Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!
  • Sesja wygasła!

Znaleziono wyników: 13

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  relay protection
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The implementation of wind power generators into transmission system presents several challenges related to protection schemes, particularly in the areas of relay protection and overcurrent protection. This paper provides an overview in the impact of connecting wind power generators to the transmission system and discusses the key considerations for designing effective relay and overcurrent protection strategies. Intensive analysis was conducted on multiple scenarios involving critical short-circuits, occurring at different nodes within the system, specifically focusing on three-phase current. The situation where the circuit breaker is disconnected after the relay protection was activated, ensuring the protection of high voltage equipment, was also examined. Without proper protection coordination, the selectivity, reliability and sensitivity of the protection system can be compromised. In this paper, a comprehensive protection coordination strategy was developed for the new substation 35/10 kV in Koznica. The use of system simulation techniques, such as employing (Electrical Transient Analyser Program (ETAP) software, can be an effective way to validate the performance and functionality of a system protection. In all simulated scenarios, the analysis identified the circuit breakers that were activated in response to short-circuit faults. This approach ensured the reliability and accuracy of the coordination scheme, thereby enhancing the overall performance and resilience of the system.
2
Content available remote Relay protection settings determination using Its mathematical models
EN
The correct functioning of relay protection (RP) largely determines the stability of electric power systems (EPS). The key point, which in turn determines the behavior of protection in various emergency modes, is their setting. The existing methods and means often do not allow to guarantee the adequacy of protection setting to the real operating conditions, which is confirmed by the statistics of accidents in the EPS. The root cause of this problem is the impossibility using the software tools used in practice for relay settings calculation to reliably reproduce the transient processes in the power system. The EPS simulator – Hybrid Real-Time Power System Simulator (HRTSim), developed by the authors, allows to adequately reproduce the entire spectrum of normal and emergency processes for a power system of any dimension, topology and configuration through the use of detailed three-phase models of all EPS elements. Given this possibility, the task of detailed modeling of relay protection, including instrumental current and voltage transformers, becomes promising. The developed protection modeling tools in combination with the capabilities of the HRTSim allow the development of new methods for determining the relay protection settings. This article presents an algorithm for determining the polygonal and circular tripping characteristics of distance protection, and also presents graphic materials demonstrating the operation of this algorithm. This approach allows to adapt the settings to the real conditions of protection application in the power system, while minimizing the likelihood of their incorrect behavior.
PL
Od prawidłowego działania zabezpieczenia przekaźnikowego (RP) w dużej mierze zależy stabilność układów elektroenergetycznych (EPS). Kluczowym punktem, który z kolei determinuje zachowanie zabezpieczeń w różnych trybach awaryjnych, jest ich ustawienie. Istniejące metody i środki często nie pozwalają na zagwarantowanie adekwatności ustawień zabezpieczeń do rzeczywistych warunków eksploatacji, co potwierdzają statystyki wypadków w SEE. Podstawową przyczyną tego problemu jest niemożność wykorzystania narzędzi programowych stosowanych w praktyce do obliczania ustawień przekaźnika w celu niezawodnego odtworzenia procesów nieustalonych. Opracowany przez autorów symulator EPS - Hybrid Real-Time Power System Simulator (HRTSim) pozwala na adekwatne odwzorowanie całego spektrum procesów normalnych i awaryjnych dla systemu elektroenergetycznego o dowolnym wymiarze, topologii i konfiguracji poprzez zastosowanie szczegółowych trójstopniowych modeli fazowych wszystkich elementów EPS. Biorąc pod uwagę tę możliwość, zadanie szczegółowego modelowania zabezpieczeń przekaźników, w tym przekładników prądowych i napięciowych, staje się obiecujące. Opracowane narzędzia do modelowania zabezpieczeń w połączeniu z możliwościami HRTSim pozwalają na opracowanie nowych metod określania nastaw zabezpieczeń przekaźników. W artykule przedstawiono algorytm wyznaczania wielokątnych i kołowych charakterystyk wyzwalania zabezpieczeń odległościowych, a także przedstawiono materiały graficzne demonstrujące działanie tego algorytmu.
EN
The article presents the digital measuring elements of microprocessor protection, which use combined digital filters to determine the controlled signal during a time equal to a quarter of the period of fundamental frequency. The model of the proposed digital measuring body is implemented in the Matlab-Simulink system. Analysis of the results of computational experiments confirmed the correct functioning of the digital measuring element that had been proposed.
PL
W artykule przedstawiono cyfrowe elementy pomiarowe zabezpieczenia mikroprocesorowego, które wykorzystują połączone filtry cyfrowe do określania kontrolowanego sygnału w czasie równym jednej czwartej okresu częstotliwości podstawowej. Model proponowanego cyfrowego elementu pomiarowego jest zaimplementowany w systemie Matlab-Simulink. Analiza obliczeniowych wyników potwierdziła prawidłowe działanie zaproponowanego cyfrowego elementu pomiarowego.
EN
The main problem preventing the use of digital relay protection mathematical models for real devices setting up is the confidentiality of the information about its internal configuration. This mainly concerns the input circuits (measuring part) of the protection, the components of which introduce the most significant errors. In this case, an arbitrary choice of the configuration may lead to incorrect results. The identification of the internal structure by standard methods, in particular by a real interpolation method, cannot be carried out in practice, due to the need to have input and output signals. In this regard, the purpose of the research was to develop a method of identification according to the time for formation of tripping signal. Identical signals were transmitted to real device and mathematical model of protection. The starting point of the time reference was the moment when the input signal reached a threshold; the final point was the time of tripping command appearance, unlike similar studies, where the time was determined by the closure of the output relay contacts. The research was carried out for 144 different combinations of the measuring part elements: auxiliary converters, analog filters, digital finite impulse response filters. As a result, the combination in which the smallest deviation from the tripping time of the real device was observed in all studied modes was selected as the most ‘optimal’. Performing such comparisons is the main way to make the model closer to real protection.
PL
Analizowano cyfrowe zabezpieczenie przekaźnikowe I jego model matematyczny przy założeniu, że nie jest znana jego struktura wewnętrzna. Zaproponowano metodę identyfikacji bazując na pomiarze czasu między przekroczeniem przez sygnał wejściowy wartości progowe a wyłączeniem.
5
Content available remote Impact of renewables on relay protection operation
EN
The current trend in the development of electric power systems is the integration of renewable energy sources in the form of distributed generation. It was revealed that one of the main reasons inhibiting this process is a change in the EPS operating modes, which in turn has a significant impact on the operation of relay protection and automation and, as a consequence, on their setting. A decrease in sensitivity and a violation of relay protection selectivity in distribution network in the case of integration of wind power generation into EPS have been experimentally proved. An important factor is the capacity and location of the wind power generation facilities connection. In addition, the article analyzes the existing approaches to implement the relay protection of such power systems. As a result, it is theoretically proved the need to develop new methods and means for comprehensive setting up of relay protection and automation, since existing approaches either limit the integration of new installations, or they are difficult to implement, or not flexible enough.
PL
W rozproszonych sieciach w skład których wchodzą odnawialne źródła energii pojawia się problem zmiany warunków pracy przekaźnikowych systemów zabezpieczeń. W artykule analizowano wpływ odnawialnych źródeł energii na systemy zabezpieczeń. Wykazano że istnieje potrzeba opracowania nowych metod zabezpieczeń ponieważ istniejące mają ograniczone możliwości zastosowań.
EN
Calculation of relay protection (RP) settings ensuring its adequate functioning under specific operating conditions is extremely difficult task. The main prerequisite for solving this problem is availability of a detailed analysis of functioning of key elements of RPs schemes in the specific conditions of its operation. That is possible to do with adequate RPs mathematical models and modern EPS simulators. Based on developed by authors approach for detailed RPs simulation the models of the whole circuit of measuring part (MP) of numerical transformer differential protection were developed for different types of auxiliary transformers and low-pass filters. A comparative numerical analysis of its impact on the primary signal processing is carried out, including taking into account the magnetization current transformers. Summarizing, the theoretical and practical studies presented in the article allows formulating requirements for RPs’ detailed mathematical models, which will be used in the further research.
PL
W artykule analizoano warunki prawidłowej pracy cyfrowego zabezpieczenia pracy transformatora. W tym celu opracowano model matematyczny układu zabezpieczającego ze szczególnym uwzględnieniem pracy filtru. Przeprowadzono symulacje dla różnych typów zewnętrznego transformatora i filtru dolnoprzepustowego.
7
Content available remote Sources of independent power supply for protection relay
EN
Nowadays, telemetry and relay protection, which are located directly on the protected element of the electric power system or inside of it are increasingly used in the electric power industry. For its supply, it requires an autonomous source of low power, which has a stabilized DC voltage. Existing devices are unreliable, expensive to manufacture and operate. This work offers power and relay protection and diagnostics with the help of autonomous power sources that can be used in the network with the help of current or voltage transformers, and with the help of an inductive converter placed in the end zone of an electric machine as well.
PL
W pracy nalizowano metody niezależnego zasilania układów przekaźnikowych zabezpieczeń. Układy takie powinny charakteryszować się małym poborem mocy, niezawodnością I niską ceną.
8
Content available remote Wye-connected current transformers simplified model validation in MATLAB-Simulink
EN
This paper presents the wye-connected current transformers (CTs) simplified mathematical model with the initial data based on nominal parameters (nameplate data) of the simulated CT. Designed user-friendly graphical interface allows to specify the CT data (nominal parameters, remanence and burdens) in convenient form. Results of the carried out experiments confirmed the CT model validity.
PL
Niniejszy artykuł przedstawia uproszczony model matematyczny układu przekładników prądowych połączonych w gwiazdę, w którym dane źródłowe oparte zostały o parametry znamionowe (tabliczkę znamionową) symulowanych przekładników. Przyjazny dla użytkownika interfejs graficzny pozwala na określenie danych przekładników prądowych (parametry znamionowe, magnetyzm szczątkowy, obciążenia) w wygodny sposób. Wyniki przeprowadzonych eksperymentów potwierdziły poprawność modelu przekładnika prądowego.
9
Content available remote Validation of mathematical model of differential protection
EN
Comparison of results of mathematical modeling and field tests of a transformer differential protection is presented in this paper. An inrush current mode, external two-phase and three-phase faults are considered. Proposed mathematical model can be used to test differential protection in different modes of transformer operation.
PL
W artykule przedstawiono porównanie wyników badań i rezultatów modelowania matematycznego zabezpieczeń różnicowych transformatorów. Rozpatrzono przypadki prądów rozruchowych oraz zwarć dwufazowych i trójfazowych. Zaproponowany model matematyczny może być używany do testowania zabezpieczeń różnicowych w różnych trybach pracy transformatorów.
PL
Przedstawiono wymagania dotyczące pracy jednostek wytwórczych w KSE (a więc i w UCTE) związane z odchyleniami napięcia i częstotliwości oraz wymagania dla zabezpieczeń podczęstotliwościowych. Przeprowadzono analizę aktualnego stanu w zakresie tych zabezpieczeń zainstalowanych w kraju. Muszą być one skorelowane z innymi elementami automatyki i zabezpieczeń w systemie.
EN
In the paper there are presented requirements concerning the operation of generating units in the NPG (so in the UCTE also) in connection with voltage and frequency deviations and requirements for Underfrequency relay protection installed in this country. They must be correlated with other elements of automatic control and relay protection in the power system.
PL
Produkcja urządzeń pomiarowych to fragment działalności produkcyjnej spółki Energopomiar-Elektryka i część oferty dotyczącej aparatury do sprawdzania urządzeń automatyki elektroenergetycznej. Oferta skierowana jest do służb eksploatujących układy EAZ na obiektach nie objętych szeroką modernizacją, wyposażone w uboższą aparaturę, na których jeszcze przez wiele lat będą przeważały zabezpieczenia elektromechaniczne i statyczne bez jednoznacznego określenia terminu ich wymiany na bardziej nowoczesne.
EN
Production of measurement equipment it Is only a fragment of production activity of the Energopomiar-Elektryka Company and part of an offer concerning equipment for checking the electric power control and relay protection systems. An offer is directed to the service departments maintaining relay protection systems installed in objects not modernised widely, equipped with poorer equipment, where many years yet will predominate electromechanical and static relay protections, without clear established term of their exchange for more modern ones.
PL
Omówiono historię i dzień dzisiejszy firmy, która początkowo w ramach Energopomiaru, a obecnie jako samodzielna, wchodząca w skład Grupy Energopomiar wyspecjalizowała się nie tylko w pracach pomiarowych układów zabezpieczeń bloków i generatorów, ale której pracownicy czynnie uczestniczyli w konstruowaniu, budowie i montażu najbardziej nowoczesnych zabezpieczeń.
EN
There is discussed a history and present day of the company, which has been specialised, initially in the frameworks of the Energopomiar and at present as an independent company included in Energopomiar Group, not only in measurement works concerning the relay systems for generators and power units; its employees actively have taken part in design, production and montage of the most modern relay protection systems.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.