Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 1

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  shear wall with openings
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A total of 9 real scale reinforced concrete shear walls were produced, 3 of them being the reference, representing the basement floor of a reinforced concrete building. These 9 shear walls produced, 3 wall are fully filled, 3 of them have window openings and 3 of them have door openings. The RC shear walls were exposed to displacement-controlled reversed cyclic lateral loading. In the experiments that damaged the experimental specimens, loads up to 0.5% story drift ratio for moderate damage and 1.0% story drift ratio for heavy damage were applied. Within the scope of the experimental study, the damage distributions of the tested nine RC shear walls were examined in detail, and the strengthening technique was developed using CFRP strip and CFRP fan-type anchors. The performance of damaged RC shear walls after using the devised repair method was analysed. The study's findings revealed that the repair method created by employing CFRP strips to restore moderately damaged RC shear walls with and without apertures was well enough successful in restoring the shear walls' performance levels.
first rewind previous Strona / 1 next fast forward last