Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  reverberation chamber
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In order to investigate the effect of the surface shape on the performance of perforated panels, three non-flat shapes were considered for perforated panel with their absorption performance compared with the usual shape of the (flat) perforated panel. In order to simulate the absorption coefficient of a non-flat perforated panel, the finite element method was implemented by the COMSOL 5.3a software in the frequency domain. Numerical simulation results revealed that all the shapes defined in this paper improve the absorption coefficient at the mid and high frequencies. A and B shapes had a higher performance at frequencies above 800 Hz compared to the flat shape. Also, shape C had a relative superiority at all frequencies (1–2000 Hz) compared to the reference shape; this superiority is completely clear at frequencies above 800 Hz. The maximum absorption coefficient occurred within the 400–750 Hz range. After determining the best shape in terms of absorption coefficient (shape C), a perforated panel of 10 m2 using fiberglass fibers and desired structural properties was built, and then it was also subjected to a statistical absorption coefficient test in the reverberation chamber according to the standard. The results of the statistical absorption coefficient measurement showed that the highest absorption coefficient was 0.77 at the frequency of 160 Hz. Also, to compare the experimental and numerical results, these conditions were implemented in a numerical environment and the statistical absorption coefficient was calculated according to the existing relationships. A comparison of the numerical and laboratory results revealed acceptable agreement for these two methods in most frequency spectra, where the numerical method was able to predict this quantity with good accuracy.
PL
Internet rzeczy jest zjawiskiem wywodzącym się od sieci sensorowych, te zaś są wynikiem zrozumienia korzyści wynikających z „dania rzeczom głosu”, czyli umożliwienia miliardom czujników, mierników, liczników, sond, sensorów komunikowania swoich odczytów bez ingerencji człowieka. Z uwagi na niskie wymagania dotyczące przepustowości, systemy te wykorzystują wąskie kanały częstotliwościowe, ze względów propagacyjnych najczęściej ulokowane w pasmach poniżej 1 GHz, co sprzyja dużym zasięgom albo dobrej penetracji sygnału do wnętrz budynków. Omówiono kilka wybranych systemów transmisyjnych dla podkreślenia różnorodności rozwiązań w warstwie fizycznej. Odrębny rozdział poświęcono zagadnieniu zagłuszania, które wydaje się jedną z najskuteczniejszych – mimo iż mało wyrafinowanych – metod zaburzania czy blokowania transmisji w wąskopasmowych systemach IoT. Przegląd literaturowy wskazuje na liczne próby zapobiegania skutkom zagłuszania lub – alternatywnie – wykorzystania zagłuszania do ochrony transmisji przed podsłuchem. Z powodu wysokich czułości systemów IoT, pomiar ich wydajności w warunkach zakłóceniowych bądź wielodrogowych wymaga odpowiedniej adaptacji zaplecza laboratoryjnego, umożliwia jednak uzyskanie miarodajnych wyników dotyczących rekomendowanych nastaw w warunkach granicznie wysokich tłumień czy niskich wartości nośnej do szumu i zakłóceń oraz transmisji wielodrogowej.
EN
The Internet of Things is a phenomenon derived from sensor networks, and these are the result of understanding the benefits of "giving things a voice", i.e., enabling billions of sensors, meters, gauges, probes, sensors to communicate their readings without human intervention. Due to low bandwidth requirements, these systems use narrow frequency channels, most often located in bands below 1 GHz for propagation reasons, which favors long ranges or good signal penetration into building interiors. Several selected transmission systems were discussed to emphasize the diversity of solutions in the physical layer, devoting a separate chapter to the jamming issue, which seems to be one of the most effective – although not very sophisticated – methods of disrupting or blocking transmissions in narrowband IoT systems. The literature review shows numerous attempts to prevent the effects of jamming or, alternatively, to use jamming for protecting transmissions from eavesdropping. Due to the high sensitivity of IoT systems, measuring their performance in disturbed or multi-path conditions requires appropriate adaptation of the laboratory facilities, however, it allows obtaining reliable results regarding the recommended settings in conditions of extremely high attenuation or low carrier to noise and interference values as well as multi-path transmission.
PL
Celem badań było określenie możliwości oraz wskazanie sposobu zwiększenia izolacyjności akustycznej ścian wewnętrznych i zewnętrznych wykonanych w technologii szalunku traconego ICF (ang. Insulated Concrete Forms) z pustaków styropianowych. Wykonano szereg badań doświadczalnych izolacyjności akustycznej modeli ścian z pustaków styropianowych z rdzeniem betonowym niemodyfikowanym oraz modyfikowanym różnymi dodatkami i ścian z dodatkowymi warstwami. Analiza wyników badań pozwala na stwierdzenie, że wprowadzenie wypełniaczy do betonu (perlit drobny, perlit gruby, guma drobna, guma gruba) nie powoduje wyraźnej poprawy izolacyjności akustycznej. Modyfikacje polegające na dodaniu warstw zewnętrznych w postaci płyt gipsowo-kartonowych nie prowadziły do poprawy izolacyjności akustycznej. W wielu przypadkach po modyfikacji rdzenia betonowego pojawiła się dodatkowa częstotliwość rezonansowa, co powodowało pogorszenie wskaźników izolacyjności akustycznej. Wyraźną poprawę własności akustycznej uzyskano dla ściany z dodatkowymi warstwami zewnętrznymi w postaci kratownicy drewnianej wypełnionej wełną mineralną.
EN
The aim of the research was to determine the possibilities and indicate how to increase the acoustic insulation of internal and external walls made in the ICF (Insulated Concrete Forms) technology of polystyrene blocks. A series of experimental tests of acoustic insulation of walls made of polystyrene blocks with an unmodified concrete core and modified with various additives and walls with additional layers were carried out. The analysis of the test results shows that the introduction of fillers into concrete (fine perlite, coarse perlite, fine rubber, coarse rubber) does not significantly improve the acoustic insulation. Modifications consisting in adding external layers in the form of plasterboards did not lead to an improvement in acoustic insulation. In many cases, after the modification of the concrete core, an additional resonance frequency appeared, which resulted in deterioration of the acoustic insulation indexes. A clear improvement in acoustic properties was obtained for the wall with additional external layers in the form of a wooden lattice filled with mineral wool.
PL
W artykule zaprezentowano system do wspomagania pomiarów akustycznych prowadzonych w komorze pogłosowej. Jego zadaniem jest pozycjonowanie próbek badanych materiałów rozpraszających dźwięk względem źródeł dźwięku i mikrofonów pomiarowych. Zaprezentowano konstrukcję mechaniczną urządzenia, zasadę sterowania nim oraz przykładowe wyniki pomiarów. Urządzenie zaprojektowano tak, aby jego wpływ na warunki akustyczne w komorze był jak najmniejszy.
EN
The article presents the system for automated acoustic measurements taken In an anechoic chamber Its task is to position the samples of tested sound dif-fusing materials related to the sources of sounds and the measurement microphones. The mechanical construction of the deyjce is presented as well as ttie principle of its control and the sample results of measurements. The design of the system is aimed at as little effect on the acoustic conditions in the chamber as possible.
PL
Zaprezentowano wyniki pomiaru rozkładu natężenia pola elektromagnetycznego w komorze rewerberacyjnej Laboratorium Kompatybilności Elektromagnetycznej Politechniki Wrocławskiej w dwóch płaszczyznach na granicy przestrzeni pomiarowej. Wykazano także, że metoda kalibracji i walidacji komory rewerberacyjnej, w szczególności dla najniższych częstotliwości (w otoczeniu LUF), powinny zostać zweryfikowane, aby pozytywne wyniki walidacji zakresu częstotliwości pracy i wielkości przestrzeni pomiarowej komory rewerberacyjnej gwarantowały poprawne warunki i wyniki testów.
EN
The paper presents the measurement results of electromagnetic field strength distribution in the reverberation chamber of EMC laboratory of Wrocław University of Technology in two planes on the border of the test volume. It was also shown that the method of calibration and validation of reverberation chamber, in particular for frequencies dose to the Iowest use-able frequency (LUF) should be verified that the positive results of the validation frequency range and size of chamber's test volume guarantee the correct test conditions and test results.
EN
In this paper some vital issues regarding the use of reverberation chambers for the purpose of imitating real propagation environments are discussed. It was shown that the reverberation chamber-based emulator appears to provide an excellent test environment for outdoors rather than indoor channels, which statement seems to be independent of the chamber volume. Moreover, for the purpose of a wireless channel emulation the quantitative impact of the load applied to the chamber on RMS delay spread (THMS) seems to be of great importance, too. From the presented considerations it follows that some initial measurements of a loaded chamber are necessary before the final coding scheme/system performance evaluation. The main purpose of the measurement is to provide Information on the permissible chamber load. The solution proposed by the authors as an alternative to the time-consuming measurements is the use of properly tuned reverberation chamber simulator. Some basic observations regarding such a simulator as well as its advantages are also discussed.
PL
Omówiono podstawowe zagadnienia związane z zastosowaniem komory rewerberacyjnej do imitowania rzeczywistego środowiska propagacyjnego. Wskazano, że komora rewerberacyjna jest doskonałym narzędziem do symulowania kanału radiowego raczej na zewnątrz budynków (outdor) niż w ich wnętrzu (indor) i stwierdzenie to wydaje się być zasadne niezależnie od objętości komory. Jednakże znaczący wpływ na rozmycie czasowe rR.fs ma obciążenie komory rewerberacyjnej stosowanej do symulacji kanału radiowego. Z przedstawionych rozważań wynika, że konieczny jest pomiar charakterystyki kanału obciążonej komory przed badaniem osiągów systemu czy typu kodowania. Podstawowym celem jest bowiem określenie, czy nie osiągnięto dopuszczalnego obciążenia komory. Alternatywą do czasochłonnych pomiarów jest zaproponowane przez autorów stosowanie strojonego symulatora komory rewerberacyjnej. Obserwacje dotyczące symulatora oraz jego zalety przedyskutowano w artykule.
PL
Przedstawiono przegląd metod pomiaru skuteczności ekranowania materiałów tekstylnych, obudów i komponentów za pomocą pojedynczej komory rewerberacyjnej lub ich zestawu. Zastosowanie komór rewerberacyjnych do pomiaru skuteczności ekranowania umożliwia znaczne rozszerzenie zakresu częstotliwości oraz zwiększenie dynamiki pomiarów, kosztem dolnej granicy częstotliwości pomiarowych, która w stosunku do innych metod zwiększa się od kilkuset MHz do nawet pojedynczych GHz. Jest to podstawowe ograniczenie metod pomiarowych wykorzystujących komory rewerberacyjne w pomiarach, związane bezpośrednio z wymiarami geometrycznymi stosowanych komór rewerberacyjnych. Możliwe wzajemne oddziaływanie elementów stanowiska pomiarowego, w tym dodatkowych komór, którego skutkiem jest zmiana rozkładu pola elektromagnetycznego lub zmiana dobroci komory rewerberacyjnej, a także statyczny charakter mierzonych wartości wymagają stosowania odpowiednich procedur pomiarowych z licznymi rejestracjami wyników pomiarów oraz dużej staranności i dokładności pomiarów, a także uwzględniania odpowiednich współczynników korekcyjnych dla uzyskania wiarygodnego wyniku pomiaru. Aspekty te, jak i metody pomiarów różnych elementów zostały opisane w niniejszym artykule.
EN
The paper present review of shielding effectiveness measurements of cable assemblies, cables, connectors, waveguides passive microwave components, planar textile materials, gaskets and enclosures using single reverberation chamber or set of reverberation chambers. Application of reverberation chambers to shielding effectiveness (SE) measurements allows to expand frequency range as well as dynamics of measurements, but lower usable frequency (LUF) is much higher (from several hundreds MHz up to single GHz) when comparing to other SE measurements methods. LUF is the main limitation of measurement methods using reverberation chambers, which is direct connected with the geometrical size of reverberation chamber. Special measurement procedures are required for measurement of shielding effectiveness using single reverberation chamber or set of chambers because of statistical character of measured values. Mutual interactions of chambers as well as interactions with other elements of measurement set-up's can change the field distribution in chambers and its quality factor Q. So SE measurements using reverberation chambers require recording of numerous measurements results as well scrupulous and accurate measurements with additional corrections coefficients, which have to be determined before or during measurements. All these aspects have been presented in present paper.
PL
Omówiono możliwość zastosowania komory rewerberacyjnej pracującej w trybie przestrajania do pomiaru zastępczej mocy promieniowanej izotropowo (EIRP) przez radiowe urządzenia nadawcze. Przedstawiono także przykładowe testy oraz uzyskane wyniki pomiaru EIRP dla małych urządzeń oraz ich porównanie z wynikami uzyskiwanymi w komorze bezodbiciowej.
EN
Since a few years industrial companies as well as test houses and universities have invested in new type of test facilities- reverberation chambers (RC). These new test facilities allow performing compliant EMC tests, especially radiated emission tests trough radiated power measurement. RC can be successfully applied to measurement of effective isotropic radiated power (EIRP) of radio transmitters. In the paper some information about the measurement method of radiated power in RC has been described in details. Some measurement results for transmitter model and real handheld radio transmitters have been presented too. Comparison of measurement results for different test methods confirms that reverberation chamber can be use to EIRP measurement for radio transmitters with the same accuracy.
EN
In this paper the problem of evaluation of assessment of absorptive seats is discussed. The results of sound absorption of soft seats in different configurations are presented, made in reverberant chamber in ITB. The influence of kind of arrangement of seats in reverberant chamber (configuration, density) and influence of boundary effect are analyzed, that mean the influence of shielding of the edges of the sample of the tested chairs with non - absorptive l meters high barrier regarded to 1 m2 of surface.
PL
W referacie omawiane są problemy oceny właściwości dźwiękochłonnych krzeseł. Przedstawiono wyniki pomiarów chłonności akustycznej miękkich krzeseł, wykonanych w komorze pogłosowej w Zakładzie Akustyki ITB. Analizowany jest wpływ sposobu rozmieszczenia krzeseł w komorze pogłosowej (układ i gęstość) oraz wpływ efektów brzegowych, czyli osłaniania obrzeży próbki krzeseł płytami odbijającymi, na wartość współczynnika pochłaniania dźwięku i chłonności akustycznej, odniesionej do 1 m powierzchni.
PL
W pracy omówiono trzy, stosunkowo nowe zagadnienia, związane z badaniami kompatybilności elektromagnetycznej urządzeń i układów elektronicznych: obciążenia nieliniowe i analiza harmonicznych prądu zasilania w świetle ostatnich zmian norm międzynarodowych, komory rewerberacyjne oraz metody pomiaru emisji i odporności na zaburzenia elektromagnetyczne układów scalonych.
EN
Some relatively new EMC testing methods are shortly described. These are: nonlinear loads and analysis of harmonic generated in power lines, reverberation chambers, electromagnetic emissions from ICs and immunity (susceptibility) of integrated circuits to electromagnetic disturbances.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.