Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 5

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  resonant controller
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The paper presents a three-phase grid-tied converter operated under unbalanced and distorted grid voltage conditions, using a multi-oscillatory current controller to provide high quality phase currents. The aim of this study is to introduce a systematic design of the current control loop. A distinctive feature of the proposed method is that the designer needs to define the required response and the disturbance characteristic, rather than usually unintuitive coefficients of controllers. Most common approach to tuning a state-feedback controller use linear-quadratic regulator (LQR) technique or pole-placement method. The tuning process for those methods usually comes down to guessing several parameters. For more complex systems including multi-oscillatory terms, control system tuning is unintuitive and cannot be effectively done by trial and error method. This paper proposes particle swarm optimization to find the optimal weights in a cost function for the LQR procedure. Complete settings for optimization procedure and numerical model are presented. Our goal here is to demonstrate an original design workflow. The proposed method has been verified in experimental study at a 10 kW laboratory setup.
PL
W artykule przedstawiono metody kompensacji wyższych harmonicznych prądu dla dwupoziomowego przekształtnika AC-DC sprzęgniętego z systemem elektroenergetycznym. Wykorzystany algorytm Bezpośredniego Sterowania Mocą z modulatorem wektorowym (DPCSVM) został wyposażony w dodatkowy moduł kompensacji harmonicznych. Moduł ten składa się z szeregu regulatorów rezonansowych dostrojonych do odpowiednich częstotliwości. Przeanalizowane zostały zarówno odkształcenia symetryczne jak i niesymetryczne a także praca modułu kompensacji w stacjonarnym i wirującym układzie współrzędnych. Na koniec zaprezentowano wybrane przebiegi z badań symulacyjnych i eksperymentalnych.
EN
In this paper the grid current higher harmonic compensation method for two level AC-DC converters in sustainable AC grid is described. The algorithm is based on Direct Power Control with Space Vector Modulator (DPC-SVM), which was extended by additional Higher Harmonics Compensation module. The HHC block is composed of several resonant filters tuned to appropriate frequencies. Both, symmetrical and asymmetrical types of grid currents distortions are analyzed. Operation of the HHC module in stationary αβ coordinates and rotating dq coordinates is discussed. Selected waveforms illustrating operation of the developed algorithm are presented.
EN
The Static Synchronous Compensator (STATCOM a.k.a. SVG) is widely used to regulate dynamic reactive power and to solve dynamic voltage stability problems. Modeling shows that a cascaded STATCOM, which is composed of several cascaded H-bridges, not only has strong coupling characteristics when an LCL filter is added but it is also a non-linear, multivariable system. Therefore, its practical design and application are dicult to implement. In this paper an internal decoupling control algorithm is introduced to provide independent control of the active and reactive currents. Decoupling control algorithms are proposed, and models and simulation of the decoupling are provided. We describe the setting up of a simulation and experiments with a cascaded STATCOM based on combined circuit topology with a multi-field programmable gate array (FPGA), and double-loop control algorithms with a current inner loop, and a capacitor voltage outer loop. To provide control of the current inner loop, proportional-integral (PI) and resonant controllers are used, having the control ability to cancel harmonics while compensating for the reactive power. This paper presents new current-tracing control models that compensate for the fundamental current and eliminate selective harmonics by adopting a d-q synchronous reference frame, and a discrete Fourier transform (DFT). Voltage balance is realized by introducing modulation wave distribution strategies. Furthermore, both simulation and experiments are employed to verify the feasibility and eectiveness of the control strategy.
EN
This paper reports a hybrid power quality compensation scheme based on a combination of dynamic reactive power compensator and a dual active power filters (APF) topology configuration. The parameter designing procedure for reactive compensator and the control strategy for the dual active power filters are presented. The proposed compensation scheme was practically implemented for power quality mitigation project of Shanghai Volkswagen (SVW) Company. The validity and effectiveness of the proposed compensation scheme is verified by the field test results.
PL
W pracy przedstawiono hybrydowy układ kompensacji jakości energii składający sie z dynamicznego kompensatora mocy biernej I podwójnego filtru aktywnego. Przedstawiono procedurę projektową kompensatora mocy biernej i strategię sterowania filtrami aktywnymi. Proponowany system był zastosowany w Shanghai Volkswagen (SVW) Company. Jakość i skuteczność metody została zweryfikowana w warunkach pracy.
PL
Przedstawiono testy modeli układów sterowania jednofazowego falownika PWM, który działa jako rezerwowe (tzw. gwarantowane) zasilanie i jednocześnie umożliwia ładowanie baterii z innego źródła napięcia przemiennego. Jako charakterystyczne warunki obciążenia falownika z filtrem przyjęto odbiorniki z prostownikiem wejściowym, pobierające prąd impulsowy. Przy badaniach symulacyjnych na podstawie napisanych w symulatorze równań modeli sprawdzono kilka typów regulatorów, porównując dla otrzymanych wyników jakość napięcia wyjściowego.
EN
The paper presents simulation results of different control structures suitable for UPS inverters used as emergency AC supply and revers battery loading. The main requirement for the controller is to ensure output voltage wave with proper value of fundamental harmonic and non-distorted as well as limited output current. Obtained records permit for comparison of open loop PI and resonant controllers.