Ionizing radiation detection in harsh environment conditions often requires additional signal processing to match the requirements of the commercial data readout systems. The subject of this paper is the design of the high-temperature (HT) signal conditioning module that ensures the applicability of scintillation detectors that utilize photomultiplier tubes (PMT) with moderate sampling rate instrumentation. The design was developed for the operation in HT environments (up to 120°C). In order to achieve the optimal signal shape, the module combines a charge amplifi er and a low-pass fi ltering circuitry. An embedded power supply section makes it a complete, standalone unit requiring a single 12 V supplying line. A comprehensive analysis of the developed device, named “PreAmp Shape”, was conducted in order to prove the intended functionality over the different working conditions.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
Omówiono wybrane rozwiązania techniczne związane z coraz bardziej popularnymi systemami monitorowania i nadzorowania procesu obróbki skrawaniem. Przedstawiono podstawowe czujniki oraz elementy toru pomiarowego odpowiedzialne za kondycjonowanie pozyskiwanych sygnałów. Podano analityczną strategię unikania drgań samowzbudnych. Wskazano dostępne na rynku rozwiązania komercyjnych systemów monitorowania i ich możliwości.
EN
The paper illuminates and discusses selected technical solutions related to increasingly popular systems for monitoring and supervising the machining process. The basic sensors and elements of the measurement path responsible for conditioning the acquired signals are presented. An analytical strategy for self-excited vibrations is given. The solutions of commercial monitoring systems and their capabilities available on the market are indicated.
3
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The paper presents a detailed analysis of the properties of selected single-ended to differential converters based on voltage-feedback operational amplifiers. The key issues discussed in the work are: the identification of the equivalent circuit model, definition of the model parameters, effect of resistor tolerances and operational amplifier’s parameters on circuit accuracy, frequency response analysis, conclusions regarding the possibility of adjustment. The obtained results allow for a simple selection of converters with respect to their DC and AC performance.
PL
Artykuł prezentuje analizę działania wybranych układów symetryzatorów napięcia zrealizowanych w oparciu o napięciowe wzmacniacze operacyjne. W pracy poruszono szereg zagadnień, takich jak identyfikacja modelu układu i jego parametrów, wpływ tolerancji rezystorów i parametrów wzmacniaczy operacyjnych na dokładność przetwarzania, analiza częstotliwościowa, możliwość strojenia. Uzyskane wyniki pozwalają na wybór najkorzystniejszego rozwiązania symetryzatora przy uwzględnieniu jego parametrów stało- i zmiennoprądowych.
The paper presents a review of the known signal conditioning circuits that may be used as a front-end of precision high-resolution successive-approximation register (SAR) analog to digital converters (ADC). The review was created while searching for the optimal signal conditioning circuit to be used with a high-resolution SAR ADC applied in a precise sampler for voltage, power, energy and impedance metrology applications.
5
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule zaprezentowano analizę działania wybranych układów symetryzatorów napięcia. Przeprowadzona analiza stałoprądowa i małosygnałowa pozwoliła na sformułowanie szeregu wniosków, dotyczących takich zagadnień jak wpływ tolerancji użytych rezystorów na dokładność układu, możliwość korekcji wartości wzmocnień, wpływ parametrów wzmacniacza operacyjnego na charakterystyki częstotliwościowe. Porównano również poszczególne układy pod kątem cech istotnych z punktu widzenia możliwości ich praktycznego zastosowania.
EN
The paper presents an analysis of operation of a selected single-ended to differential converters based on operational amplifiers. The performed DC and AC analysis provides insight into a variety of issues including effect of resistor tolerances on circuit accuracy, possibility of the parameters adjustment, impact of operational amplifier parameters on frequency response and comparison of circuits with respect to practical design consideration.
6
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule opisano system do wielokanałowej rejestracji elektrycznej aktywności tkanki nerwowej In Vivo z użyciem matryc mikroelektrod. System został oparty na dedykowanym scalonym układzie kondycjonującym. Przedstawiono specyfikę sygnałów neuronowych, metodę ich rejestracji z wykorzystaniem matryc mikroelektrod, wymagania stawiane systemowi rejestrującemu oraz budowę samego systemu. Szczególną uwagę poświęcono metodom redukcji zakłóceń generowanych przez cyfrową część systemu. Artykuł zawiera również wyniki neurobiologicznych eksperymentów in-vivo zarejestrowane z użyciem opisywanego systemu.
EN
The article describes a system for multi-channel recording of electrical activity of nerve tissue In Vivo by using microelectrode arrays. Specificity of neural signals, the method of registration by using microelectrode arrays, requirements for acquisition system and the system itself are presented. Particular attention is given to methods of reduction of noise generated by the digital part of the system. The article also presents results of in-vivo recording realized by the presented system.
7
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W referacie poruszono ważny problem przydatności sygnałów prądu i napięcia rejestrowanych w sieci elektroenergetycznej przy niedotrzymaniu warunków próbkowania tw. Shannona do identyfikacji impedancji sieci. Szerokopasmowe pobudzenia używane w procesie identyfikacji formalnie wymagają korzystania z profesjonalnych i kosztownych rejestratorów sygnałów wyposażonych w filtry antyaliasingowe. Praktyka pomiarowa zazwyczaj jest inna. Wyniki badań wykazują znaczną przydatność rutynowych rejestracji do wstępnej oceny impedancji sieci.
EN
In the paper the usefulness of directly sampled output signals from industrial voltage/current power signal conditioners for the grid impedance estimation is discussed. As such signals do not fulfill Shannon condition they can be easily gathered in field condition with the use of standard instrumentation, however they are not reliable from the DSP point of view. The presented results confirm that, in spite of that, they can well serve as valuable data for initial estimation of the grid impedance.
Pomiary w układach napędowych, zwłaszcza zawierających energoelektroniczne układy przetwarzania energii, wymagają stosowania coraz doskonalszego sprzętu pomiarowego. Pewna część działających w zakładach przemysłowych układów napędowych zasilana jest z sieci średniego napięcia i zasila silniki średniego napięcia. Ze względu na bezpieczeństwo przy wykonywaniu pomiarów w tych układach, sygnały pomiarowe zarówno prądów jak i napięć pobiera się zwykle z wyjść wbudowanych w układ przekładników prądowych i napięciowych. Urządzenia te są kalibrowane dla częstotliwości napięcia sieci (50 Hz) i w różnym stopniu tłumią wyższe harmoniczne mierzonych wielkości. Ich charakterystyki częstotliwościowe rzadko są znane, dlatego rzetelna ocena dokładności wykonanego pomiaru z reguły nie jest możliwa. Ważnym sygnałem mierzonym w układach napędowych jest prędkość. W układach rzeczywistych dostęp do tego sygnału bywa utrudniony lub niemożliwy. W Instytucie Układów Elektromechanicznych i Elektroniki Przemysłowej Politechniki Opolskiej w ciągu dziesięciu ostatnich lat zdobyto rozległe doświadczenie pomiarowe, zakupiono i wytworzono kilka zestawów, za pomocą których wykonywane są pomiary elektrycznych i mechanicznych wielkości w układach napędowych. W artykule opisano m.in. oryginalne układy kondycjonowania sygnałów do pomiaru napięć w sieciach średniego napięcia i do pomiaru różnych rodzajów sygnałów prędkości obrotowej.
EN
Measurements in electrical drives, especially with electronic systems of power conversion, require still to perfect measurement equipment's state of the art. Some of the industrial active drives are powered from medium voltage network, and also supplies medium voltage engines. For the sake of measurement's safety the measured signals are taken from outputs of voltage and current transformers installed in the system. These facilities are calibrated to network frequency (50 Hz), in different extents suppressing the upper harmonics of the measurement signals, their frequency characteristics are mostly unknown, so the accuracy of measurement results is uncertain. Important measurement signal in electrical drive is its rotational speed. In industrial reality access to this signal is difficult or even impossible. During last ten years in Faculty of Electrical Engineering, Automatic Control and Computer Science in Opole University of Technology a lot of measurement experience was collected as well as a few hardware sets had been build to measure an electrical and mechanical values in drive systems. In the article original solutions of signal conditioning for voltage measurement in medium voltage network were described as well as for different types of rotational speed signals.
W artykule opisano badania pasywnych układów kondycjonowania sygnału z generatora elektromagnetycznego, które zaprojektowano do zasilania tłumika magnetoreologicznego (MR) o ruchu liniowym. Przedstawiono układy kondycjonowania zrealizowane na diodach Schottky'ego oraz przekaźnikach analogowych, stanowisko badawcze oraz wyniki badań. Działanie układów porównano analizując charakterystyki częstotliwościowe i czasowe.
EN
The paper deals with laboratory testing of passive conditioning systems improving the output signal of the electromagnetic generator used for a power linear magnetorheological (MR) damper. The generator, composed of permanent magnets and a coil with foil winding, produces electrical energy according to Faraday's law of electromagnetic induction. This energy is applied to vary the damping characteristics of the MR damper attached to the generator by the input current produced by the device. The objective of the conditioning systems is to improve the voltage signal applied to the control coil of the MR damper. The paper describes briefly the conditioning systems based on Schottky's diodes and analog relays, the experimental setup (the self-powered vibration reduction system based on MR damper for a one-degree-of-freedom object, measurement and control equipment) and the results of experimental tests. The performance of the developed conditioning systems is compared by analyzing the determined frequency and time responses.
10
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
A temporal analysis of electromyographic (EMG) activity has widely been used for non-invasive study of muscle activation patterns. Such an analysis requires robust methods to accurately detect EMG onset. We examined whether data conditioning, supplemented with Teager–Kaiser Energy Operator (TKEO), would improve accuracy of the EMG burst onset detection. EMG signals from vastus lateralis, collected during maximal voluntary contractions, performed by seventeen subjects (8 males, 9 females, mean age of 46 yrs), were analyzed. The error of onset detection using enhanced signal conditioning was significantly lower than that of onset detection performed on signals conditioned without the TKEO (40 š99 ms vs. 229 š356 ms, t-test, p = 0.023). The Pearson correlations revealed that neither accuracy after enhanced conditioning nor accuracy after standard conditioning was significantly related to signal-to-noise ratio (SNR) (r = –0.05, p = 0.8 and r = –0.19, p = 0.46, respectively). It is concluded that conditioning of the EMG signals with TKEO significantly improved the accuracy of the threshold-based onset detection methods, regardless of SNR magnitude.
MAX1452 jest analogowym procesorem do kondycjonowania sygnału z czujników piezorezystancyjnych w tym do kompensacji temperatury. Służą temu celowi 4 przetworniki cyfrowo-analogowe sterowane cyfrowo, które korygują czułość i zero w funkcji temperatury. W sytuacji, gdy błędy temperaturowe są początkowo duże i nieliniowe, to najlepsze rezultaty daje stosowanie dwuetapowej procedury doświadczalniej kompensacji: najpierw kompensacja składowych quasiliniowych błędów, a dalsza poprawa za pomocą tzw. kompensacji schodkowej. Ze względu na szumy pomiarowe celowym jest, aby eksperyment do identyfikacji potrzebnych modeli obejmował pewien nadmiar pomiarów w stosunku do liczby wyznaczanych współczynników. W artykule pokazano przykładowe wyniki kompensacji temperaturowej czujnika ciśnienia o zakresie 100 kPa.
EN
MAX1452 is an analog processor for conditioning of the piezoresistive sensor signal and for the temperature compensation. To this purpose applied four digitally controlled analog to digital converters DAC, which sensitivity and offset are correcting as the function of the temperature. In the situation, when temperature errors are at first big and non-linear therefore applying the two-stage experimental procedure is giving the best results of compensation: in the first stage compensation for linear components of errors, but the more further improvement behind the help of the multislope compensation. On account of measuring noises it is intentional so that identification experiment of the models needed for the compensation contains certain excess of measeruments in relation to the number calculated coefficients. In the article results of the temperature compensation were shown for the pressure sensor with the span of 100 kPa.
12
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
A new type of the four-terminal (4T) bridge circuit unconventionally supplied by current sources connected in parallel to opposite arms, named double current bridge (2J) is presented. It has two different outputs from both diagonals. Three variants of such circuit are proposed. Their output voltages are given as functions of arm resistance increments in absolute and in relative units. Signal conditioning formulas of the two-parameter (2D) measurement of these increments and also of two external variables differently influencing them are discussed in detail. First results of instrumentation designed experimentally using 2J bridge circuits are shortly presented. A summary and prospective applications of 2J bridge circuits in multivariable measurements are given. Literature is included.
PL
Przedstawiono nowy rodzaj czterokońcówkowego (4T) układu mostkowego o niekonwencjonalnym zasilaniu ze źródeł prądowych dołączanych równolegle do jego ramion przeciwległych. Nazwano go mostkiem dwuprądowyrn (2J). Ma on dwa różne wyjścia z obu przekątnych. Zaproponowano trzy warianty rozwiązania tego układu Wyznaczono zależności jego napięć wyjściowych w funkcji przyrostów rezystancji ramion w wartościach bezwzględnych i względnych. Szczegółowo omówiono kondycjonowanie sygnałów przy dwuparametrowych (2D) pomiarach tych przyrostów oraz dwu wielkości zewnętrznych niejednakowo na nie oddziałujących. Omówiono w skrócie kilka pierwszych eksperymentalnych konstrukcji urządzeń pomiarowych z mostkami dwuprądowyrni 2J. Podsumowano dotychczasowe rezultaty i wskazano perspektywiczne obszary zastosowania mostków 2J w pomiarach dwuparametrowych. Zamieszczono bibliografię.
13
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
W artykule przedstawiono problemy przetwarzania sygnałów w systemie elektroenergetycznym oraz omówiono metody przetwarzania o wysokiej dokładności uwzględniające specyfikę tych sygnałów. Omówiono, poparte eksperymentem, właściwości sygnałów prądu i napięcia obserwowanych w systemie i wskazano, jak wpływają one na rozwiązania torów przetwarzania analogowego (kondycjonowanie sygnału) oraz metody i techniki przetwarzania cyfrowego informacji pomiarowej zawartej w spróbkowanym sygnale. Na kilku przykładach (dokładny pomiar bieżącej częstotliwości podstawowej systemu, identyfikacja impedancji systemu w szerokim pasmie częstotliwości, wirtualny system pomiarowy do wykrywania i rejestracji stanów anormalnych) pokazano, jak skuteczne mogą być metody CPS w opisie właściwości systemu elektroenergetycznego. Przedstawiony materiał zorientowany jest na zagadnienia aplikacyjne, bazuje na danych eksperymentalnych, dotyczących opisu rzeczywistych systemów w warunkach ich naturalnej pracy, w obecności zakłóceń i niestacjonarności właściwych dla sygnałów obserwowanych w systemie elektroenergetycznym.
EN
The paper presents the problems and solutions of power system signal processing, focused on high accuracy and high quality of analysis. Specyfic power system signals properties which affect the accuracy are presented. Signal conditionning (analog processing) as well as DSP methods oriented used methods to power signals are discussed. Few examples are given which show how accurate and efficient signal processing can be in standard applications: e.g. accurate fundamental frequency estimation, system impedance measurements. A solution of the computerized system, based on the standard DAQ board, for abnormal power system states observation and registration is presented. The presented discussion is applications oriented and is based on experiments and measurements in real power system with real polluted and nonstationary signals.