Content available remote Mixing effects in the river downstream from pollution discharge point
EN
This paper follows the propagation of pollution in a river with a rectangular crosssection of the river bed and a variable cross-sectional velocity. The calculations were made for steady flows and steady pollutant concentrations. To approximate the velocity distribution in the river bed a set of equations for current and vorticity functions was solved. The distribution of pollutant concentrations in the river was calculated from a bidirectional advection and turbulent diffusion equation. Analysis of the distribution of concentrations leads to the conclusion that the effects of transverse advection associated with a lateral inflow of pollutants disappear relatively quickly. Therefore, the distribution of concentrations in cross sections further downstream from the point of pollutant discharge can be determined quite accurately just from an advection-diffusion model, with no transverse advection effects included. Such a level of accuracy is usually sufficient to assess the impact of a pollution source on the aquatic environment. The transverse mixing of pollutants in the stream proceeds slowly and creates a large mixing zone in which the concentrations of pollutants (low but still significant for water quality) can be detected in cross-sections that are remote from the pollutant discharge point. Transverse advection may be ignored while calculating concentrations in remote cross sections at straight watercourse sections and in steady state conditions.
PL
W pracy opracowano metodę badania współdziałania wentylacji nawiewno-wyciągowej z użyciem SF6 jako znacznika. Rozpatrzono wpływ charakterystyk przepływowych wewnątrz wyciągu i w jego otoczeniu na emisję zanieczyszczeń powietrza. Wyniki potwierdzają możliwość zastosowania zaproponowanej metodyki do wspomagania projektowania oraz sprawdzania skuteczności wyciągów.
EN
The paper demonstrates the application of tracer gas method (SF6) for testing the cooperation of supply-exhaust ventilation system. An influence of flow characteristics inside the fume cupboards and its surroundings on the air pollutants emission was investigated. The results confirm the possibility of using the proposed method for design and evaluation of the efficiency of fume cupboards.
PL
Przedstawiono sposób oceny skażenia powietrza atmosferycznego w regionach. Obliczenia wykonano dla obszaru Karkonoszy, leżącego na styku Niemiec, Czech i Polski. Badano rozkłady średniorocznych stężeń SO2, CO, pyłu, NO2 i stężeń ozonu. Pola imisji modelowano na podstawie wyników pomiarów wykonanych w latach 1998-2000. Stosowano sieci neuronowe. Wykazano, że w omawianym okresie znacznie zmieniły się rozkłady stężeń średniorocznych SO2 i CO, w nieznacznym stężenia pyłu, a NO2 i ozonu pozostały praktycznie niezmienione.
EN
A method for atmospheric air pollution in regions was presented. Calculations were made for the area of Karkonosze Mountains, located on the border of Germany, Czech and Poland. Distributions of mean annual concentrations of SO2, CO, particulate matter, NO2 and ozone concentrations were studied. Imission fields were modeled based on data from measurements performed in the years 1998-2000. Neural networks were applied. It was showed that the distributions of mean annual concentrations of S02 and CO changed significantly during the studied period, particulate matter concentrations changed only slightly, while NO2 and ozone concentrations remained practically unchanged.
4
Content available remote Homogenisation of newtonian liquids in a folow using static mixers
EN
This paper presents a description of the measuring stand (picture 1), methodology and results of the mixing process for water and 15 % solution of NaCl. The solution was mixed with theuse of a static mixer (picture 2) with canal passages (type 1) and with every second canal plugged at the end (type2). The (1) and (2) equations describe the influence of the turbulence level, Re, and the number of the elementary mixing inserts n on the mixing degree I. The (3) and (4) equations show the corelation between the flow resistance coefficient lambda and the variables mentioned earlier. It has also been observed that both the mixing degree and lambda coefficient correlated more strongly with the value of the Reynolds number than with the number of mixing inserts. More over, the influence of the Reynolds number decreased in favour of variable n along with the complexity of mixer construction.
PL
Opisano budowę stanowiska pomiarowego (rys. 1), metodykę i wyniki badań procesu mieszania wody i 15 % roztworu NaCl za pomocą mieszadła statycznego (rys. 2) z kanałami przelotowymi (typ 1) oraz z co drugim kanałem zaślepionym na wylocie (typ 2). Równaniami (1) i (2) opisano wpływ poziomu burzliwości przepływu Re i liczby elementarnych wkładek mieszajacych n na stopień zmieszania I. Równania (3) i (4) pokazują zależność współczynnika oporów przepływu lambda od wymienionych zmiennych. Stwierdzono, że wartości tak stopnia zmieszania, jak i współczynnika lambda silniej są związane z wielkością liczby Reynoldsa niż z liczbą wkładek mieszających, przy czym wpływ liczby Re maleje na korzyść zmiennej n wraz z konstrukcyjną złożonością mieszadła.