EN
As for a single line-to-ground fault in an ungrounded distribution system, the power-frequency current is too low to detect the fault. The transient current is more palpable than that at a power-frequency of 50 or 60 Hz. It is an effective method to estimate the fault using the transient fault current. To analyze and calculate the transient current of single line-to-ground faults, an equivalent circuit is proposed in this paper. This model is based on distributed parameters of power lines. And it contains positive, negative and zero sequence information. The transient equivalent circuit consists of equivalent resistance, equivalent inductance and equivalent capacitance. And the method of calculation the equivalent elements is also submitted. MATLAB simulation results show that the new transient equivalent circuit has higher accuracy and stronger adaptability compared with the traditional one.
EN
When a single line-to-ground fault occurs in the ungrounded distribution system, the steady-state fault current is relatively small for fault analysis and the transient fault current is observable, which can be used for faulted feeder identification and location. The principal frequency component retains most of the characteristics of the transient current. The principal frequency is related to the distance from the fault point to the substation and can be used for fault location. This paper analyzes the sequence network model of a single line-to-ground fault in the distribution network, and gives a method for principal frequency calculation. Depending on the characteristics of the maximum amplitude of the principal frequency component of the faulted feeder, the method of faulted feeder identification is given. Based on the complementary characteristics of the phase angle of the principal frequency component of the fault current and the phase angle at the substation bus, the faulted section location is carried out. MATLAB simulation is used to verify the effectiveness of the faulted feeder identification and location method.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.