Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  single-phase inverter
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In this paper, a deadbeat control technique for single-phase inverters used in UPS applications is presented. For the suggested control approach to maintain sinusoidal output voltage for high dynamic performance even with load fluctuations, measurements of capacitor current and output voltage are necessary. By reducing the error between the output voltage and the voltage reference without adding more current sensors, the deadbeat controller improves the performance of the proposed controller. It also reduces load voltage distortion and restores the system state in the event of an external shutdown-loop road interference. We suggest a capacitor current estimation based on the Luenberger observer to address this flaw. PROCESSOR-IN-THE-LOOP The "P.I.L" test method, which can be thought of as an expensive system, enables us to create and evaluate controllers by running built-in C code on the DSP scheduled for the controller during simulated PSIM power phase control. To address this drawback, we propose a capacitor current estimation based on the Luenberger observer.
PL
W artykule przedstawiono algorytm sterowania martwym uderzeniem falowników jednofazowych do zastosowań w systemach zasilania awaryjnego (UPS). Proponowana metoda sterowania wymaga pomiaru prądu kondensatora i napięcia wyjściowego w celu utrzymania sinusoidalnego napięcia wyjściowego w celu uzyskania wysokiej wydajności dynamicznej nawet przy zmianach obciążenia. liczbę czujników prądu, a także eliminuje zniekształcenia napięcia obciążenia i przywraca stan systemu w przypadku zewnętrznej ingerencji w pętlę wyłączania drogowego. Aby rozwiązać ten problem, proponujemy oszacowanie prądu kondensatora na podstawie obserwatora Luenbergera. PROCESOR-W-PĘTLI „P.I.L” to metoda testowa, która pozwala nam tworzyć i oceniać kontrolery poprzez uruchomienie wbudowanego kodu C na DSP zaplanowanym dla kontrolera podczas symulowanej kontroli fazy mocy PSIM, co można uznać za kosztowny system , aby poradzić sobie z tą wadą, proponujemy oszacowanie prądu kondensatora na podstawie obserwatora Luenbergera.
EN
The problem of large speed loss exists in the traditional passing through the electric phase-separation method of trains, which is more prominent when trains pass through an electric phase-separation zone in the uphill section of long ramps and may lead to the trains not passing through the phase-separation zone safely. In order to solve this problem, based on the energy storage type railroad power conditioner, a train uninterrupted phase-separation passing system based on the energy storage type railroad power conditioner is proposed. The energy storage railroad power conditioner can realize the recovery and utilization of regenerative braking energy of the electrified railroad. In the structure of the energy storage railroad power conditioner, the single-phase inverter is led from the middle DC side of the energy storage railroad power conditioner and connected to the neutral line through the LCL filter and the step-up transformer, which constitutes an uninterrupted phase separation passing system. The single-phase inverter is controlled using virtual synchronous generator technology, which allows the single-phase inverter to have external characteristics similar to those of a synchronous generator, providing support for the voltage and frequency in the neutral zone. The power required by the train to pass the electric phase-separation is provided by the power supply arm or the energy storage system, which not only improves the utilization rate of regenerative braking energy but also realizes the uninterrupted phase separation passing of the train through the control of the voltage in the neutral region.
PL
Znanym zagadnieniem w jednofazowych falownikach napięcia jest pobieranie ze źródła napięcia stałego składowej przemiennej o częstotliwości dwukrotnie większej od częstotliwości generowanej przez falownik. Jednym z rozwiązań problemu jest stosowanie dużej baterii kondensatorów elektrolitycznych, lecz lepszym sposobem z punktu widzenia niezawodności i gęstości mocy przekształtnika jest stosowanie aktywnych układów odsprzęgania mocy. W pracy przedstawiono ideę aktywnego odsprzęgania mocy na przykładzie układu podwyższającego napięcie. Następnie zaprezentowano sposób doboru elementów obwodu odprzęgającego oraz przyjętą strategię sterowania. Zaproponowany model zweryfikowano w programie symulacyjnym oraz zaimplementowano w zbudowanym modelu laboratoryjnym falownika. W badaniach laboratoryjnych osiągnięto znaczną redukcję składowej prądu wejściowego o częstotliwości dwukrotnie większej od częstotliwości podstawowej falownika oraz sprawność powyżej 94%.
EN
In single-phase inverters the instantaneous output power contains a DC component and a double line frequency power oscillation. To cope with the issue of inducing a significant current and voltage ripples on the DC side, the most popular approach is to decouple DC and AC sides with a bulky bank of electrolytic capacitors. This method is however reducing the reliability, life-time and power density of a converter. Most recently active power decoupling methods are gaining popularity as an alternative approach to solve this issue. In this paper a film capacitor based active power decoupling method in a boost topology is presented. First of all, the methods of DC active power decoupling, the principle of decoupling in a boost topology and selection of decoupling circuit elements are given. Then, the proposed control strategy is described and verified by the simulation. Finally, a constructed prototype of the single-phase inverter is presented and measurements at 500 W output power are conducted. The obtained results proves the feasibility of the identified approach and also high power efficiency of 94% is achieved.
PL
W pracy przedstawiono praktyczne rozwiązanie techniczne falownika do grzania indukcyjnego, który jest prosty w konstrukcji, niezawodny w działaniu oraz w pełni funkcjonalny. Falownik został przebadany w Laboratorium Badawczym Elektrycznym Politechniki Częstochowskiej, a uzyskane wyniki pomiarów w pełni potwierdziły możliwość adaptacji tego rozwiązania do zastosowań przemysłowych przy zasilaniu z sieci jednofazowej oraz możliwości regulacji mocy we wzbudniku w szerokim zakresie.
EN
The paper presents a practical technical solution for induction heating inverter that is simple in construction, reliable in operation and fully functional. The inverter has been tested in the Electrical Testing Laboratory of Czestochowa University of Technology, and the obtained results fully confirmed the possibility of adaptation of this solution for industrial applications with single-phase power supply and the possibility of regulating the power in a wide range of actuators.
EN
Explored in this paper is the grid impedance effect on the stability of a single-phase grid connected inverter with an LC filter based on an analysis of the inverter output impedance. For a single-phase grid connected inverter, a PI controller is often used to regulate the current injected into the grid. However, the control performance can be influenced when the inverter is connected to a weak grid. Also, the utility grid has background harmonic noise, which can make the injected current distorted. Therefore, analysis of the output impedance of a single-phase grid connected inverter is important for the robustness and stability of the system. By modeling the output impedance of inverter, it can be determined that the proportional gain and integral gain of the controller have an effect on the output impedance. Analytical results show that by adjusting the PI controller parameters, the ability for harmonic reduction and stability of the system can be improved. Simulation and experiments using a 1 kW single-phase grid connected inverter verify the effectiveness of the theoretical analysis.
PL
W artykule omówiono zagadnienia związane z projektowaniem i budową falownika mostkowego wykorzystującego azotkowo-galowe (GaN) tranzystory typu Gate Injection Transistors (GIT). Przedstawione są podstawowe właściwości tych tranzystorów wraz z tematyką dotyczącą ich sterowników bramkowych. Następnie zaprezentowany jest model laboratoryjny falownika o mocy 2kVA pracującego z częstotliwością przełączeń równą 250kHz. Artykuł ilustrowany jest wynikami badań laboratoryjnych.
EN
The paper discuses issues related to design and construction of the H-bridge inverter using Gallium Nitride (GaN) Gate Injection Transistors (GIT). Basic features of the transistors are shown together with gate driver topics. Then, a laboratory model of the 2kVA inverter operating at switching frequency of 250 kHz is presented. The paper is illustrated with experimental results.
7
Content available remote A plug-in direct particle swarm repetitive controller for a single-phase inverter
EN
The paper presents an online particle swarm optimizer (PSO) as an iterative learning controller for the single phase inverter with an output LC filter. The novelty of the solution lies in the fact that the swarm directly stores samples of the control signal. The swarm optimizes, according to a user-defined performance index, in online mode the control signal to reject the repetitive disturbance (the load current drawn, for example, by the diode rectifier). The concept of the direct swarm controller is investigated with the help of numerical simulations.
PL
W artykule opisano regulator rojowy realizujący sterowanie z uczeniem iteracyjnym dla jednofazowego falownika napięcia z wyjściowym filtrem LC. Oryginalność rozwiazania polega na fakcie bezpośredniego przechowywania próbek sygnału sterujacego przez rój cząstek. Rój optymalizuje w trybie on-line sygnał sterujący eliminując wpływ okresowego zakłócenia (prądu obciążenia pobieranego, na przykład, przez prostownik diodowy z filtrem pojemnościowym) na jakość napięcia wyjściowego. Sygnał sterujący jest optymalny z uwagi na zdefiniowany przez użytkownika wskaźnik jakości. Koncepcja bezpośredniego regulatora rojowego została zbadana przy użyciu technik modelowania numerycznego.
8
Content available remote The mathematical model of inverter
EN
The new generation mathematical model of single-phase inverter is proposed. The iron-clad transformer is described by equation of quasi stationary electromagnetic field vector potential. The adapter operation of thyristors is described by logical values which reflect the real physical process. Capacitor is described by ordinary differential equation. The coil resistance is changed for balance resistor. There are shown the results of computer simulation of model device transient processes.
PL
Zapropono model matematyczny nowej generacji jednofazowego inwertora. Transformator jest opisany przez równania potencjału wektorowego kwazi-stacjonarnego pola elektromagnetycznego. Operacje sterowania tyrystorów opisane są przez wielkości logiczne, które odzwierciedlają rzeczywisty proces fizyczny. Kondensator jest opisany przez zwyczajne równania różniczkowe. Przedstawiono rezultaty symulacji komputerowej przebiegów przejściowych.
EN
The paper deals with mathematical model of single-phase bridge inverters which outputs voltage is controlled by a pulse-width notching. The transistors in the inverter circuit are turned on and off so as to produce zero periods of equal length, for unipolar modulation, or negative voltage for bipolar modulation. The D.C. source is being a fixed level of voltage. Suppose the notching frequency to be constant for all frequency of the fundamental squarewaves and to be fixed on 500 Hz. The output inverter’s voltage is expressed by an analytical formula based on Fourier complex series. On the base of output voltage, the waveforms of the output currents are analytically calculated for different inverter’s loads.
10
Content available remote Features of a single-phase Z-source inverter
EN
Recently proposed Z-source inverter, based on typical Voltage Source Inverter (VSI) switches topology and special Z network, is able to boost variable DC voltage to supply AC loads. This feature is very suitable in renewable energy systems (fuel cells, solar stacks) and other applications where in-directional DC/AC step-up conversion is required. In power range up to several kW a single-phase system is preferred. The paper shows features of single-phase Z source inverter on the base of simulation tests and laboratory investigations of the low power laboratory model.
PL
Zaproponowany układ falownika typu Z, bazujący na typowej topologii falownika napięcia i specjalnym obwodzie Z, jest w stanie podnosić wahające się napięcie DC do zasilania odbiorników zmiennoprądowych. Taka właściwość jest szczególnie przydatna w systemach zasilania z odnawialnymi źródłami energii (ogniwa paliwowe, fotowoltaiczne) i innych aplikacjach gdzie wymagane jest jednokierunkowe przekształcanie napięcia DC na AC przy jednoczesnym jego podwyższaniu. W zakresie mocy do kilku kW preferowane są układy jednofazowe, dlatego artykuł przedstawia właściwości jednofazowego falownika typu Z na podstawie badań symulacyjnych i laboratoryjnych modelu małej mocy.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.