The paper presents formulas which can be used to determine steam condensation pressure in a power plant condenser in off-design conditions. The mathematical model provided in the paper makes it possible to calculate the performance of the condenser in terms of condensing steam pressure, cooling water temperature at the condenser outlet, and condenser effectiveness under variable load conditions as a function of three input properties: the temperature and the mass flow rate of cooling water at the condenser inlet and the mass flow rate of steam. The mathematical model takes into account values of properties occurring in reference conditions but it contains no constant coefficients which would have to be established based on data from technical specifications of a condenser or measurement data. Since there are no such constant coefficients, the model of the steam condenser proposed in the paper is universally applicable. The proposed equations were checked against warranty measurements made in the condenser and measurement data gathered during the operation of a 200 MW steam power unit. Based on the analysis, a conclusion may be drawn that the proposed means of determining pressure in a condenser in off-design conditions reflects the condenser performance with sufficient accuracy. This model can be used in optimization and diagnostic analyses of the performance of a power generation unit.
PL
Efektywność skraplacza jest funkcją współczynnika przenikania ciepła, powierzchni wymiany ciepła i strumienia pojemności cieplnej czynnika ogrzewanego. W literaturze można też znaleźć inne aproksymacyjne zależności, które są funkcją parametrów wlotowych i zawierają stałe współczynniki, które trzeba określic na podstawie danych pomiarowych. W artykule przedstawiono zależność na efektywność skraplacza w funkcji parametrów wlotowych i odpowiadających im parametrów dla stanu odniesienia. Proponowana zależność ma prostą postać i zawiera tylko parametry wejściowe i parametry w stanie odniesienia. Z analizy proponowanej zależności wynika, że efektywność skraplacza w otoczeniu parametrów odniesienia można przyjąć jako stałą, równą efektywności skraplacza dla warunków odniesienia. Przyjęcie stałej wartości efektywności skraplacza pozwala na przykład w prosty sposób określic temperaturę wylotową wody chłodzącej z zadowalającą dokładnością dla zmiennych warunków pracy dla szerokiego zakresu zmian parametrów wejściowych. Słuszność przyjętego założenia sprawdzono na podstawie danych uzyskanych z symulatora skraplacza dla bloku 200 MW i danych pomiarowych.
EN
Condenser effectiveness is a function of an overall heat transfer coefficient, heat transfer area, and the heat capacity rate of the heated fluid. In the literature, other approximate equations can be found being functions of inlet parameters and containing constant coefficients which have to be established based on measurement data. The present paper provides an equation for the condenser effectiveness being a function of parameters at the condenser inlet and ones that correspond to the inlet parameters and are relevant in a reference state. The proposed equation has simple form and contains only the inlet and reference parameters. An analysis of the proposed equation shows that the condenser effectiveness in the neighborhood of the reference parameters can be considered constant and equal to the condenser effectiveness in reference conditions. By using a constant value of the condenser effectiveness one can, for instance, easily determine cooling water outlet temperature with satisfactory accuracy for variable operating conditions and a wide range of changes in inlet parameters. This assumption was verified to be true based on data obtained from a simulator of a 200-MW unit condenser and on measurement data.
PL
W pracy przedstawiono opracowaną elektroniczną bazę danych o wybranych okrętowych tłokowych silnikach spalinowych dla potrzeb diagnostyki. Baza danych została wykonana dla jednostek pływających największego krajowego armatora. Służy ona do porównania mierzonych parametrów diagnozowanych silników w warunkach eksploatacji z parametrami odniesienia. Stan odniesienia to stan silnika zdatnego, który był po jego wytworzeniu, potwierdzony w czasie prób odbiorczych. Aby można było racjonalnie wykorzystać potrzebne dane, zgromadzono je i skatalogowano, co pozwoliło na proste wyszukiwanie. W tym celu sporządzono bazę danych w oparciu o program, wchodzący w skład pakietu biurowego Microsoft Office. W bazie danych rozwiązano wyszukiwanie danych według rodzaju statku. W polach wyświetlanych znajdują się takie opisy jak: rok i miejsce budowy, parametry statku, bandera itp. Dla każdego statku opracowano formularze silniki główne i pomocnicze, które pozwolą na łatwe i szybkie sprawdzenie potrzebnych parametrów podczas eksploatacji danego silnika. Baza zawiera wybrane parametry silników napędu głównego i pomocniczych oraz charakterystyki wzorcowe, które ułatwią ustalenie diagnozy, prognozy i genezy.
EN
The paper has developed the elaborated an electronic database of selected marine piston combustion engines for diagnostic. The database was constructed for the largest crafttion of the national shipowners. It serves to relate the measured parameters of a target engine operating conditions for the reference parameters. State of reference is a state capable engine, which was after its production, confirmed at the time of acceptance tests. To be able to reasonably use the most needed data, collected and cataloged them, allowing the simple search. For this purpose, drawn up a database based on the program, part of the Microsoft Office suite. The database search resolved data by type of vessel. The fields displayed include such names as year and place of construction, the parameters of the ship, flag, etc. For each vessel forms were developed main and auxiliary engines, which allow for easy and quick check of the necessary parameters during operation of the engine. The database contains some parameters of the main propulsion engines and auxiliary and characterization of reference to help determine the diagnosis, prognosis and genesis.