Content available remote Active and reactive power control in a three-phase photovoltaic inverter
EN
In most nations, grid-connected buildings with solar systems are expanding. Several sites in the system network have high PV penetration. The irregular nature of PV installations could affect the distribution network. Instead of expensive grid installations, PV systems can employ a voltage source inverter to utilize reactive power. The major objective is to inject and control 100 kW of three-phase, two-stage solar PV power into the grid in order to maintain a constant voltage independent of variations in solar radiation and to keep the current's THD within international standards. PV system implementation depends on practical system concerns. Reactive power control and inverter control are created. The network variable the whole system shows good usage of reactive power. The suggested 100 KW PV system in this study achieves reactive power regulation and sinusoidal three-phase output currents. Using MATLAB 2021b and Simulink software, the recommended system's effectiveness was elucidated and its viability was demonstrated. The results demonstrated the effectiveness of the recommended design and modelling.
PL
W większości krajów rozbudowuje się budynki podłączone do sieci z systemami słonecznymi. Kilka lokalizacji w sieci systemowej ma wysoką penetrację PV. Nieregularny charakter instalacji fotowoltaicznych może mieć wpływ na sieć dystrybucyjną. Zamiast drogich instalacji sieciowych, systemy fotowoltaiczne mogą wykorzystywać falownik źródła napięcia do wykorzystania mocy biernej. Głównym celem jest wprowadzenie i sterowanie 100 kW trójfazowej, dwustopniowej energii fotowoltaicznej do sieci w celu utrzymania stałego napięcia niezależnego od zmian promieniowania słonecznego oraz utrzymania THD prądu zgodnie z międzynarodowymi standardami. Wdrożenie systemu fotowoltaicznego zależy od praktycznych problemów systemowych. Tworzone jest sterowanie mocą bierną i sterowanie falownikiem. Zmienna sieciowa całego systemu wskazuje na dobre wykorzystanie mocy biernej. Sugerowany w tym badaniu system fotowoltaiczny o mocy 100 KW zapewnia regulację mocy biernej i sinusoidalne trójfazowe prądy wyjściowe. Za pomocą oprogramowania MATLAB 2021b i Simulink wyjaśniono skuteczność zalecanego systemu i wykazano jego żywotność. Wyniki wykazały skuteczność zalecanego projektu i modelowania.
PL
W pracy opisano przykład modelowania prototypowego układu regulacji napięcia i mocy biernej zgodnie z rozwiązaniami zawartymi w normach IEC 61850 (PN-EN 61850). Typowe urządzenia stosowane w energetyce oraz funkcje przez nie realizowane (zabezpieczenia, regulatory itp.) zostały ustandaryzowane i ujęte w normach jako kompatybilne klasy węzłów logicznych. Wiele urządzeń, zwłaszcza prototypowych lub stosowanych w mniejszej skali, nie posiada swojej reprezentacji w normach IEC 61850. Autorzy tych układów samodzielnie tworzą modele obiektów danych a następnie własne definicje węzłów logicznych postępując zgodnie z określonymi w normach zasadami. W Polsce takim przykładem są układy regulacji napięcia i mocy biernej dla stacji najwyższych napięć oraz elektrowni (ARST lub ARST/ARNE).
EN
The paper presents the example of modelling prototype voltage and reactive power control device according to the solutions contained in the standards IEC 61850 (PN-EN 61850). Typical devices used in power engineering and their implemented functions (protections, controllers, etc.) have been standardized and defined in the standards as a compatible class of logical nodes. Many devices, especially prototype devices or those used on a lesser scale, do not have their representation in IEC 61850 standards. The authors of these systems create models of data objects independently and next, their own definitions of logical nodes following the rules defined in the standards. In Poland, such examples are voltage and reactive power control systems for the highest voltage substations and power plants (ARST or ARST/ARNE).
PL
Rozwój krajowej struktury wytwarzania energii oraz związanej z nią topologii sieci przesyłowej może skutkować w szczególnych przypadkach problemami z utrzymaniem wymaganych poziomów napięć i zwiększonym zapotrzebowaniem na regulację mocy biernej. Zapotrzebowanie na regulację mocy biernej ma charakter lokalny i wobec ograniczonej liczby potencjalnych dostawców, kontraktacja usługi przez OSP na zasadach konkurencyjnych jest trudna do przeprowadzenia. Jednostki wytwórcze zlokalizowane w KSE mają nieodpłatny obowiązek zapewnienia zdolności do generacji mocy biernej w określonym przepisami zakresie. Płatną usługą jest grupowa regulacja napięcia i mocy biernej w systemie ARNE. Obecny katalog usług regulacyjnych nie przewiduje zachęt ekonomicznych do oferowania zwiększonego w stosunku do wymagań zakresu regulacji mocy biernej. Mając na uwadze powyższe względy w referacie przedstawiono koncepcję wynagradzania za gotowość jednostek wytwórczych do udostępnienia szerszego zakresu regulacji mocy biernej, bazującą na wycenie kosztów związanych z utrzymaniem i eksploatacją majątku produkcyjnego zaangażowanego w świadczenie usługi.
EN
The development of the national energy generation structure (the concentration of wind energy in the northern part of Poland at the location majority of conventional power plants in the central and southern part) and the related topology of the transmission network may result in specific problems with maintaining the required voltage levels and increased demand for reactive power regulation. The planned implementation of projects for the construction of offshore wind farms in the Baltic Sea may deepen the above challenges. The demand for reactive power regulation is local and due to a limited number of potential suppliers that may use their market power, contracting a service by a TSO on a competitive basis is difficult to implement. The generating units located in the National Power System have a free obligation to ensure the capability of reactive power generation in the specified scope. Paid service is group regulation of voltage and reactive power in the ARNE system, provided by centrally available units. The current catalog of regulatory services does not provide for economic incentives to offer increased reactive power control in relation to the requirements. Bearing in mind the above considerations, the paper presents the concept of rewarding for the readiness of generating units to provide a wider range of reactive power regulation, based on the valuation of costs related to the maintenance and operation of the productive assets involved in providing the service.
EN
This paper presents an advanced control of photovoltaic system with battery storage system and shows the coordination of the studied system in order to enhance solar energy utilization. This study proposes an approach of coordinated and integrated control of solar PV generators with battery storage control in order to maintain active and reactive power (P-Q) control and to provide voltage and frequency (V-f) support to the grid instead of a high load addition. The description of the studied system is based on a battery energy storage system based (lithium-ion technology), a DC-DC bidirectional power converter in order to connect the battery to the DC bus, DC-DC converter, voltage source inverter and finally the load and the micro-grid. Consequently, the main contribution of the proposed control methods lies in the coordination between the different controls methods proposed: battery control at the PV side and V-f/P-Q control algorithm at the inverter side. A simulation using the Matlab/Simulink software has been performed, to confirm that the proposed control model is able to provide voltage and frequency support to the grid and to maintain active and reactive power control instead of a high load addition.
PL
Niniejszy artykuł przedstawia zaawansowaną kontrolę systemu fotowoltaicznego z systemem baterii i pokazuje koordynację badanego systemu w celu zwiększenia wykorzystania energii słonecznej. W opracowaniu zaproponowano podejście polegające na skoordynowanym i zintegrowanym sterowaniu generatorami fotowoltaicznymi z kontrolą akumulatorów w celu utrzymania kontroli mocy czynnej i biernej (P-Q) oraz zapewnienia wsparcia napięcia i częstotliwości (V-f) dla sieci zamiast dodawania wysokiego obciążenia. Opis oparty jest na systemie akumulacji energii akumulatora (technologia litowo-jonowa), dwukierunkowym konwerterze mocy DC-DC w celu podłączenia akumulatora do szyny DC, przetwornicy DC-DC, falownika źródła napięcia i wreszcie obciążenie. W związku z tym główny wkład proponowanych metod sterowania polega na koordynacji różnych proponowanych metod sterowania: kontrolą baterii po stronie PV i algorytm sterowania V-f / P-Q po stronie falownika. Przeprowadzono symulację za pomocą oprogramowania Matlab / Simulink, aby potwierdzić, że proponowany model sterowania jest w stanie zapewnić wsparcie napięcia i częstotliwości dla sieci oraz utrzymać kontrolę mocy czynnej i biernej zamiast dodatku o wysokim obciążeniu.
EN
The paper presents results of application of active and reactive power control algorithm at wind and photovoltaic power stations.
PL
Przedstawiono wyniki pomiarów realizacji algorytmu regulacji mocy czynnej i biernej w zastosowaniu do elektrowni wiatrowej i fotowoltaicznej.
PL
Przedstawiono analizę wariantów współpracy układów regulacji farm wiatrowych z układami regulacji napięcia i mocy biernej zainstalowanymi w stacjach elektroenergetycznych i w stacjach przyelektrownianych. Na podstawie wybranych przykładów, symulacji i analiz przedstawiono wytyczne do algorytmów współpracujących i skoordynowanych ze sobą układów regulacji.
EN
Presented is the analysis of various options of cooperation between wind farms control systems and the voltage and reactive power control ones installed in power stations and substations nearby power plants. On the basis of selected examples, simulations and analyses provided are guidelines for algorithms of the cooperating and coordinated with one another control systems.
PL
W artykule przedstawiono wyniki badań pokazujące możliwości wykorzystania baterii kondensatorów zainstalowanych wewnątrz sieci SN (w odbiorców przemysłowych), w celu zminimalizowania strat mocy w sieci elektroenergetycznej. Wyniki analizy pozwoliły określić, które ze stosowanych obecnie kryteriów regulacji jest najbardziej korzystne. Wskazywano również na konieczność koordynacji działań regulatorów transformatora i baterii kondensatorów.
EN
One of the main issues related to the optimization of the MV network is to reduce losses of active and reactive power. Lower losses of active and reactive power give not only economic advantage, but also improvement of energy quality. The object of regulation that can be used for these purposes are transformer with On-Load Tap Changer and capacitor's banks. This paper presents results of analysis of the possibility of using capacitor banks installed inside the MV network (in industrial consumer) in order to minimize power losses in the power network. The results of analysis allowed to determine which of the criteria adjustment: constant voltage or maintain constant values tgφ, in individual buses is better. It was also pointed to the necessity of the coordination between actions of regulators of the transformer and capacitor banks.
EN
The paper presents results of computer simulations aimed at the operating conditions identification of the power system with local wind generation. The voltage conditions and power flows have been identified according to the voltage control modes in a substation and to the reactive power regulation modes of the wind farm. The simulation results made it possible to recommend optimal operating variants for the wind generators in the power network. These alternatives may be used by Distribution System Operators to specify optimal voltage regulation modes of wind power generation.
PL
W artykule przedstawiono wyniki badań symulacyjnych pracy układu sieciowego z przyłączonymi rozproszonymi (lokalnymi) źródłami wytwórczymi (na przykładzie źródła wiatrowego). Dokonano identyfikacji warunków napięciowych oraz rozpływu mocy w układzie zależnie od sposobu regulacji napięcia w stacji transformatorowej zasilającej układ oraz trybu sterowania mocą bierną generowaną przez źródło. W oparciu o uzyskane rezultaty zaproponowano zalecane warianty współpracy źródeł wiatrowych z siecią elektroenergetyczną. Może to posłużyć operatorom sieci dystrybucyjnych do określenia optymalnego sterowania pracą źródeł wiatrowych.
9
Content available remote Hybrid switch for capacitors bank used in reactive power compensation
EN
This paper describes new concept of a switch dedicated for control of three-phase capacitor bank used for low voltage, reactive power compensation. The proposed device utilizes fully controlled IGBT transistors that gives possibility to break capacitor current in moment that ensures zero voltage remaining on capacitor’s terminals. This minimize voltage stress for switch and capacitor as well as allows to turn-on again capacitors bank without unnecessary delay. This paper describes structure of hybrid switch and its operation with capacitor bank and detuning inductor.
PL
Artykuł opisuje nową koncepcję łącznika dedykowanego do załączania banku kondensatorów używanych do kompensacji mocy biernej w sieciach niskiego napięcia. Zaproponowany łącznik wykorzystuje tranzystory IGBT, co umożliwia przerywanie prądu kondensatora w chwili, gdy napięcie na zaciskach kondensatora jest równe zero. Zmniejsza to stres napięciowy łącznika i kondensatora oraz pozwala na ponowne załączenie banku kondensatorów bez zbędnego opóźnienia. Artykuł opisuje strukturę łącznika hybrydowego oraz jego pracę z bankiem kondensatorów i dławikiem wygładzającym.
10
Content available remote Zmodyfikowany układ wytwarzania energii elektrycznej z generatorem synchronicznym
PL
W artykule przedstawiono zmodyfikowany układ generacji energii elektrycznej składający się z generatora synchronicznego i równoległego przekształtnika energoelektronicznego. W zmodyfikowanym układzie generator synchroniczny jest źródłem mocy czynnej a przekształtnik energoelektroniczny dostarcza moc bierną. Zastosowanie przekształtnika energoelektronicznego umożliwia zwiększenie maksymalnej mocy czynnej pozyskiwanej z generatora synchronicznego oraz zwiększa moc pozorną układu. Opracowane sterowanie zmodyfikowanym układem wytwarzania energii elektrycznej zostało zweryfikowane badaniami symulacyjnymi stanów przejściowych.
EN
The paper presents a modified power generation system of a wound rotor synchronous generator equipped in parallel connected power electronic converter. The synchronous generator is a source of active power whereas the power electronic converter delivers reactive power. In such an arrangement the generator is producing more active power that responds apparent power in conventional system. The paper presents the theory of modified generating system, control concept and results of computer simulation related to transient states.
EN
This paper proposes a Takagi-Sugeno neuro-fuzzy inference system for direct torque and stator reactive power control applied to a doubly fed induction motor. The control variables (d-axis and q-axis rotor voltages) are determined through a control system composed by a neuro-fuzzy inference system and a first order Takagi-Sugeno fuzzy logic controller. Experimental results are presented to validate the controller operation for variable speed under no-load and load conditions and stator reactive power variation under load condition. For this last validation, a PI controller is used to control the rotor speed, thereby its output is used to manipulate the torque in order to follow the demanded speed value.
XX
W artykule opisano inferencyjny neuro-fuzzy system Takagi-Sugeno użyty do sterowania momentem i mocą bierną w podwójnie zasilanym silniku indukcyjnym. Przeprowadzono eksperymenty sterowania silnikiem obciążonym i nieobciążonym.
EN
The article describes a control system designed at the Institute of Power Engineering Gdańsk Division, which has been applied in Dunowo substation and nearby wind farms. Control systems use wind farms in the process of voltage and reactive power control. The device structure, rules of control and requirements described in the Instruction of Transmission System Operation and Maintenance (grid code) released by Polskie Sieci Elektroenergetyczne Operator SA the Transmission System Operator in Poland are presented.
PL
W artykule przedstawiono opracowany i zrealizowany przez Instytut Energetyki system regulacji napięć i mocy biernych dla węzła Dunowo, obejmujący stację elektroenergetyczną najwyższych napięć oraz dwie spośród wielu farm wiatrowych. Zaprezentowano aktualne wymagania OSP dotyczące regulacji napięcia z wykorzystaniem farm wiatrowych. Przedstawiono budowę i strukturę systemu, reguły działania jego składników, a także zasady koordynacji regulacji transformatorowej w stacji najwyższych napięć i generatorowej w farmach wiatrowych.
13
EN
In this paper the authors wish to draw attention to the rationale for, and the possibility of, the use of local reactive power sources by the Transmission Node Master Controller (TNMC). Large Customers (LC) are one of the possible reactive power sources. The paper presents the issues related to the need for coordination between the control systems installed in the LC network, and coordination between control systems of the LC as well as master control systems in the network.
PL
Autorzy artykułu zwracają uwagę na celowość i możliwość wykorzystania lokalnych źródeł mocy biernej przez układy regulacji grupowej węzła przesyłowego (RGWP). Jednym z takich źródeł są wielcy odbiorcy (WO). W artykule przedstawiono również zagadnienia związane z potrzebą koordynacji pomiędzy układami regulacji zainstalowanymi w sieci WO oraz koordynacji pomiędzy układami regulacji WO a układami regulacji nadrzędnej w sieci.
PL
W artykule przedstawiono opracowany i zrealizowany przez Instytut Energetyki system regulacji napięć i mocy biernych dla węzła Dunowo obejmujący stację elektroenergetyczną najwyższych napięć oraz dwie, spośród wielu, przyłączone farmy wiatrowe. W treści zaprezentowano aktualne wymagania OSP dotyczące regulacji napięcia z wykorzystaniem farm wiatrowych. Przedstawiono budowę i strukturę wykonanego systemu, zasadę działania jego składników a także zasady koordynacji regulacji transformatorowej w stacji najwyższych napięć i generatorowej w farmach wiatrowych.
EN
Article describes control system designed in Institute of Power Engineering Gdańsk Division, which has been applied in substation Dunowo and nearby wind farms. Control systems uses wind farms in process of voltage and reactive power control. Presented are device structure, rules of control and requirements described in Instruction of Transmission System Operation and Maintenance (grid code) released by the Polish Transmission System Operator.
15
Content available remote A novel method to identify critical Voltage Control Areas
EN
The power system all over the world experience from time to time big failure leading to total lack of voltage over a large area - called blackout. This paper presents an automated method for preventing the voltage collapse. This method called VCA (Voltage Control Area) allows to calculate reactive power necessary to mitigate the grid and point out the weak knots where the reactive power should be injected. This method was applied and tested with Polish transmission network.
PL
Systemy elektroenergetyczne całego świata doświadczane są awariami, które zwykle prowadzą do całkowitego zaniku napięcia tzw. blackout’u. Poniższy artykuł przedstawia automatyczną metodę systemowego zapobiegania utracie stabilności napięciowej. Metoda VCA określa krytyczne obszary regulacji napięcia, tzw. obszary VCAs w systemie (z uwzględnieniem topologii, warunków i ograniczeń przesyłu oraz oblicza wymagane źródła mocy biernej, potrzebne dla zapewnienia bezpieczeństwa. Metoda przeszła pomyślnie wstępne testy dla krajowych sieci przesyłowych.
EN
The paper contains comments on the expedience, feasibility, and potential manner of using reactive power sources for V and Q control in an MV grid. Also indicated is the expedience of quality control verifi cation of 110 kV / MV transformers supplying the grid.
PL
W artykule zawarto uwagi dotyczące celowości, możliwości oraz ewentualnego sposobu wykorzystania źródeł mocy biernej w celu regulacji U i Q w sieci SN. Wskazano również na celowość weryfikacji jakości sterowania transformatorów zasilających sieć 110 kV/SN.
EN
This paper presents examples of coordination between automatic voltage and reactive power control systems (ARST) covering adjacent and strongly related extra high voltage substations. Included are conclusions resulting from the use of these solutions. The Institute of Power Engineering, Gdańsk Division has developed and deployed ARST systems in the national power system for a dozen or so years.
PL
W artykule przedstawiono przykłady koordynacji pracy układów regulacji napięć i mocy biernych (ARST) obejmują- cych sąsiednie, silnie powiązane stacje najwyższych napięć. Zawarto wnioski wynikające ze stosowania tych rozwiązań. Instytut Energetyki Oddział Gdańsk od  kilkunastu lat opracowuje i  wdraża układy ARST w  krajowym systemie elektroenergetycznym.
first rewind previous Strona / 1 next fast forward last