Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  setting up
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available remote Relay protection settings determination using Its mathematical models
EN
The correct functioning of relay protection (RP) largely determines the stability of electric power systems (EPS). The key point, which in turn determines the behavior of protection in various emergency modes, is their setting. The existing methods and means often do not allow to guarantee the adequacy of protection setting to the real operating conditions, which is confirmed by the statistics of accidents in the EPS. The root cause of this problem is the impossibility using the software tools used in practice for relay settings calculation to reliably reproduce the transient processes in the power system. The EPS simulator – Hybrid Real-Time Power System Simulator (HRTSim), developed by the authors, allows to adequately reproduce the entire spectrum of normal and emergency processes for a power system of any dimension, topology and configuration through the use of detailed three-phase models of all EPS elements. Given this possibility, the task of detailed modeling of relay protection, including instrumental current and voltage transformers, becomes promising. The developed protection modeling tools in combination with the capabilities of the HRTSim allow the development of new methods for determining the relay protection settings. This article presents an algorithm for determining the polygonal and circular tripping characteristics of distance protection, and also presents graphic materials demonstrating the operation of this algorithm. This approach allows to adapt the settings to the real conditions of protection application in the power system, while minimizing the likelihood of their incorrect behavior.
PL
Od prawidłowego działania zabezpieczenia przekaźnikowego (RP) w dużej mierze zależy stabilność układów elektroenergetycznych (EPS). Kluczowym punktem, który z kolei determinuje zachowanie zabezpieczeń w różnych trybach awaryjnych, jest ich ustawienie. Istniejące metody i środki często nie pozwalają na zagwarantowanie adekwatności ustawień zabezpieczeń do rzeczywistych warunków eksploatacji, co potwierdzają statystyki wypadków w SEE. Podstawową przyczyną tego problemu jest niemożność wykorzystania narzędzi programowych stosowanych w praktyce do obliczania ustawień przekaźnika w celu niezawodnego odtworzenia procesów nieustalonych. Opracowany przez autorów symulator EPS - Hybrid Real-Time Power System Simulator (HRTSim) pozwala na adekwatne odwzorowanie całego spektrum procesów normalnych i awaryjnych dla systemu elektroenergetycznego o dowolnym wymiarze, topologii i konfiguracji poprzez zastosowanie szczegółowych trójstopniowych modeli fazowych wszystkich elementów EPS. Biorąc pod uwagę tę możliwość, zadanie szczegółowego modelowania zabezpieczeń przekaźników, w tym przekładników prądowych i napięciowych, staje się obiecujące. Opracowane narzędzia do modelowania zabezpieczeń w połączeniu z możliwościami HRTSim pozwalają na opracowanie nowych metod określania nastaw zabezpieczeń przekaźników. W artykule przedstawiono algorytm wyznaczania wielokątnych i kołowych charakterystyk wyzwalania zabezpieczeń odległościowych, a także przedstawiono materiały graficzne demonstrujące działanie tego algorytmu.
EN
The main problem preventing the use of digital relay protection mathematical models for real devices setting up is the confidentiality of the information about its internal configuration. This mainly concerns the input circuits (measuring part) of the protection, the components of which introduce the most significant errors. In this case, an arbitrary choice of the configuration may lead to incorrect results. The identification of the internal structure by standard methods, in particular by a real interpolation method, cannot be carried out in practice, due to the need to have input and output signals. In this regard, the purpose of the research was to develop a method of identification according to the time for formation of tripping signal. Identical signals were transmitted to real device and mathematical model of protection. The starting point of the time reference was the moment when the input signal reached a threshold; the final point was the time of tripping command appearance, unlike similar studies, where the time was determined by the closure of the output relay contacts. The research was carried out for 144 different combinations of the measuring part elements: auxiliary converters, analog filters, digital finite impulse response filters. As a result, the combination in which the smallest deviation from the tripping time of the real device was observed in all studied modes was selected as the most ‘optimal’. Performing such comparisons is the main way to make the model closer to real protection.
PL
Analizowano cyfrowe zabezpieczenie przekaźnikowe I jego model matematyczny przy założeniu, że nie jest znana jego struktura wewnętrzna. Zaproponowano metodę identyfikacji bazując na pomiarze czasu między przekroczeniem przez sygnał wejściowy wartości progowe a wyłączeniem.
PL
Realizacja zadań w ramach zabezpieczenia materiałowego Polskiego Kontyngentu Wojskowego /PKW/ jest możliwa przy spełnieniu kilku istotnych warunków. Pierwszym jest jednoznaczne określenie zadań i czasu trwania misji. Na tej podstawie powinien być opracowany etat PKW wraz z tabelą należności, które wskazują ilu żołnierzy i z jakim wyposażeniem będzie realizowało zadania mandatowe. Te informacje w połączeniu ze znajomością ustaleń dyrektywnych pozwalają określić całkowite potrzeby materiałowe. Znając wielkość potrzeb należy zdecydować nie wdając się w szczegóły, w jaki sposób i z jakich źródeł te potrzeby będą zaspakajane. Po dokonaniu tych ustaleń powinno mieć miejsce w miarę precyzyjne określenie kto /jaka jednostka wojskowa/, co /jaka jest treść zadania/, kiedy /w jakim czasie/ oraz w jaki sposób poszczególne zadania wykonywać. Nakładając na to sposób finansowania wydatków oraz organizacje kontroli i nadzoru, powstaje w miarę całościowy model pokazujący w jaki sposób potrzeby materiałowe PKW są zaspakajane.
EN
Implementation of tasks within the Polish Military Contingent /PMC/ material security is subject to several conditions. The first is the unambiguous definition of the tasks and the duration of the mission. On this basis should be developed time PMC together with a table of debts, which indicate how many troops and what equipment will be carried out military tasks. This information, combined with knowledge of the findings of the Basic to determine the total need for material. Knowing the size of the needs be decide without going into the details of how and from what sources these needs will be the foreign creditors. After these arrangements should take place as far as pinpointing who/ military unit/what/ is the content of the tasks/when/what time/and how to perform a particular task. By imposing on it's way to the payment of expenses and control and supervisory organizations formed as an overall model showing how the material needs of the NEC are foreign creditors.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.