The paper presents verification of selected flow time methods in terms of usability for sewerage systems design and sizing on the example of a model municipal flat drainage area of 2 km2. Namely, the sewerage system network was sized using three methods, that is, MGN with Blaszczyk’s formula, MGN with the precipitation model for Wroclaw and MWO with the precipitation model for Wroclaw, and then, the network functioning was verified for damming up on the area surface and flooding from drains using the hydrodynamic model SWMM 5.0. It was shown that the safe flow time method for sewerage system sizing is MWO using the criterion for the lack of damming up for the area and flooding from drains.
PL
W pracy symulowano działanie kanalizacji deszczowej zwymiarowanej trzema metodami czasu przepływu, tj.: MGN z wzorem Błaszczyka, MGN z wzorem opadów dla Wrocławia i MWO z wzorem opadów dla Wrocławia, dla modelowej zlewni miejskiej o powierzchni 2 km2 w terenie płaskim. Do symulacji hydrodynamicznych działania systemów kanalizacyjnych wybrano program SWMM 5.0 (Storm Water Management Model), opracowany przez Amerykańską Agencję Ochrony Środowiska (US EPA). Wskazano na bezpieczną metodę wymiarowania kanalizacji deszczowej (MWO) przy kryterium braku wylewów z kanałów.
2
Dostęp do pełnego tekstu na zewnętrznej witrynie WWW
The paper presents verification of selected flow time methods in terms of usability for sewage systems design and sizing on the example of a model municipal flat drainage area of the area of 2 km2. Namely, the sewage system network was sized using three methods, that is, MGN with Błaszczyk's formula, MGN with the precipitation model for WROCLAW and MWO with the precipitation model for Wroclaw, and then, the network functioning was verified for damming up on the area surface and flooding from drains using the hydrodynamic model SWMM 5.0. The precipitation model of Euler type II was used as the drainage area load in the conditions of Wroclaw, for which the probabilistic model of the maximum precipitation was developed. It was shown that the safe flow time method for sewage system sizing is MWO using the criterion for the lack of damming up for the area and flooding from drains.
PL
W pracy symulowano działanie kanalizacji deszczowej zwymiarowanej trzema metodami czasu przepływu, tj.: MGN z wzorem Błaszczyka, MGN z wzorem opadów dla Wrocławia i MWO z wzorem opadów dla Wrocławia, dla modelowej zlewni miejskiej o powierzchni 2 km2 w terenie płaskim. Do symulacji hydrodynamicznych systemów kanalizacyjnych wybrano program SWMM 5.0 (Storm Water Management Model), opracowany przez Amerykańską Agencję Ochrony Środowiska (US EPA). Jako obciążenie zlewni zastosowano opad modelowy Eulera typ II w warunkach hydrologicznych miasta Wrocławia (rzędna terenu 120,0 m nad poziom morza). Wskazano na bezpieczną metodę wymiarowania systemów kanalizacyjnych (MWO) przy kryterium braku wylewów z kanałów.
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.