane. W artykule przedstawiono charakterystykę dwóch stacji uzdatniania wody podziemnej zaopatrujących miasto Koszalin. Na podstawie danych z ostatnich 4 lat przeprowadzono bilans rocznej ilości żelaza odpadowego powstającego z płukania złóż filtracyjnych na obu stacjach, których ilość przekracza 10 Mg-rok^-1. Badania nad zastosowaniem osadów z popłuczyn do usuwania ortofosforanów z roztworu modelowego oraz z rzeczywistych wód osado wych po procesie fermentacji osadów ściekowych wykazały możliwość skutecznego wykorzystania żelaza odpadowego w technologii oczyszczania ścieków.