This paper presents the mathematical model of a single-phase multi-winding core type transformer taking into account magnetic hysteresis phenomenon based on the feedback Preisach model (FPM). The set of loop differential equations was developed for a K-th winding transformer model where the flux linkages of each winding includes flux Φ common to all windings as a function of magneto motive force Θ of all windings. The first purpose of this paper is to implement a hysteresis nonlinearity involved in the Φ(Θ) function which also accounts residual magnetic flux. The second purpose of this paper is experimental validation of the developed transformer model in a capacitor discharge test and several different values of residual magnetic flux.
PL
W referacie przedstawiono wyniki badań eksperymentalnych i symulacyjnych wpływu indukcji remanencji w rdzeniu transformatora jednofazowego na jego stan przejściowy przy jego pracy jałowej. Badany obiekt jest układem transformatorowym o dwóch uzwojeniach nawiniętych na zwijanym z blachy anizotropowej rdzeniu w kształcie toroidu. Doświadczenia eksperymentalne polegały na rozładowywaniu kondensatora przez uzwojenie strony pierwotnej przy kilku różnych wartościach początkowego magnetycznego strumienia szczątkowego w rdzeniu. Zastosowanie kondensatora jako źródła energii zapewniło stosunkowo dużą powtarzalność stanów przejściowych niezależną od chwili włączenia i zjawisk na stykach łącznika. W referacie przedstawiono także model obwodowy badanego układu transformatorowego z uwzględnieniem histerezy magnetycznej. Model ten jest w stanie symulować stany przejściowe i ustalone badanego układu przy uwzględnieniu wartości i znaku początkowego strumienia szczątkowego w rdzeniu. Do symulacji zjawiska histerezy zaimplementowano model histerezy Preisacha ze sprzężeniem zwrotnym. Uzyskano stosunkowo dobrą zgodność pomiędzy wynikami symulacji i eksperymentu. Wyprowadzone wnioski wskazują na istotny wpływ indukcji remanencji na wartość prądu udarowego. Wykazano także przydatność zastosowanej metodyki modelowania obwodowych układów transformatorowych do symulacji stanów przejściowych z uwzględnieniem histerezy magnetycznej oraz strumienia szczątkowego.
EN
This paper presents the results of the experimental and simulation investigation concerning the influence of remanence in the core of a single-phase transformer at the no-load transient state. The tested transformer is a special laboratory transformer system comprising two windings and the toroidal core made of the anisotropic ribbon of steel. Experimental studies consisted of the discharge of the capacitor through the primary winding at several different values of the residual magnetic flux. The use of a capacitor as a Power source has provided a relatively high repeatability of the measured transient states independent of the moment of switching and the phenomena at the terminals of the connector. The paper presents a model of the transformer test system taking into account the magnetic hysteresis phenomenon. The model was used to simulate the transient and steady state of the test system taking into account the value and the sign of the remanence in the toroidal core. The Preisacha model with feedback was used to magnetic hysteresis modelling. The results of the simulation investigation were found in very fair agreement with the experimental results. It was concluded that the induction of remanence has a significant impact on the value of the surze current. This indicates the usefulness of the applied circuit modeling methodology for the simulation of the transformer systems transient state taking into account the magnetic hysteresis and the remanence.
EN
This paper presents the method for determination of leakage inductances of single-phase and multi-winding transformer. The matrix of leakage inductances takes into account leakage self and also leakage mutual magnetic couplings. It is assumed that there is a flux common to all windings and several leakage fluxes referred to a particular winding. The flux linkages of each coil needed for calculation of leakage inductances was computed by FEM commercial software Opera 3D. The values of leakage inductances matrix have been calculated for special reduced scale traction, 19.3 kVA transformer. This is core type construction transformer with eight windings.
PL
W referacie przedstawiono sposób wyznaczania indukcyjności rozproszenia cewek elementarnych transformatora jednofazowego na podstawie obliczeń elektromagnetycznych. Wyznaczono indukcyjności rozproszenia własne i wzajemne. Pojęcie indukcyjności własnej ujmuje strumień rozproszenia sprzęgający się z cewkę wzbudzany przez prąd tej cewki. Pojęcie indukcyjności wzajemnej obejmuje strumień rozproszenia sprzęgający się z cewkę wzbudzany przez prądy innych cewek. Wartości indukcyjności rozproszeń są ważnym parametrem obwodowym transformatora mającym istotny wpływ na stany przejściowe i ustalone. Obliczenia wykonano w odniesieniu do transformatora o mocy 19,3 kVA o konstrukcji rdzeniowej, który zawiera osiem uzwojeń. Rozkład pola magnetycznego wyznaczono na drodze symulacji polowej przy wykorzystaniu programu Opera 3D. Indukcyjności wyznaczono na podstawie analiz strumieni sprzężonych z cewkami w funkcji prądów w poszczególnych cewkach.
4
PL
Przeprowadzono badania modułu i fazy współczynnika napięciowego wybranych transformatorów jednofazowych w zakresie częstotliwości charakterystycznych dla przepięć atmosferycznych, łączeniowych i dorywczych. Stwierdzono, że istotny wpływ na charakterystyki częstotliwościowe tego współczynnika mają parametry konstrukcyjne i stan pracy transformatorów. Przebiegi napięcia o wysokich częstotliwościach są silniej tłumione przez transformatory, niż przebiegi o średnich i niskich częstotliwościach.
EN
Investigations of module and phase of voltage ratio of selected single-phase transformers were conducted in frequency range characteristic for lightning, switching and temporary overvoltages. It was found that construction parameters and operating conditions of the transformers have essential influence on their frequency characteristics. High frequency voltage functions are more strongly suppressed by the transformers than mean and low frequency functions.