Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 2

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  reactive power controller
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Compensation of reactive power is necessary for reduction the effects caused by the inductive load. To achieve these issues, the utilize power electronics devices are used to control the reactive power flow using static synchronous compensator STATCOM. It is a shunt connected FACTS compensator that provide/withdraw reactive power. This approach is implemented to enhance voltage drop in distribution grid. In this paper, an adaptive neuro-fuzzy logic controller based STATCOM is proposed to regulate the bus voltages of IEEE 9 bus 33kV distribution grid. Method of dq transformation is used for reactive power calculation due to its high accuracy and simple application. Adaptive controller designed based on Sugeno type fuzzy logic rules show that the compensator increases bus voltage about 19%, with damping oscillation during step change compared with the conventional PI controllers.
PL
Kompensacja mocy biernej jest konieczna do zmniejszenia skutków wywołanych obciążeniem indukcyjnym. Aby osiągnąć te problemy, wykorzystuje się urządzenia energoelektroniczne do sterowania przepływem mocy biernej za pomocą statycznego kompensatora synchronicznego STATCOM. Jest to kompensator FACTS połączony z bocznikiem, który dostarcza/odbiera moc bierną. Takie podejście jest wdrażane w celu zwiększenia spadku napięcia w sieci dystrybucyjnej. W niniejszym artykule zaproponowano adaptacyjny sterownik logiki neurorozmytej oparty na STATCOM do regulacji napięć magistrali sieci dystrybucyjnej IEEE 9 33 kV. Metoda transformacji dq jest wykorzystywana do obliczania mocy biernej ze względu na jej dużą dokładność i prostą aplikację. Sterownik adaptacyjny zaprojektowany w oparciu o zasady logiki rozmytej typu Sugeno pokazuje, że kompensator zwiększa napięcie szyny o około 19%, z tłumieniem drgań podczas zmiany skoku w porównaniu z konwencjonalnymi sterownikami PI.
EN
This article presents a excitation power supply unit for synchronous motors with a microprocessor control system. The theoretical basics of reactive power regulation with a synchronous motor and influence of load on the permissible operating range are discussed. The possibilities of controlling the motor by a microprocessor system in the developed device during asynchronous start-up and synchronous operation are presented. The ability to monitor and record the status of the drive, which allows us to analyze the sequence of events in case of emergencies, is also presented. Dedicated software for diagnostic and service operation is demonstrated. The selected diagnostic functionality is also discussed.
PL
W artykule przedstawiono blok zasilania wzbudzenia silników synchronicznych z mikroprocesorowym układem sterowania. Omówiono podstawy teoretyczne regulacji mocy biernej za pomocą silnika synchronicznego oraz wpływ obciążenia na dopuszczalny obszar pracy. Przedstawiono możliwości sterowania silnikiem przez system mikroprocesorowy opracowanego urządzenia podczas rozruchu asynchronicznego i pracy synchronicznej. Zaprezentowano możliwości monitorowania i rejestracji stanu pracy napędu pozwalające na analizę sekwencji zdarzeń w przypadku wystąpienia stanów awaryjnych. Przedstawiono dedykowane oprogramowanie diagnostyczno-serwisowe. Omówiono wybrane funkcje diagnostyczne.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.