This paper deals with the problems of power supply efficiency for non-traction railway customers. Unlike public distribution networks, the non-traction power supply network is within the zone of influence of electromagnetic fields and the conductive influence of the distorted traction current. As a result, poor power quality and additional losses are typical for non-traction railway networks. Subsequently, conflicts due to the low quality of electricity may arise between the railway and its customers powered by the distribution networks of the railway. The influence of a reactive power compensation device on the voltage drop in a non-traction power line is investigated in the article. The implementation of reactive power compensation allows voltage losses during its transmission to the final consumer to be reduced by almost 5% and electricity losses by 3%.
EN
The iterative control of the power electronic compensator is presented. The method is based on the voltage measurement. The single phase DC/AC inverter with PWM control is considered. The inverter generates the reactive current shifted to voltage. The current amplitude is computed with the use the iterative algorithm based on Euler secant method. The required voltage amplitude is chosen as the objective function and the limits of the compensator current constitute the constraints. The simulation results for the circuit composed of the simple grid model and DC/AC inverter is presented. The DC/AC inverter with the series inductor realize the current source. The simulation are done with the use PLECS program. Sliding DFT seems to be adequate to compute the correct shift angle between voltage fundamental harmonic and compensator current. The simulation shows that the capacitor voltage connected at the DC side of inverter can be maintained by choosing of the power angle between the grid voltage and inverter voltage.
PL
Przedstawiono koncepcję iteracyjnego sterowania układu wytwarzającego prąd bierny. Metoda opiera się na pomiarze napięcia sieci w węźle przyłączenia kompensatora. Rozpatrywany jest jednofazowy przekształtnik DC/AC ze sterowaniem PWM, realizujący sterowane źródło prądu sinusoidalnego przesuniętego względem pierwszej harmonicznej napięcia sieci. Amplituda wytwarzanego prądu jest obliczana z wykorzystaniem algorytmu iteracyjnego. Funkcją celu w tym algorytmie jest zadana wartość amplitudy podstawowej harmonicznej napięcia sieci. Zmienną poszukiwaną w procesie optymalizacji jest rzeczywisty współczynnik równy stosunkowi amplitudy generowanego sinusoidalnego prądu kompensatora do zmierzonej amplitudy podstawowej harmonicznej napięcia sieci. Pokazano możliwość wytworzenia sygnału sterującego przekształtnik AC/DC w kilku krokach metody iteracyjnej. Metodę tą można zakwalifikować do metod siecznych Eulera. Zaprezentowano wyniki symulacji komputerowych układu złożonego z uproszczonego modelu obwodowego sieci, przekształtnika DC/AC ze sterowaniem PWM oraz szeregowo włączoną cewką indukcyjną. Cewka indukcyjna umożliwia realizację źródła prądu i obliczenie sygnału sterującego przekształtnik. Symulacje wykonano z wykorzystaniem języka programowania PLECS. Pokazano możliwości podtrzymywania napięcia kondensatora włączonego po stronie DC przekształtnika za pomocą kąta mocy między napięciem sieci i napięciem przekształtnika.
EN
The paper presents a concept of a control system for a high-frequency three-phase PWM grid-tied converter (3x400 V / 50 Hz) that performs functions of a 10-kW DC power supply with voltage range of 600÷800 V and of a reactive power compensator. Simulation tests (in PLECS) allowed proper selection of semiconductor switches between fast IGBTs and silicon carbide MOSFETs. As the main criterion minimum amount of power losses in semiconductor devices was adopted. Switching frequency of at least 40 kHz was used with the aim of minimizing size of passive filters (chokes, capacitors) both on the AC side and on the DC side. Simulation results have been confirmed in experimental studies of the PWM converter, the power factor of which (inductive and capacitive) could be regulated in range from 0.7 to 1.0 with THDi of line currents below 5% and energy efficiency of approximately 98.5%. The control system was implemented in Texas Instruments TMS320F28377S microcontroller.
PL
W artykule przedstawiono zagadnienia związane z wykorzystaniem generatorów synchronicznych, pracujących w układach kogeneracyjnych, w nadążnym układzie kompensacji mocy biernej. Przeprowadzono analizę wpływu podłączenia generatorów synchronicznych na opłaty za energię elektryczną oraz pokazano możliwość regulacji mocy biernej generatora. Omówiono również system nadążnej kompensacji mocy biernej Progress CUK.
EN
The article presents the aspects of using synchronous generators operating in a CHP system in a reactive power compensation follow-up system. An analysis of connecting the synchronous generators to a supply system and their impact on electrical energy charges is shown as well as the possibility of adjusting the reactive power of the generator. The author also discusses the ProgressCUK® follow-up control system for reactive power compensation.
5
Content available remote Zastosowanie wielokomórkowego regulatora AC/AC do kompensacji mocy biernej
PL
W artykule dokonano analizy możliwości wykorzystania wielokomórkowego regulatora AC/AC jako kompensatora mocy biernej. Przedstawiono aktualne zastosowanie wielokomórkowego regulatora napięcia przemiennego. Wyznaczono zależności analityczne określające wartość mocy biernej generowanej przez wielokomórkowy regulator napięcia obciążony indukcyjnością. Zaprezentowano wyniki badań symulacyjnych wielokomórkowego kompensatora mocy biernej podstawowej harmonicznej prądu sieci.
EN
The article presents the analysis of possibility of use a multicell AC/AC voltage regulator as reactive power compensator. The current possibility of use of multicell AC/AC converter was also present as well as the dependences defining reactive power of multicell AC voltage regulator. The results of simulating of multicell reactive power compensator were presented. The proposed use of AC/AC multicell voltage regulator extend possibility of use of multicell converters.
EN
The problem of the control of reactive power compensators in multilevel industry power grid is analysed in the paper. The minimisation of active power losses caused by reactive power flows in the grid is taken as the main criterion of optimisation. Additional criterions and restrictions resulting from maintenance of the power factor in desired limits, different voltage levels in grid nodes, limited range of reactive power of compensators, discrete (step) operation of some compensators, capacitors banks for example, are taken into account in the control algorithm. Chosen results of the simulation research and obtained in industrial control system are presented in the paper.
PL
W artykule przedstawiono problem kompensacji mocy biernej w sieci przemysłowej. Jako główne kryterium optymalizacyjne przyjęto minimalizację strat mocy czynnej spowodowanych przepływem mocy biernej. Uwzględniono również dodatkowe kryteria i ograniczenia, jak: utrzymanie współczynnika mocy w punkcie zasilania w zadanym zakresie, różne wartości napięć w węzłach sieci, skończone zakresy regulacji mocy biernej kompensatorów, dyskretne wartości mocy biernej niektórych kompensatorów, np. baterii kondensatorów. Zaprezentowano wybrane wyniki badań symulacyjnych oraz pomiary uzyskane w przemysłowym systemie kompensacji mocy biernej.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.