Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 10

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  rectifiers
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
This paper presents an improved Virtual Flux-based Direct Power Control (VFDPC) applied for a three-phase pulse width modulation rectifier. The proposed control approach incorporates an enhanced Virtual Flux estimator made up of a cascade seconddegree low-pass filter. This latter guarantees the attenuation of the highest harmonics. The introduced control concept presented in this paper has interesting features such as reducing the current harmonics distortion. In other words, it ensures that the input current drawn from the power supply is perfectly sinusoidal whatever the state of the network voltage. The proposed method also allows to maintain the DC side capacitor voltage at the required level and assure that the input current is in phase with the respective voltage to satisfy the unity power factor function. The results obtained from the numerical simulation have proved the effectiveness of the proposed method for disturbed grid voltage and system parameters variation.
EN
This paper deals with real-time (RT) simulators applied in power electronic applications and implemented in a real inverter. The process of preparing and starting up an active rectifier prototype (with an active filter function), using the real-time OPAL RT simulator is given. The control system of the converter and the results of simulation using the Matlab/Simulink suite are discussed.
EN
The article presents the current state and development trends of electrical drives, with particular emphasis on modern control structures and safety systems of various types of electrical machines. Special attention was paid to the needs of industrial drive systems and a possibility of practical implementation of complex control algorithms. Development perspectives of electrical drives are discussed from the perspective of new trends in control, power electronics and electrical machines, with consideration for systems robust to faults of drive system elements.
EN
Maximum values of possible earth fault currents in low voltage unearthed AC networks supplying DC circuits through diode rectifiers are critical for evaluation of possible electric shock and fire hazards caused by insulation condition deterioration. A method for analytical determination of time functions of earth fault parameters, i.e. wire-to-earth voltages and currents is presented in the paper. Application of two characteristic parameters i.e. the phase voltage mean value and the phase voltages zero sequence component to insulation condition evaluation is discussed. A new method exploiting the phase voltages mean value for insulation resistance monitoring is presented.
PL
Maksymalne wartości prądów zwarć z ziemią w sieciach izolowanych AC zasilających obwody DC przez prostowniki diodowe decydują o ewentualnych ryzykach porażenia osób, pożaru i wybuchu. W artykule przedstawiono metodę analitycznego wyznaczania przebiegów czasowych parametrów ziemnozwarciowych tj. napięć i prądów doziemnych; zagadnienie to było dotychczas pomijane w dostępnej literaturze. Wyznaczono zależności dla charakterystycznego parametru układów AC/DC IT, którym jest wartość średnia napięć fazowych strony AC. Omówiono przydatność tej wielkości dla kontroli izolacji tych sieci oraz lokalizacji doziemień. W oparciu o najczęstsze w praktyce przypadki pokazano, że składowa zerowa napięć fazowych spełnia funkcję sygnalizacji pogorszenia stanu izolacji praktycznie jedynie dla strony AC (rys. 4). Przy uszkodzeniach izolacji po stronie DC napięcie tej składowej w nieznacznym stopniu zależy od rezystancji zwarcia doziemnego. Z użyciem wartości zastępczej rezystancji izolacji całego układu AC/DC IT oszacowano maksymalny poziom prądu upływu decydujący o bezpieczeństwie porażeniowym i pożarowym sieci. W artykule zaproponowano nową metodę wyznaczania wartości zastępczej rezystancji izolacji całego układu. Procedura z użyciem dodatkowego rezystora testowego obejmuje pomiary wartości średniej napięć fazowych, na bazie których oblicza się wartość szukanego parametru. Oprócz prostoty i braku wrażliwości na pojemności doziemne metoda wyróżnia się uniwersalnością, gdyż uwzględnia upływności izolacji całej sieci AC/DC IT.
5
Content available remote Neuronowy system diagnostyczny dla układów prostowniczych
PL
W artykule zaprezentowano uniwersalny bezinwazyjny system diagnozowania różnych stanów pracy układów prostowniczych z zastosowaniem sztucznych sieci neuronowych. Zaproponowana koncepcja wykorzystuje modele matematyczne badanych obiektów i umożliwia dostrojenie systemu diagnostycznego do optymalnego funkcjonowania. Zastosowany model matematyczny został opracowany w oparciu o teorię obwodów elektrycznych z wykorzystaniem dwustanowej zmiennej logicznej. Charakteryzuje się on dokładnością, która jest wystarczająca jako analizator stanów w układach diagnostycznych, a uzyskane przebiegi z modelu odzwierciedlają charakter badanego obiektu. Wybór architektury sztucznych sieci neuronowych (BP, LVQ) jako analizatora wiąże się z wyborem metody preprocesingu danych i etapem strojenia systemu. Przełączenie z trybu dostrojenia do pracy on-line opiera się na przekierowaniu strumienia danych na pomiary rzeczywiste.
EN
The paper presents a universal non-invasive diagnostic system work in different states of rectifier circuits using artificial neural networks. The proposed approach uses mathematical models of object and allows to fine-tune the diagnostic system for optimal functioning. The applied mathematical model was developed based on the theory of electrical circuits using two state of variable boolean. It is characterized by an accuracy that is sufficient as a state analyzer in diagnostic systems, and the course of signals is obtained from the model reflect the nature of the test object. The choice of architecture of artificial neural networks (BP, LVQ) as the analyzer is connected with the choice of methods for preprocessing data and tuning the system. Switching from tune to work on-line is based on redirecting the data stream to the actual measurements.
PL
W artykule opisano możliwość wykorzystania programu multiSim do analizy uszkodzeń układów prostowniczych stosowanych w przemyśle rolno-spożywczym. Opisano zaprojektowane w programie multiSim typowe układy prostowników trójfazowych i jednofazowych oraz przedstawiono wygenerowane w tym programie przebiegi wyjściowe przy braku uszkodzeń elementów prostowniczych jak i przy uwzględnieniu typowych ich uszkodzeń. Wyniki symulacyjne zostały porównane z przebiegami otrzymanymi w rzeczywistych układach. Badania potwierdziły przydatność stosowania programu symulacyjnego, ale również wykazały ograniczenia w jego wykorzystaniu.
EN
The article describes the possibility of using the multiSlim program for analyzing damages within rectifiers used in the agricultural and food industry. Typical three-phase and one-phase rectifiers designed with the multiSlim program were described as well as output generated by this program either with no damage of the rectifier elements or with typical damage included was presented. The simulation results were compared to the courses obtained in actual systems. The tests confirmed that the simulation program is useful but also indicated limitations of its use.
7
Content available remote Układy elektromagnetyczne prostowników wielopulsowych
PL
Technika wielopulsowa stosowana w przekształtnikach AC/DC dużej mocy umożliwia uzyskanie małego współczynnika odkształcenia prądu pobieranego z sieci zasilającej. W artykule są omówione układy AC/DC12- i 18-pulsowe z zastosowaniem różnych topologii autotransformatorów i trójfazowych dławików sprzężonych. Podana jest analiza prostowników z dławikami sprzężonymi przy wykorzystaniu metody wektorów przestrzennych. Zamieszczono niektóre wyniki badań wybranych układów przekształtników.
EN
The multipulse method used in high power AC/DC converters enables to acquire Iow value of the distortion factor of the current drawn from the line system. The article presents 12- and 18-pulse AC/DC circuits with various autotransformer connections and three-phased coupled reactors. Applying the space vector method, it analyses rectifiers with coupled reactors. Some research results of chosen converter circuits are included.
PL
Istotność problemu jakości mocy elektrycznej wynika z przyczyn natury ekonomicznej. Jakość mocy elektrycznej wyrażana jest poprzez zespół współczyników, takich jak:wspłczynnik THD, współczynnik mocy, współczynnik mocy przesunięcia. Znormalizowane wartości tych współczynników są bardzo wymagające. Analizy przeprowadzone w wielu jednostkach naukowych na świecie wykazały, że jedynie systemy energoelektroniczne pozwalają spełnić te wymagania. Omawiany problem jest szczególnie związany z układami prostowniczymi. Klasyczne prostowniki diodowe i tyrystorowe, szeroko stosowane w Polsce, posiadają współczynnik THD wynoszący około 30%, podczas gdy planowanenormy wymagają, aby wartość tego współczynnika była mniejsa od 5%. Powoduje to, że problem jakości mocy elektrycznej pobieranej przez prostownika jest ważny i aktualny.
EN
The importance of the problem of electrical power quality arises from the economical reasons. The electrical power quality is expressed by set of coefficients like the total harmonic distortion, the total power factor, the power displacement factor. The normalised values of these factors are very demanding. From the analyses carried out by many scientific centres it is concluded that only the active power electronics systems can meet these demands. The presented problem is especially concerned with rectification systems. The classical diode and thyristor rectifier systems, widely applied in Poland, have the current's total harmonics distortion ratio about 30% while the planned normalised values is about 55. It makes the problem of improving of the electrical power quality of the rectifier's systems be common and important.
EN
The importance of the problem of electrical power quality arises from the economical reasons. The electrical power quality is expressed by the set of coefficients like the total harmonic distortion, the total power factor, the power displacement factor. The normalised values of these factors are very demanding. From the analyses carried out by many scientific centres it is concluded that only the active power electronics systems can meet these demands. The presented problem is especially concerned with rectification systems. The classical diode and thyristor rectifier systems, widely applied in Poland, have the current total harmonics distortion ratio about 30% while the planned normalised value is about 5 %. It makes the problem of improłing of the electrical power quality of the rectifier's systems be common and important
PL
Istotność problemu jakości mocy elektrycznej wynika z przyczyn natury ekonomicznej. Jakość mocy elektrycznej wyrażana jest poprzez zespól współczynników takich jak współczynnik THD, współczynnik mocy, współczynnik mocy przesunięcia. Znormalizowane wartości tych współczynników są bardzo wymagające. Analizy przeprowadzone w wielu jednostkach naukowych na świecie wykazały, że jedynie systemy energoelektroniczne pozwalaj ą spełnić te wymagania. Omawiany problem jest szczególnie związany z układami prostowniczymi. Klasyczne prostowniki diodowe i tyrystorowe, szeroko stosowane w Polsce, posiadaj ą współczynnik THD wynoszący około 30% podczas gdy planowane normy wymagają aby wartość tego współczynnika była mniejsza od 5%. Powoduje to, że problem jakości mocy elektrycznej pobieranej przez prostowniki jest ważny i aktualny.
EN
The subject of this paper is theoretical and simulation investigation of modified diode rectifier with improved power factor assembled according to proposition presented in [l], The modified diode rectifier with additional power electronic valves used for modelling of multilevel voltage at the input of the diode rectifier is analysed. The mathematical model of the analysed rectifier system is presented. The control characteristics of the rectifier system are derived, constrains involved by the multilevel voltage generation scheme are pointed. The main conclusion derived from the perfomed analysis is that the modified rectifier system allow to obtain significant reduction of the THD(i) factor but only in the case of the nominal load.
PL
Tematem prezentowanej pracy są badania teoretyczne i symulacyjne prostownika o poprawionym współczynniku mocy, zrealizowanego według pomysłu przedstawionego w pracy |1]. W pracy przedstawiono szczegółową analizę zmodyfikowanego układu trójfazowego mostka diodowego, w którym zastosowano dodatkowe łączniki do kształtowania przebiegu czasowego napięcia na zaciskach wejściowych mostka diodowego. Zaprezentowany został model matematyczny układu oraz wyniki badań symulacyjnych. Wyprowadzono charakterystyki sterowania układu i wynikające z metody kształtowania wejściowego napięcia schodkowego na zaciskach mostka diodowego ograniczenia zakresu sterowania. Wykazano, że układ umożliwia uzyskanie istotnego zmniejszenia THD(i), jednakże tylko w warunkach obciążenia znamionowego.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.