Content available remote A new accelerated test for the evaluation of the protective properties of coatings
EN
Weathering of coatings by natural conditions at climatically different locations provides reliable data on the protective properties of coatings, it is however very time and cost consuming and non-practical for a quick evaluation of coatings. A number of diverse short time tests are therefore in usage by the development and optimization of new protective coatings. The most important requirements on such tests are the appropriate loading conditions, a sensitive quantitative detection of the coating deterioration, a short test duration as well as a good correlation with a natural weathering and a long term performance of coatings. By the development of a new short time test, we tried to fulfil these requirements as good as possible. For the accelerated aging of coatings we used the concept of the forced internal stress, induced by a thermal cycling, combined with an electrolytic, chemical or UV loading. By this kind of aging/loading both the natural weathering conditions and the standard laboratory tests can be simulated and performed at a shorter time. For the detection of the protection loss the impedance spectroscopy and the scanning Kelvin probe were chosen. Specific parameters from this kind of detection provide quantitative criteria for the quantitative evaluation of the protective properties of coatings in the early stages of their testing.
PL
Badania odporności powłok na czynniki atmosferyczne na stacjach terenowych w różnych warunkach klimatycznych dostarczają wiarygodnych danych na temat ochronnych właściwości powłok, jest to jednak metoda czasochłonna i kosztowna, w związku z tym niepraktyczna do szybkiej oceny powłok. W przypadku optymalizacji i opracowywania nowych wyrobów lakierowych używa się więc wielu różnorodnych metod badań przyspieszonych. Najważniejsze w takich metodach badań jest zapewnienie odpowiednich warunków narażenia, czuła ilościowa metoda wykrywania zmian, krótki czas trwania, jak również dobra korelacja z metodami badań w warunkach naturalnych i z zachowaniem się powłok w długim okresie czasu. Opracowując nowy krótkotrwały test, próbowaliśmy jak najlepiej spełnić te wymagania. W celu przyspieszenia starzenia powłok stosowaliśmy wymuszone naprężenia wewnętrzne, powodowane przez cykliczne zmiany temperatury w połączeniu z działaniem elektrolitu oraz narażeniami chemicznymi i UV. Rodzaj starzenia/narażenia pozwala zarówno na modelownie badań powłok w warunkach atmosferycznych, jak i standardowych badań laboratoryjnych oraz na skrócenie czasu badań. Do wykrywania zmian w powłokach, prowadzących do zmniejszenia ich właściwości ochronnych, wybrano metodę elektrochemicznej spektroskopii impedancyjnej (EIS) i metodę skanowania sondą Kelvina. Otrzymane tymi metodami charakterystyczne parametry umożliwiają ilościową ocenę ochronnych właściwości powłok we wczesnym etapie ich badania.
2
Content available remote Corrosion resistance of Zi-Ni coatings exposured to neutral salt spray
EN
Zn-Ni coatings (c.a. 30 wt.% Ni) have been deposited under galvanostatic conditions on a carbon steel substrate (St3S) from an ammonia bath. The corrosion resistance of the obtained coatings was examined using accelerated corrosion test (NSS - neutral salt spray) according to ISO 9227:2007. In order to compare corrosion properties of the as-deposited Zn-Ni coating, Zn-Ni coating after exposure to the NSS environment and Zn coating the potentiodynamic technique, electrochemical impedance spectroscopy (EIS) and scanning Kelvin probe (SKP) methods were used. The obtained results indicate that as-deposited and after NSS test Zn-Ni coatings exhibit better corrosion resistance in 5% NaCl than Zn coating. It was found that addition of nickel in zinc matrix improves corrosion properties of the oxide layer formed on the coating surface. Moreover Zn-Ni coating after exposure to the neutral salt spray have higher corrosion resistance in comparison with as-deposited Zn-Ni coating. It was stated that improved corrosion resistance of the Zn-Ni coatings after salt spray test could be attributed to the presence of Zn5(OH)8Cl2źH2O phase formed on the coating surface.
PL
Elektrolityczne powłoki Zn-Ni (Ni ok. 30% mas.) wytworzono w warunkach galwanostatycznych na podłożu stalowym (S235JR) z kąpieli amoniakalnej. Powłoki Zn-Ni poddano działaniu obojętnej mgły solnej (NSS) zgodnie z ISO 9227:2007. Porównano odporność korozyjną powłok: Zn, Zn-Ni w stanie wyjściowym oraz Zn-Ni po przyśpieszonych badaniach w komorze solnej. Stosowano następujące metody badań: technikę polaryzacji potencjodynamicznej, elektrochemiczną spektroskopię impedancyjną (EIS) i skaningową technikę z użyciem sondy Kelvina (SKP). Analiza wyników badań wskazuje, że powłoki Zn-Ni w stanie wyjściowym oraz poddane działaniu mgły solnej mają większą odporność korozyjną w środowisku 5% NaCl w porównaniu z powłoką Zn. Większa odporność korozyjna powłok stopowych Zn-Ni jest spowodowana przede wszystkim obecnością niklu - poprawia właściwości ochronne warstewki tlenkowej powstałej na powierzchni powłoki. Ponadto stwierdzono, że powłoki Zn-Ni w obecności mgły solnej charakteryzuje większa odporność korozyjna w porównaniu z powłokami Zn-Ni w stanie wyjściowym. Większą odporność korozyjną powłoki Zn-Ni poddanej działaniu mgły solnej można przypisać obecności produktów korozji na jej powierzchni, których głównym składnikiem jest faza Zn5(OH)8CI2źH2O.