Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników
Powiadomienia systemowe
  • Sesja wygasła!

Znaleziono wyników: 6

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  reflektometria czasowa
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
The article presents the description of measurement methodology of moisture transport in unsaturated porous materials using Time Domain Reflectometry (TDR) technique on the example of measurement of capillary uptake phenomenon in the sample of autoclaved aerated concrete (AAC). In the paper there are presented basic principles of the TDR method as a technique applied in metrology, its potential for measurement of moisture in porous materials like soils and porous building materials. Second part of the article presents the experiment of capillary rise process in the sample of AAC. Within the experiment moisture content was monitored in the sample exposed on water influence. Monitoring was conducted using TDR FP/mts probes. Preparation of the measuring setup was presented in detail. The TDR readouts post-processing, graphical presentations of the obtained results, short discussion and comparison of TDR readouts to gravimetric measurement were also presented.
PL
W artykule przedstawiono opis metodyki pomiaru transportu wilgoci w nienasyconych porowatych materiałach przy wykorzystaniu techniki Time Domain Reflectometry (TDR) na przykładzie pomiarów zjawiska podciągania kapilarnego przez próbkę autoklawizowanego betonu komórkowego. Zaprezentowano podstawowe informacje na temat metody TDR jako techniki stosowanej w metrologii. Omówiono jej potencjał do pomiarów wilgoci w takich ośrodkach porowatych, jak gleby i porowate materiały budowlane. Druga część artykułu przedstawia eksperyment podciągania kapilarnego przez próbkę autoklawizowanego betonu komórkowego. W trakcie trwania eksperymentu monitorowano zmiany wilgotności w próbce wystawionej na oddziaływaniewody. Monitoring realizowano za pomocą sond TDR FP/mts. Rozdział „Materials and Methods” przedstawia szczegółowo przygotowanie stanowiska pomiarowego. W rozdziale „Results” podano odczyty miernika TDR przeliczone na wilgotność oraz zaprezentowano uzyskane wyniki w postaci graficznej. Zawarto w nim również krótką dyskusję wyników i porównanie odczytów TDR z pomiarami grawimetrycznymi.
PL
Artykuł prezentuje nowy sposób podejścia do realizacji tanich układów reflektometrii czasowej. Istotą rozwiązania jest zastosowanie cyfrowo-analogowego sposobu wytwarzania opóźnień pomiędzy sygnałem pobudzającym, a momentem pobrania próbki i umieszczenie analogowego układu opóźniającego w torze generacji sygnału pobudzającego. W artykule opisano ogólnie algorytm generacji wymaganych sygnałów sterujących i przedstawiono konkretne parametry sygnałów praktycznie zrealizowanego układu.
EN
The paper presents a novel solution of low cost TDR equipment. The main idea is application of mixed (digital and analog) control of excitation-sampling time and placing analog delay circuit in excitation branch of the equipment. The paper describes a general algorithm of required signal generation as well as parameters of a real equipment.
PL
W artykule przedstawiono urządzenie przeznaczone do impulsowych pomiarów symetrycznych linii transmisyjnych metodą reflektometrii czasowej. Skoncentrowano się na układach nadajnika (wraz z generatorem opóźnienia niezbędnym do realizacji pomiarów metodą stroboskopową) i odbiornika sygnału symetrycznego. Przedstawiono również sposób sterowania urządzeniem poprzez komputer i położono tu szczególny nacisk na efektywność transmisji wyników pomiaru. Przedstawione urządzenie zostało zaprojektowane, wykonane i przetestowane podczas badania linii telefonicznych.
EN
The paper presents computer - controlled device for pulse testing of symmetrical transmission lines using time - domain reflectometry (TDR) technique. Most attention was paid to transmitter (including delay generator needed for Stroboscope technique implementation) and receiver circuits. Software necessary for device control was also presented, focusing on key problem of data transmission efficiency.
4
Content available remote Time domain reflectometry module for DSL analyzer
EN
The paper present a time domain reflectometry module designed as a part of an analyzer of DLS transmission lines. Small size, programmable TDR module (to be included in the hand-belt, battery-operated line analyzer) was designed, constructed and tested in the laboratory, proving its usefulness for detecting lines imperfections. The paper illustrates the principle of operation of the TDR units, its basic building blocks and the software environment created for device testing.
5
Content available remote TDR-based examination of DSL transmission line
EN
The paper presents results of TDR-based DSL line characterization. Measurement and computer analysis results are included for two distinct modes of TDR system: step and pulse. Measurement results emphasize the influence of a skin effect, which significantly limits measurement system resolution and accuracy. Results of numerous simulations allow for estimation of the dependence of reflected signal parameters on testing pulse width and/or length of line being examined.
6
Content available Polowy system monitorowania wilgotności gleby
PL
Znajomość parametrów fizyko-chemicznych gleby takich jak wilgotność, zasolenie oraz temperatura umożliwia dokonanie analiz zasobów wodnych, zawartości składników odżywczych roślin i ich przemieszczania w profilu glebowym oraz ocenę pojemności cieplnej gleby. Monitoring wilgotności gleby w obecnym czasie staje się bardzo poważnym zagadnieniem w świetle zmniejszania się zasobów wodnych. W czasie, gdy coraz częściej mamy do czynienia z anomaliami pogodowymi związanymi z nadmiarem wody albo jej długotrwałym brakiem, monitorowanie jej zawartości w wierzchnich warstwach gleby i profilu glebowym zaczyna odgrywać decydującą rolę umożliwiającą modelowanie oraz weryfikację modeli i dostarczając informacji potrzebnych do interpretacji zdjęć satelitarnych. W pracy przedstawiono polowy system monitoringu wilgotności, elektrycznej konduktywności oraz temperatury gleby mierzonych za pomocą zintegrowanej sondy reflektometrycznej. Pomiary przenikalności dielektrycznej realizowane są w częstotliwości z zakresu kilkuset kiloherców, dzięki czemu unika się wpływu zasolenia gleby. Obecnie prace nad rozwojem systemu koncentrują się na ulepszaniu istniejących czujników przez wprowadzenie możliwości identyfikacji, przetwarzania sygnału mierzonego i zwiększenia możliwości obliczeniowych w bezpośredniej bliskości obiektu mierzonego, jak również wyposażeniem tych czujników w moduły komunikacji bezprzewodowej na krótkż odległość.
EN
Knowledge of the soil physico-chemical parameters, such as moisture, salinity and temperature enables evaluating water reserves, plant nutrients and their movement in the soil profile as well as soil heat capacity. Monitoring of soil moisture becomes a vital issue at the moment, when weather anomalies connected with the abundance or shortages of water are reported. The monitoring of the amount of water content in the upper soil layer together with other soil parameters, that do not change rapidly in time, allows modelling and validation of existing models of mass and energy transport in the soil and it is necessary for interpretation of satellite data. The study presents a field monitoring system of soil moisture, electrical conductivity (salinity) and temperature measured by an integrated reflectometric probe. This probe measures dielectric permittivity of surrounding medium in the frequency of hundreds of megahertz and therefore the results are not influenced by soil salinity. At present work on the system concentrates on improving existing sensors by introducing identification, conversion and computation facilities to the measured object as close as possible, as well as providing the sensors with a short range wireless communication.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.