Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 8

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  regulacja prądu
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
In this paper an investigation of voltage control system with P+ current controller for a DC-DC converter is presented. A DC-DC converter based on silicon carbide power devices were used. Synchronous buck topology is used for converter structure. Mathematical model of the converter is presented. The dependence between converter working conditions (i.e. input voltage, load current, switching frequency) and passive LC components is also given. A modified current control method based on P+ structure is considered. Proposed algorithm is compared with a traditional cascade structure based on PI type controllers. Output voltage and coil current dynamics were investigated. Experimental tests results were presented.
PL
W artykule przedstawiono wyniki badań układu regulacji napięcia przetwornicy DC-DC z regulatorem prądu typu P+. Zastosowano przetwornicę DC-DC z łącznikami na bazie węglika krzemu. Przetwornica została wykonana w topologii obniżającej napięcie. Przedstawiony został model matematyczny przetwornicy. Opisano także zależność pomiędzy warunkami pracy przetwornicy (np. napięcie wejściowe, prąd obciążenia, częstotliwość kluczowania) a parametrami elementów pasywnych LC. Przedstawiono propozycję struktury zmodyfikowanego regulatora prądu typu P+. Rozważany algorytm porównano z tradycyjnym algorytmem PI. Przedstawione badanie eksperymentalne dotyczą dynamiki napięcia wyjściowego oraz prądu dławika.
EN
This paper presents an analysis of the properties of pulse width modulator with a single (symmetrical regular sampled PWM) and double (asymmetrical regular sampled PWM) control sampling of the input signal (low-frequency control input wave) in presence of a triangular auxiliary signal. In this paper, a comparison of the characteristics of these modulators used in the control system with a linear proportional controller is presented. The article provides the relations derived for the maximum amplification of regulators for which the control system operates stably. Analysis results have been confirmed by simulation and experimental studies of a commercial active filter installed in an industrial plant.
EN
This paper presents a proposal of a new control method of the switched reluctance motor (SRM) in the low-speed range. The proposed method limits the maximum value of SRM drive supply current. The application of this method results also in improvement of the drive efficiency compared to the classical current control method, so it can be applied to control switched reluctance motors designed to the electric vehicles drive. The method may be effective especially in congested traffic. Nowadays, the urban traffic is characterized by frequent occurrence of traffic jams in which cars move at low speeds. The sources of supply for electric vehicles are mainly electrochemical batteries. Reduction of the maximum value of supply current allows to extend the service life of batteries and improvement of the drive efficiency extends the vehicle range.
4
Content available remote Traction group drive fed by an inverter with reduced switching frequency
EN
The article presents a concept of the control algorithm for the traction group drive consisting of two cage induction motors supplied from the common inverter, which could operate with reduced switching frequency and the result of its testing on a physical model in the laboratory. These tests were conducted on a specially constructed bench, simulating in laboratory scale the true nature of phenomena accompanying the passage of the wheels through the rail crossing, associated with an abrupt change in the angular velocity of the wheels belonging to the same group drive.
PL
W artykule przedstawiono koncepcję algorytmu sterowania dla grupowego napędu trakcyjnego składającego się z dwóch klatkowych silników indukcyjnych zasilanych ze wspólnego falownika, mogącego pracować z obniżoną częstotliwością przełączeń i wyniki badań jego fizycznego modelu laboratoryjnego. Badania przeprowadzono na specjalnie zbudowanym stanowisku pozwalającym odtworzyć w warunkach laboratoryjnych rzeczywisty charakter zjawisk towarzyszących przejazdowi kół pojazdu szynowego przez połączenia torowisk, wiążących się z raptowną zmianą prędkości kątowej kół należących do tego samego napędu grupowego.
PL
W artykule przedstawiono możliwości zastosowania predykcyjnego algorytmu regulacji prądu w trójfazowym przekształtniku AC/DC, pracującym jako trójgałęziowy filtr aktywny. Algorytm bazuje na pryncypiach metody DPC (Direct Power Control). Zastosowanie w nieliniowym algorytmie modulacji wektorowej umożliwia minimalizację uchybu wektora prądu w pojedynczym okresie próbkowania procesora, zmniejszenie tętnień prądu sieciowego, zapewnienia stałą częstotliwość przełączeń przy bardzo dobrych właściwościach dynamicznych układu, co umożliwia w prosty sposób wyeliminowanie harmonicznych związanych z przełączaniem tranzystorów przy użyciu rezonansowego filtru LC. Przedstawiono wyniki badań symulacyjnych, potwierdzające poprawność przeprowadzonej analizy.
EN
In This article a new, predictive control method of Active Power Filter are presented. The method is based on the Direct Power Control algorithm and the current error vector minimization criteria. This non-linear method with vector modulation ensures constant switching frequency and grid current error vector minimization without deterioration of very good dynamic properties. Constant switching frequency provides a simple way to eliminate (using LC passive filter) the current higher harmonics associated with switching transistors. The analysis correctness is acknowledged by the simulation investigation results.
PL
W pracy przedstawiono układ automatycznej regulacji prądu w uzwojeniach siłownika łożyska magnetycznego z regulatorem PI. Nastawy regulatora przyjęto dla różnych czasów regulacji tR. Porównano przebiegi przejściowe układu zamodelowanego w pakiecie Matlab z układem rzeczywistym.
EN
DC ferromagnetic actuators enter generally into the composition of electric systems, used e.g. in electric apparatus, numerically controlled machines, in various automatons, robots, as well as in nuclear engineering where such kind of equipment, often combined with permanent magnets constitute important elements, of control and safety protection of nuclear reactors. In many applications they should have flat static characteristics, ensuring practically constant force, independently of armature position with respect to the stationary parts of the servo. The paper considers two possibilities of achieving flat characteristics by: a) a special design of the magnetic core, ensuring its constant magnetic resistance at any armature position, and b) excitation current control ensuring a constant magnetic flux in the magnetic core of the servo. In the first case the desired result can be achieved by into the suitable slanting of armature or by placing nonmagnetic inserts moving parts because the excitation current will then remain constant without any control. In the second case the actuator is simple and the practically flat characteristic is achieved by controlling the current according to the instantaneous position of the armature. However, this method requires a highly precise sensor and a sufficiently fast control circuitry. The device can be properly designed only in the way of mathematical and computer-aided modelling. The existing professional programs are usually of no use for solving the problem fully, thus it becomes often necessary to combine a suitable professional tool with a user procedure developed especially for a determined class of tasks. On the basis of a numerical analysis of the problem the following conclusions can be drawn: ź Suitable design modifications of selected parts of the actuator can ensure accurately or approximately flat static characteristic. ź A good method is slanting the front part of the armature. The higher the slanting the flatter is the static characteristic. However this method may be limited by various technological considerations. ź Building the armature of several magnetic and nonmagnetic parts may lead to relatively flat characteristics however there appeare here often sharp minima and maxima which cannot be accepted in some applications. ź A perfectly flat characteristic can be achieved by direct control of the excitation current, depending on the position of the device moving parts. However this method requires a very precise sensor and an adequately fast control system.
PL
Ferromagnetyczne siłowniki (aktuatory) prądu stałego wchodzą powszechnie w skład systemów silnoprądowych, stosowanych np. w aparatach elektrycznych, maszynach sterowanych numerycznie, w różnych automatach, robotach, a także w inżynierii jądrowej, gdzie tego rodzaju przyrządy, często w kombinacji z magnesami trwałymi, są ważnymi elementami regulacji i zabezpieczeń reaktorów jądrowych. W wielu zastosowaniach powinny mieć płaskie charakterystyki statyczne, zapewniając praktycznie stałą siłę, niezależnie od położenia twornika względem części nieruchomych siłownika. W artykule rozważono dwie możliwości uzyskania płaskich charakterystyk poprzez: a) specjalną konstrukcję magnetowodu, zapewniającą stałą jego rezystancję magnetyczną w każdej pozycji twornika, oraz b) regulację prądu wzbudzenia, zapewniając stały strumień magnetyczny w magnetowodzie siłownika. W pierwszym przypadku pożądany wynik można osiągnąć poprzez odpowiednie skoszenie twornika lub umieszczenie niemagnetycznej wkładki w częściach ruchomych; prąd wzbudzenia będzie miał stałą wartość, bez regulacji. W drugim przypadku siłownik jest prosty, a praktycznie stałą charakterystykę osiąga się regulując prąd stosownie do chwilowego położenia twornika. Ten sposób wymaga jednakże wysoce dokładnego czujnika i dostatecznie szybkiego obwodu sterowania. Prawidłowo można zaprojektować przyrząd jedynie drogą matematycznego i komputerowego modelowania. Istniejące programy profesjonalne zazwyczaj są nieprzydatne do pełnego rozwiązania problemu, zachodzi zatem często potrzeba kombinacji odpowiedniego narzędzia profesjonalnego z procedurą użytkownika opracowaną specjalnie dla określonej klasy zadań. Na podstawie analizy numerycznej problemu można wyciągnąć następujące wnioski: ź Odpowiednie modyfikacje konstrukcyjne wybranych części siłownika mogą zaowocować dokładnie bądź przybliżeniu płaską charakterystyką statyczną. ź Dobrą metodą jest skoszenie czoła twornika. Im większy jest stopień skoszenia, tym bardziej płaska będzie charakterystyka statyczna. Sposób ten może być ograniczony jednakże różnymi względami technologicznymi. ź Budowa twornika z kilku części magnetycznych i niemagnetycznych może prowadzić do względnie płaskich charakterystyk, jednak częstokroć występują tu ostre minima i maksima, co jest nie do przyjęcia w niektórych zastosowaniach. ź Doskonale płaska charakterystykę statyczna uzyskuje się poprzez bezpośrednie sterowanie prądu wzbudzenia, zależnie od położenia części ruchomych przyrządu. Ten sposób wymaga jednakże bardzo dokładnego czujnika i odpowiednio szybkiego układu sterowania.
PL
Przekształtnik Ac/DC może spełniać rolę zasilacza pobierającego z sieci prąd sinusoidalny o współczynniku mocy równym jeden. w artykule opisano warunek, jaki muszą spełniać: napięcie sieci zasilającej, napięcie w obwodzie pośredniczącym, indukcyjności sprzęgajace sieć z przekształtnikiem oraz prądy pobierane z sieci, aby możliwe było odtwarzanie zadanych prądów. Przedstawiono możliwość wykorzystania wyznaczonego warunku do określenia indukcyjności dławika umożliwiającej kształtowanie prądu w zadanych warunkach.
EN
An Ac/DC converter can operate as a power source, which draws a sinusoidal line current at unity power factor. In this mode of operation the sinusoidal waveforms of the current should be created. The condition, which should be satisfied by the source voltage, DC voltage, input inductance and input currents, to re-create the set current are described in the paper. This condition could be used to calculate the maximal input inductance for which the input current may follow up sinusoidal waveform. The results of the computer simulations confirming presented investigations are presented in the paper.
first rewind previous Strona / 1 next fast forward last