Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  shear reinforcement
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents results of experimental tests carried out on concrete beams reinforced with glass fibre polymer reinforced (GFRP) bars, which have become recently one of the main substitutes for traditional steel reinforcement. GFRP bars were used in this research as the longitudinal and transverse reinforcement. An objective of the study was to investigate the influence of the shear reinforcement ratio on the shear capacity of GFRP reinforced concrete beams in comparison with the corresponding beam without shear reinforcement. Single-span, simply-supported T-section beams reinforced in flexure with 5 GFRP bars of 25 mm diameter were reinforced in shear with closed GFRP stirrups of 8 mm diameter applied in three variable spacings: 250 mm, 200 mm and 120 mm. The analysis of test results, failure modes and shear capacity is discussed in the paper in respect to investigated parameters.
PL
W artykule przedstawiono wyniki badań eksperymentalnych przeprowadzonych na betonowych belkach zbrojonych prętami z włókna szklanego GFRP (Glass Fibre Reinforced Polymer), które w ostatnim czasie stały się jednym z głównych zamienników tradycyjnego zbrojenia stalowego. Celem badań była analiza wpływu stopnia zbrojenia poprzecznego na nośność na ścinanie belek żelbetowych zbrojonych GFRP w porównaniu z belką bez zbrojenia na ścinanie. Zastosowano trzypunktowy schemat obciążenia belek o smukłości ścinania (a/d) równym 3,15 co klasyfikuje belki jako smukłe, bez występowania efektu łukowego podczas ścinania. Analizie poddano jednoprzęsłowe belki o przekroju teowym (beff = 650 mm, bw = 250 mm, hf = 80 mm, htot = 400 mm) o rozpiętości w osiach podpór 1800 mm. Obciążenie skupione przyłożono w odległości 1050 mm od podpory. Zbrojenie podłużne składało się z 5 prętów GFRP o średnicy 25 mm (stopień zbrojenia poprzecznego ρl = 2,91%). Zbrojenie poprzeczne zastosowano w formie zamkniętych strzemion GFRP o średnicy 8 mm w trzech różnych rozstawach: sf = 250 mm, 200 mm and 120 mm, odpowiadające odpowiednio trzem stopniom zbrojenia poprzecznego ρs: 0,16%, 0,20% i 0,33%. W celu porównania wpływu rozstawu strzemion na nośność belek na ścinanie zbadano element referencyjny bez zbrojenia poprzecznego.
EN
The paper presents the results of punching shear values with reinforcement based on calculations of two and four storey cast–in–place reinforced concrete flat plate system buildings with spans of 4 and 7 m in accordance with Armenian, Russian, European and American building codes under seismic action. The effect of punching shear on both interior and edge columns was carried out. All calculations by LIRA, Design Expert and RCM ACI–builder softwares were implemented. In contrast to Eurocode 2 (EN 2) and American Concrete Institute (ACI), the building codes of the Republic of Armenia (SNiP) do not include the influence of bending moment in shear stress equation. To analyze the systems finite element method (FEM) was used. The results of comparison analyses shown that according to SNiP the shear stresses do not exceed the limit even without reinforcement, whereas by foreign standards the differences between peak shear stresses with reinforcement and permissible shear reinforcement are marginal. To conclude, in shear stress condition the internal bending moments have a significant role, especially in seismic regions.
PL
W artykule przedstawiono wyniki pomiarów wytrzymałości na ścinanie w oparciu o obliczenia dla dwu i czteropiętrowych budynków żelbetowych o rozpiętości 4 i 7 m, zgodnie z ormiańskimi, rosyjskimi, europejskimi i amerykańskimi normami budowlanymi, w strefie oddziaływań sejsmicznych. Przeprowadzono badania dotyczące przebicia zarówno dla słupów wewnętrznych, jak i narożnych. Wszystkie obliczenia wykonano w programach LIRA, Design Expert i RCM ACI–builder. W przeciwieństwie do Eurokodu 2 (EN 2) oraz American Concrete Institute (ACI) przepisy budowlane Republiki Armenii (SNiP) nie uwzględniają wpływu momentu zginającego na równanie dla naprężeń stycznych. Do analizy układów konstrukcyjnych wykorzystano metodę elementów skończonych (MES). Wyniki analiz porównawczych wykazały, że zgodnie z SNiP naprężenia ścinające nie przekraczają wartości granicznych nawet bez użycia zbrojenia, podczas gdy według norm obcojęzycznych różnice pomiędzy ekstremalnymi naprężeniami ścinającymi z użyciem zbrojenia a dopuszczalnym ścinaniem zbrojenia są marginalne. Podsumowując, dla warunków dotyczących naprężenia ścinającego wewnętrzne momenty zginające mają duże znaczenie, zwłaszcza na obszarach objętych oddziaływaniami sejsmicznymi.
EN
Linear, nonlinear and test comparison analyses of flat plate slabs with shear reinforcement are presented in the article. Analyses of slabs with and without shear reinforcement by nonlinear simulations are introduced. The calculations of slabs without and with 0.16 m eccentricities were performed. For analyses finite element method were used. Design models of flat slab with column by “Lira SAPR” software were carried out. After the calculations whole results with experimental investigations were compared. The comparison analyses were shown, that presence of shear reinforcement far increase the capacity of slabs. Furthermore, the presence of shear reinforcement depends on eccentricity increases the axial force approximately 25%. Moreover, the difference between tests and nonlinear analyses results are about 6.4%.
PL
W artykule przedstawiono liniowe, nieliniowe i doświadczalne analizy porównawcze płaskich płyt stropowych ze zbrojeniem na ścinanie. Przeprowadzono analizy płyt ze wzmocnieniem i bez zbrojenia z wykorzystaniem symulacji nieliniowych. Wykonano obliczenia płyt bez mimośrodów i z mimośrodami 0,16 m. Do analiz wykorzystano metodę elementów skończonych. Wykonano modelowanie płaskiej płyty ze słupem za pomocą oprogramowania "Lira SAPR". Po zakończeniu obliczeń porównano wyniki z badaniami eksperymentalnymi. Analizy porównawcze wykazały, że obecność zbrojenia na ścinanie znacznie zwiększa zdolność płyt do przenoszenia obciążeń. Ponadto obecność zbrojenia na ścinanie zależy od mimośrodowości, a siła osiowa wynosi około 25%. Co więcej, różnica pomiędzy testami i wynikami analiz nieliniowych wynosi około 6,4%.
4
Content available remote Nośność belek zbrojonych na ścinanie prętami GFRP
PL
W artykule opisano metodę SFM (Shear Friction Model) do wyznaczania nośności na ścinanie zbrojonych elementów betonowych. Przedstawiono wyniki badań czterech belek betonowych o małej smukłości ścinania zbrojonych na ścinanie strzemionami GFRP (Glass Fiber Reinforced Polymer), bądź prętami GFRP z zakotwieniem główkowym. Porównano nośność na ścinanie badanych belek oznaczoną doświadczalnie z teoretyczną wyznaczoną metodą SFM.
EN
This paper describes the SFM (Shear Friction Model) to determine the shear capacity of reinforced concrete elements. In addition, the results of research of shear strength of concrete beams reinforced with GFRP bars (Glass Fiber Reinforced Polymer) are presented. Four beams with GFRP shear reinforcement (stirrups and headed bars) were analyzed. The article presents the comparison of experimentally investigated shear capacity and theoretical calculated according to SFM.
EN
Article is focused on explanation of two important problems met in design of slab–column connections – eccentric punching and design of punching shear reinforcement. Possible approaches used for consideration of unbalanced moments transferring are discussed.
EN
The purpose of the presented work was to test a newly developed punching shear retrofitting system for reinforced concrete flat slab-column connections. The proposed technique using shear bolt reinforcement allows increasing strength, ductility and rotational capacity of these connections. The paper discusses the role of transverse reinforcement in increasing post peak-load ductility and gives theoretical rationale for the proposed methodology. Shear bolts were developed at the University of Waterloo and tested in two series of tests on edge and interior slab-column connections. It is a special type of reinforcement for retrofitting of existing, previously built, flat slabs. The shear bolt consists of a headed vertical rod threaded at the other end for anchoring using a washer and nut system. The bolts are installed in holes drilled in a slab in concentric perimeters around the column. The results of the experimental work include connections tested under static loads. The load-deflection and load-strain curves are presented. The design methodology is discussed and the computed capacities of the specimens are compared to the experimental values.
PL
Celem prezentowanej tu pracy było sprawdzenie działania nowo rozwiniętej metody modernizacji połączeń zbrojonych, płaskich płyt ze słupami. Proponowana metoda pozwala na poprawienie wytrzymałości, ciągliwości i zdolności obrotowej tych połączeń za pomocą wzmocnienia śrubami płytowymi. W pracy przedyskutowano rolę poprzecznego zbrojenia na wzrost ciągliwości po nacisku szczytowym i wyprowadzono teoretyczne podstawy proponowanej metodologii. Śruby płytowe zaprojektowane na Uniwersytecie Waterloo w Kanadzie, przebadano w dwóch seriach eksperymentów, badając połączenia płyty ze słupem zarówno wewnętrzne, jak też blisko krawędzi. Jest to unikalny sposób wzmocnienia umożliwiający modernizację istniejących, dawno zbudowanych płaskich płyt. Śruba płytowa jest to gwintowany trzpień z okrągłym łbem na jednym końcu a gwintem na drugim, celem zamocowania za pomocą podkładki i nakrętki. Śruby płytowe są instalowane w otworach wierconych koncentrycznie wokół słupa. W przeprowadzonych doświadczeniach badano te połączenia pod naciskiem statycznym. Przedstawiono krzywe zależności ugięcia od nacisku oraz odkształcenia od nacisku. Przedstawiono metodę projektowania a obliczone komputerowo wytrzymałości próbek porównano z wynikami eksperymentalnymi.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.