Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  scyntylator
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents research results on the degradation of scintillators made out of thermoplastic composite materials based on polystyrene (PS). The samples were machined with the tools made out of three different material types: refractory alloys, synthetic diamonds, and diamonds mined from the Earth. The investigations enabled us to establish relations between the polystyrene scintillators’ machining conditions and the final roughness of their surface, as well as the impact of the surface quality on their optical stability. It was found that optimal feed of the preliminary machining was no more than 0.1 mm/tooth, and, for profiling or finishing milling, the rate was ca. 0.02 to 0.04 mm/tooth. Both an increase and decrease of the finishing milling parameters worsened the quality of the surface. It was proved that the optical elements can keep unchanged their characteristics during exploitation as long as 10 years if certain machining conditions are kept. The result can be attributed to high surface integrity in terms of surface microcracks, edge micro-damages, and inner stresses.
PL
W artykule przedstawiono wyniki badań nad degradacją materiału scyntylatorów wykonanych z termoplastycznych kompozytów na bazie polistyrenu (PS). Badane próbki obrabiano narzędziami z różnych materiałów: ze stopów trudnotopliwych, z diamentów sztucznych oraz z diamentów naturalnych. Na podstawie wyników ustalono zależności pomiędzy warunkami obróbki scyntylatorów polistyrenowych a wynikową topografią powierzchni, a następnie pomiędzy jakością powierzchni a stabilnością optyczną scyntylatorów. Ustalono, że optymalny posów dla obróbki zgrubnej wynosił nie więcej niż 0,1 mm/ostrze, zaś dla dokładnej i wykańczającej ok. 0,02÷0,04 mm/ostrze. Zarówno zwiększenie, jak i zmniejszenie tych wielkości pogarszało jakość powierzchni. Stwierdzono, że zachowanie określonych parametrów obróbki powoduje, iż elementy optyczne mogą zachowywać swoje właściwości eksploatacyjne nawet do 10 lat, prawdopodobnie ze względu na uzyskany wysoki stopień integracji powierzchni i minimalizację mikropęknięć, mikrouszkodzeń krawędzi oraz naprężeń wewnętrznych.
EN
The new direction of radiography is Flash-radiography (FR ) which doesn’t have intermediate data carriers (films and storage plates). FR produces a quick image. It provides low testing cost, and capability of multi-angle real time internal defects monitoring of the objects. In film radiography, if relative photometric density is more than 4, then the snapshots become virtually unreadable and they can be difficult to be digitized. Current film-free technologies do not have this disadvantage and, besides, give results in a digital form without special digitizing systems. Digital data contain radiation images of internal defects, expand the flawdetection possibilities and reduce testing cost. Flash-radiography is based on portable X-ray television, which allows the observation of X-ray testing results on a monitor screen. The internal defects examination from different angles may be carried out. Flash-radiography with digital solid-state transducers is the most perspective one with sensitivity up to 0.1% of examined metal’s thickness at resolution exceeding 10 pairs of lines per mm. Application of small-size movable solid-state transducers opens new technological capabilities. They can be located and moved in the zones where positioning of film holders and storage plates is impossible. The new X-ray mini technology expands the application of NDT. The examples of practical application of solid-state miniature transducers are presented.
PL
Nowym kierunkiem radiografii jest radiografia błyskowa (ang. flash radiograpy, FR), która nie ma pośrednich nośników danych (błon i płyt pamięciowych). FR tworzy szybki obraz. Zapewnia niskie koszty testowania oraz możliwość monitorowania obiektów pod kątem błędów wewnętrznych w czasie rzeczywistym. W radiografii błonowej, jeśli względna gęstość fotometryczna jest większa niż 4, migawki stają się praktycznie nieczytelne i mogą być trudne do digitalizacji. Obecne technologie wolne od błon radiograficznych nie mają tej wady, a poza tym dają wyniki w formie cyfrowej bez specjalnych systemów do digitalizacji. Dane cyfrowe zawierają obrazy promieniowania z defektów wewnętrznych, rozszerzają możliwości wykrywania wad i zmniejszają koszty testowania. Promieniowanie błyskowe jest oparte na przenośnym aparacie rentgenowskim, który umożliwia obserwację wyników badań rentgenowskich na ekranie monitora. Można przeprowadzić badanie wad wewnętrznych pod różnymi kątami. Promieniowanie błyskowe z cyfrowymi przetwornikami półprzewodnikowymi jest najbardziej perspektywiczne z czułością na poziomie do 0,1% badanej grubości metalu przy rozdzielczości przekraczającej 10 par linii na mm. Zastosowanie przenośnych przetworników półprzewodnikowych o niewielkich rozmiarach otwiera nowe możliwości technologiczne. Można je lokalizować i przemieszczać w strefach, w których nie jest możliwe pozycjonowanie uchwytów błon i płyt do przechowywania. Nowa mini technologia rentgenowska rozszerza zastosowanie NDT. Przedstawiono przykłady praktycznego zastosowania miniaturowych przetworników półprzewodnikowych.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.