Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  samokalibracja
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
A new method of successive approximation ADC calibration without interruption of the main conversion process is proposed. The method is based on the use of information redundancy in the form of redundant positional number systems. The method is based on the selection and analysis of unused combinations in the redundant ADC conversion characteristic.
PL
Zaproponowano nową metodę kalibracji przetwornika AC z aproksymacją sukcesywną bez przerywania głównego procesu konwersji. Metoda opiera się na wykorzystaniu redundancji informacji w postaci redundantnych systemów liczb pozycyjnych. Metoda opiera się na selekcji i analizie niewykorzystanych kombinacji w charakterystyce redundantnej konwersji AC.
PL
W artykule przedstawiono problematykę pomiarów geodezyjnych na terenach rolnych. Nakreślono tradycyjne metody pomiarów i wskazano na przyczyny nieścisłości osiąganych wyników tych pomiarów ze stanem faktycznym na gruncie. Przy ocenie niezgodności pomiarów ze stanem faktycznym wykorzystano doświadczenia jednego z autorów (Beczkowski K.), który jest biegłym sądowym. Wskazano na możliwość wykorzystania metod fotogrametrycznych do wyznaczania granic działek i użytków, ze szczególnym uwzględnieniem Bezzałogowych Systemów Latających (BSL). Opisano metody przetwarzania zdjęć pomiarowych pozyskanych kamerami niemetrycznymi zamontowanymi na BSL. Wskazano na potrzebę samokalibracji kamer, w wyniku której wyznaczane są ich elementy orientacji wewnętrznej, co w przypadku dokładnie wyznaczonej osnowy fotogrametrycznej, podnosi dokładność opracowań końcowych – Numerycznego Modelu (Pokrycia) Terenu i ortofotomapy. W celu uzyskania wysokich dokładności wyznaczania elementów orientacji kamer pomiarowych w niniejszym opracowaniu wykorzystano specjalnie zaprojektowaną polową osnowę fotogrametryczną. W eksperymencie pomiarowym wykonano naloty fotogrametryczne dwoma rodzajami BSL – konstrukcją wielowirnikową (pionowego startu) i płatowcem (lotu horyzontalnego), który dodatkowo wyposażony był w pozycjonowanie GNSS środka rzutów z po prawkami w czasie rzeczywistym (RTK). Przetworzenie danych z nalotów wykonano w trybach GNSS RTK bez fotopunktów, GNSS z fotopunktami i GNSS bez fotopunktów. Następnie wyznaczono dokładności wszystkich przetworzeń i odniesiono je do granic wykazanych na mapie zasadniczej.
EN
The article presents the problem of surveying on farmland. It outlines the traditional methods of measurement and indicated the reasons for inaccuracies performance of these measurements with the actual situation on the ground. In assessing of non-compliance measurements with the actual situation based on the experience of one of the authors (Beczkowski K), which is a legal expert. Paper indicates the possibility of using photogrammetric methods for determining the boundaries of plots and land, with emphasis on Unmanned Aerial System (UAS). Methods of image processing measurements obtained by non-metric cameras mounted on BSL were described. The need of self-calibration of cameras was pointed because determination of interior orientation of the cameras increase the accuracy of the studies Digital Elevation Model (DEM) and orthophotomap. In order to achieve high accuracy of determining the orientation elements of cameras in this study a specially designed field photogrammetric framework were used. In the experiment, the photogrammetric measurement were made using two types of UAS - multirotor construction (VTOL) and airframe (horizontal flight), which also was equipped with a GNSS RTK receiver. Processing of photogrammetric data were carried out in modes GNSS RTK without ground control points, GNSS with control points, GNSS without control points. Then the accuracy of all transformations were determined and compared to the principal map.
PL
Badanie średnioformatowej lustrzanki cyfrowej Mamiya ZD, wyposażonej w sensor CCD (format 48x36 mm, rozdzielczość 5328x4000, piksel p'HV = 9 μm), obejmowało określenie dystorsji radiometrycznej sygnału oraz dokładności samokalibracji i opracowania punktowego w bliskim zasięgu. Ocenę dystorsji sygnału sensora CCD FTF4052C przeprowadzono w autorskim programie "Image Analysis". Obrazy rejestrowane aparatem Mamiya ZD charakteryzuje wysoka jakość radiometryczna sygnału. Średnie odchylenie standardowe wyznaczonej jasności I wyniosło StdDev = 1.1 (R: StdDev = 1.5, G: StdDev = 1.3, B: StdDev = 2.3). Fotogrametryczne badanie aparatu Mamiya ZD, wyposażonego w 2 obiektywy serii Mamiya 645AF, wykonano na podstawie 3. konfiguracji zdjęć zbieżnych (17, 13, 11) pola testowego, które tworzyło ca 220 sygnalizowanych punktów, w tym 60 punktów kodowanych (kod 14 bit). Zdjęcia rejestrowano z odległości ca YF = 5 m. Automatyczny pomiar punktów na obrazach cyfrowych oraz rozwiązanie metodą wiązek, łącznie z samokalibracją, wykonano programem AICON 3D Studio. Optymalny model aproksymujący błędy systematyczne obrazu zawierał 5 parametrów: dystorsję radialną symetryczną A1, 2 , dystorsję radialną asymetryczną i tangencjalną B1, 2 oraz afiniczność sensora C1. Najwyższą dokładność uzyskano dla konfiguracji 11 zdjęć zbieżnych. Wartość Sigma 0 po wyrównaniu wyniosła σ0 = ±0.055 pxl. Parametry orientacji wewnętrznej: cK , x’o , y’o wyznaczone zostały z dokładnością ±0.15 pxl (obiektyw 645AF 45 mm) oraz ±0.35 pxl (obiektyw 645AF 80 mm). Odchylenia standardowe RMS wyznaczonych współrzędnych X, Y, Z wyniosły odpowiednio: SXZ = ±0.02÷0.03 mm, SY = ±0.07 mm oraz SXZ = ±0.01÷0.02 mm, SY = ±0.04 mm. Zastosowanie lustrzanki Mamiya ZD do punktowych opracowań bliskiego zasięgu wymaga kombinowanego wyrównania metodą wiązek, połączonego z samokalibracją równoczesną on-the-job. Względna dokładność opracowania jest możliwa z dokładnością rzędu ca 1: 125 000 (obiektyw 645AF 45 mm) oraz 1: 200 000 (obiektyw 645AF 80 mm).
EN
Quality of the radiometric signal, measuring potential, and the photogrammetric selfcalibration of the Mamiya ZD medium format digital SLR camera were studied. The DSLR Mamiya ZD camera examined was equipped with 2 exchangeable objectives: Mamiya 645AF 45 mm and 645AF 80 mm. The noise level and the signal distortion in the CCD FTF4052C sensor (format size of 48x36 mm, full resolution of 53284000) was determined with "Image Analysis" software developed by the author. Analysis of 30 image sequences showed the Mamiya ZD camera to be characterised by a low noise level and a high quality of data processing module. In the brightness channel I, the mean standard deviation amounted to StdDev = 1.1 (channel R: StdDev = 1.5; channel G: StdDev = 1.3; channel B: StdDev = 2.3). The photogrammetric research was conducted in the test field at Institute of Photogrammetry and Remote Sensing, Dresden University of Technology. The test field consisted of a total of 220 signalised, retro-reflective points (60 coded points, 14 bit code). The test field was registered from the distance of ca YF = 5 m. The camera was calibrated and point determination accuracy was examined based on 3 types of digital image networks which consisted of configurations of 17, 13, and 11 convergent photos. The bundle adjustment, including on-the-job self-calibration with additional parameters for modelling systematic imaging errors, was carried out with the AICON 3D Studio software package (AICON 3D Systems GmbH, Germany). The correction terms contained additional parameters for compensation of radial-symmetric (A1, 2. 3) and decentering (B1, 2) lens distortion as well as affinity and shear of the digital image coordinate system (C1, 2). Additional parameters were implemented in individual calibrations (7, 6, 5). All the points in the digital images were measured fully automatically with the AICON 3D Studio program. The study showed the highest 3D point positioning accuracy to be achieved with 11 convergent photos. The optimal model of systematic errors consisted of 5 parameters (A1, 2 , B1, 2 , C1). The point accuracy was independent of the number of calibration parameters. After the combined bundle adjustment with the self-calibration, the Sigma 0 mean value amounted to σ0 = ±0.055 pxl. The basic parameters of interior orientation: cK , x’o , y’o were determined with the accuracy of ±0.15 (for the photos registered with 645AF 45 mm objective) and ±0.35 pxl (for the 645AF 80 mm objective). The RMS standard deviation of calculated coordinates amounted to: SX = ±0.03 mm, SY = ±0.07 mm, SZ = ±0.02 mm and SX = ±0.02 mm, SY = ±0.04 mm, SZ = ±0.01 mm, respectively. In the close range test application presented, using the Mamiya ZD medium format DSLR camera, the relative accuracies of 3D coordinate analytical estimates achieved in the object space were 1: 125 000 (for the photos registered with 645AF 45 mm objective) and 1:200 000 (645AF 80 mm objective).
PL
Badanie jakości radiometrycznej sygnału i samokalibrację fotogrametryczną przeprowadzono dla lustrzanki cyfrowej Kodak DCS Pro 14n wyposażonej w sensor CMOS (format 36×24 mm, rozdzielczość 4500×3000). Ocenę poziomu szumów i dystorsji sygnału przetwornika CMOS IBIS4-14000 (FillFactory NV, Belgia) wykonano w autorskim programie "Image Analysis" napisanym w języku Delphi 7. Program oblicza średnia wartość poziomu szarości, wariancje oraz odchylenie standardowe dla każdego piksela w zdefiniowanych obszarach zainteresowania sekwencji obrazów. Na podstawie analizy sekwencji 30 obrazów stwierdzono, _e obrazy rejestrowane aparatem Kodak DCS Pro 14n charakteryzują się niskim poziomem szumów i wysoka jakością układu przetwarzającego dane. Dla jasności I średnie odchylenie standardowe wyniosło SdtDev = 1.5 (kanał R: SdtDev = 1.7, kanał G: SdtDev = 1.6, kanał B: SdtDev = 2.1). Samokalibracje on-the-job z dodatkowymi parametrami modelującymi błędy systematyczne obrazu: A1 , A2 , B1 , B2 , C1 , C2 , łącznie z wyznaczeniem współrzędnych 3D dla ca 110 sygnalizowanych punktów (30 punktów kodowanych, kod 12 bit) pola testowego, przeprowadzono programem AICON 3D Studio firmy AICON Systems GmbH, Niemcy. Siec zdjęć tworzyła konfiguracja 11 zdjęć zbieżnych wykonanych z odległości ca YF = 5 m. Wszystkie punkty na zdjęciach cyfrowych zostały pomierzone w pełni automatycznie. Średnia wartość Sigma 0 po wyrównaniu metoda wiązek wyniosła _0 = ±0.055 piksela. Podstawowe elementy orientacji wewnętrznej: cK, x¢ 0 , y¢ 0 wyznaczone zostały z dokładnością ±0.2 piksela. Średnie odchylenie standardowe wyznaczonych współrzędnych wyniosły odpowiednio: SXY = ±0.03 mm, SZ = ±0.04 mm. W prezentowanej aplikacji bliskiego zasięgu przy zastosowaniu profesjonalnej lustrzanki cyfrowej Kodak DCS Pro 14n otrzymano względną dokładność opracowania analitycznego rzędu ca 1: 150 000.
EN
The study on the radiometric signal quality and the photogrammetric self-calibration was performed for the Kodak DCS Pro 14n SLR digital camera with the CMOS sensor (format size of 36×24 mm, full resolution of 4500×3000). The examination of noise level and the signal distortion in the CMOS IBIS4-14000 (Fill Factory NV, Belgium) converter was determined in the "Image Analysis" authors’ software, which was written with the Delphi 7 programming tools. The program calculates mean grey level value, variance and standard deviation for each pixel in the defined areas of interest in the image sequences. Based on the analysis of 30 image sequences, it was found that low noise level and high quality of data processing module were characteristic for the Kodak DCS Pro 14n camera. In the brightness channel I, the mean standard deviation amounted to SdtDev = 1.5 (channel R: SdtDev = 1.7, channel G: SdtDev = 1.6, channel B: SdtDev = 2.1). The on-the-job self-calibration with additional digital imaging systematic errors modelling parameters: A1, A2, B1, B2 , C1, C2 and the calculation with ca 110 signalised points 3D coordinates (30 coded points, 12 bit code) on a test field, was determined in the AICON 3D Studio program (AICON Systems GmbH, Germany). The digital image network was created by the configuration of eleven convergent photos registered from the distance of ca YF = 5 m. All points in digital images were measured completely automatically. The Sigma 0 mean value after the combined bundle adjustment amounted to _0 = ±0.055 pxl. Basic parameters of interior orientation: cK, x¢ 0 , y¢ 0 were determined with the accuracy of ±0.2 pxl. The mean standard deviation of calculated coordinates amounted to: SXY = ±0.03 mm, SZ = ±0.04 mm. In the presented close range application, when the Kodak DCS Pro 14n SLR digital camera was used, a relative accuracy of 3D coordinates analytical estimation of 1: 150 000 in the object space was achieved.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.