Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  sand flow rate
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
1
Content available Experimental Study of Air Lift Pump Delivery Rate
EN
This paper presents analysis of results of investigations of flow rate of sand (Qs) and water (Qw) in an air lift pump. The investigations were performed on an air lift pump test rig, constructed in a laboratory on a scale of 1:1. The paper describes the construction and working principle of this air lift pump test rig and presents a methodology of derivation of empirical formulas for calculation of sand and water flow rate. A comparative analysis of the values of the sand and water flow rate obtained in direct measurements with analogical values of flow rate calculated with use of the derived empirical formulas was carried out. The research scope encompassed the derivation of the aforementioned empirical formulas in the PVC air lift pump with the internal diameter of the discharge pipe d = 0.03 m by the fixed sand-water mix delivery heads H: 0.40 m, 0.80 m, 1.20 m. To derive the empirical formulas for calculation of the sand and water flow rate, dimensional analysis and multiple regression was applied. In the air lift pump being tested, the water and sand flow rate felt along with the rise in the delivery head and the water flow rate was higher than the sand flow rate. Air pressure in such devices cannot be lower than 110 kPa and cannot exceed 150 kPa as for higher values of air pressure the sand and water flow rate starts to fall. The values of the sand and water flow rate calculated with use of the derived formulas coincide very well with the values determined from the direct measurements.
PL
W artykule przedstawiono analizę wyników badań natężenia przepływu piasku (Qs) i wody (Qw) w podnośniku powietrznym. Badania wykonywano na wybudowanym w laboratorium w skali 1:1 stanowisku do badania podnośnika powietrznego. W artykule przedstawiono budowę i zasadę działania stanowiska badawczego oraz omówiono metodykę wyznaczenia empirycznych wzorów do obliczania natężenia przepływu piasku i wody. Przeprowadzono analizę porównawczą wartości natężenia przepływu piasku i wody wyznaczonych z bezpośrednich pomiarów z wartościami obliczonymi za pomocą wyznaczonych empirycznych wzorów. Zakres badań obejmował wyprowadzenie wzorów do obliczania natężenia przepływu piasku i wody w podnośniku powietrznym z tworzywa sztucznego PVC o średnicy wewnętrznej rurociągu tłocznego d = 0,03 m, przy zadanej wysokości podnoszenia mieszaniny piasku i wody H: 0,40 m, 0,80 m, 1,20 m. Do wyznaczenia empirycznych wzorów do obliczania natężenia przepływu piasku i wody zastosowano analizę wymiarową i metodę regresji wielokrotnej. W badanej konstrukcji podnośnika powietrznego wraz ze wzrostem wysokości podnoszenia mieszaniny piasku i wody, natężenie przepływu piasku i wody malało, a wartości natężenia przepływu wody były większe w stosunku do wartości natężenia przepływu piasku. W badanym urządzeniu ciśnienie powietrza nie może być mniejsze niż 110 kPa i nie powinno przekraczać 150 kPa, ponieważ przy wyższych ciśnieniach powietrza natężenie przepływu piasku i wody zaczynało spadać. Wartości natężenia przepływu piasku i wody obliczone za pomocą wyprowadzonych wzorów, bardzo dobrze pokrywały się z wartościami wyznaczonymi z bezpośrednich pomiarów.
EN
Analysis of results from a study on sand (Qz) and water (Qw) flow rate in an air lift pump was presented as well as the methodology of empirical formulas derivation to calculate those parameters. A comparative analysis of the values of sand and water flow rate from direct measurements and the calculated values was carried out. The scope of laboratory research encompassed derivation of the aforementioned empirical formulas to calculate water and sand flow rate for the plastic air lift pump with internal diameter of the delivery pipe d = 0.04 m, at fixed sand-water mix delivery heads of 0.40 m, 0.80 m and 1.20 m. Dimensional analysis and multiple regression were applied to derive the formulas. It was established that the water and sand flow rate decreased along with the increase of the delivery head, and the values of water flow rate were smaller than those of the sand flow rate. It was demonstrated that the air pressure in such devices cannot be lower than 110 kPa or exceed 175 kPa as at higher pressure values the sand and water flow rate started to fall. The values of sand and water flow rates calculated by the derived formulas coincided very well with the values determined by direct measurements using the 1:1 scale laboratory model.
PL
Przedstawiono analizę wyników badań strumienia objętości piasku (Qz) i wody (Qw) w podnośniku powietrznym oraz omówiono metody wyznaczania wzorów empirycznych do obliczania wartości tych parametrów. Przeprowadzono analizę porównawczą wartości strumienia objętości piasku i wody wyznaczonych w bezpośrednich pomiarach z wartościami obliczonymi za pomocą wzorów empirycznych. Zakres badań laboratoryjnych obejmował wyprowadzenie wzorów do obliczania wartości strumienia objętości piasku i wody w powietrznym podnośniku z tworzywa sztucznego o średnicy wewnętrznej rurociągu tłocznego d=0,04 m, przy zadanych wysokościach podnoszenia mieszaniny piasku i wody równych 0,40 m, 0,80 m i 1,20 m. Do wyznaczenia wzorów empirycznych do obliczania wartości strumienia objętości piasku i wody zastosowano analizę wymiarową i metodę regresji wielokrotnej. W przypadku badanej konstrukcji podnośnika powietrznego stwierdzono, że wraz ze wzrostem wysokości podnoszenia mieszaniny piasku i wody strumień objętości piasku i wody malał, a wartości strumienia objętości wody były mniejsze od wartości strumienia objętości piasku. Wykazano, że w urządzeniu tego typu ciśnienie powietrza nie może być mniejsze niż 110 kPa i nie powinno przekraczać 175 kPa, ponieważ przy wyższych wartościach ciśnienia powietrza strumień objętości piasku i wody zaczynał maleć. Wartości strumienia objętości piasku i wody obliczone za pomocą wyprowadzonych wzorów bardzo dobrze pokrywały się (korelowały?) z wartościami wyznaczonymi w pomiarach bezpośrednich na modelu laboratoryjnym w skali 1:1.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.