Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 3

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  scale deposit
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A mathematical model of the steam superheater exchanger with distributed parameters has been developed. Scale deposits were assumed to be present on the internal tube surfaces. It was assumed that the inner tube surfaces are covered by a thin layer of scale deposits. The finite volume method was used to solve partial differential equations describing flue gas, tube wall and steam temperature. The developed modeling technique can especially be used for modeling tube heat exchangers when detail information on the tube wall temperature distribution is needed. The numerical model of the superheater developed in the paper can be used for modeling of the superheaters with complex flow arrangement accounting scales on the internal tube surfaces. Using the model proposed the detailed steam, wall and flue gas temperature distribution over the entire superheater can be determined. The steam pressure distribution along its path flow and the total heat transfer rate can also be obtained. The calculations showed that the presence of scale on the internal surfaces of the tubes cause the steam temperature decrease and the heat flow rate transferred from the flue gas to the steam. Scale deposits on the inner surfaces of the tubes cause the tube wall temperature growth and can lead to premature wear of tubes due to overheating.
PL
Omówiono wpływ wewnętrznej średnicy retorty na wyniki oznaczania zdolności reakcyjnej koksu (CRI) metodą Nippon Steel Corporation (NSC). Przeprowadzono ocenę możliwej destrukcji ścian retorty. Na podstawie przeprowadzonych eksperymentów stwierdzono, że wewnętrzna średnica retorty w wyniku korozji metalu zwiększa się, co pogarsza odtwarzalność wskaźników CRI i CSR.
EN
There was presented effect of the retort internal diameter for results of CRI reactivity test by Nippon Steel Corporation (NSC) method. There was shown evaluation of possible retort wall destruction. On the basis of carried out tests there is stated that retort internal diameter increases because of corrosion. It leads to impairment of CRI and CSR results reproducibility.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.