Preferencje help
Widoczny [Schowaj] Abstrakt
Liczba wyników

Znaleziono wyników: 4

Liczba wyników na stronie
first rewind previous Strona / 1 next fast forward last
Wyniki wyszukiwania
Wyszukiwano:
w słowach kluczowych:  reżim przepływu
help Sortuj według:

help Ogranicz wyniki do:
first rewind previous Strona / 1 next fast forward last
EN
Multiphase flow meters are used to measure the water-liquid ratio (WLR) and void fraction in a multiphase fluid stream pipeline. In the present study, a system of multiphase flow measurement has been designed by application of three thallium-doped sodium iodide scintillators and a radioactive source of 133Ba simulated by Monte Carlo N-particle (MCNP) transport code. In order to capture radiations passing across the pipe, two direct detectors have been installed on opposite sides of the radioactive source. Another detector has been placed perpendicular to the transmission beam emitted from the 133Ba source to receive radiations scattered from the fluid flow. Simulation was done by the MCNP code for different volumetric fractions of water, oil, and gas phases for two types of flow regimes, namely, homogeneous and annular; training and validation data have been provided for the artificial neural network (ANN) to develop a computation model for pattern recognition. Depending on applications of the neural system, several structures of ANNs are used in the current paper to model the flow measurement relations, while the detector outputs are considered as the input parameters of the neural networks. The first, second, and third structures benefit from two, three, and five multilayer perceptron neural networks, respectively. Increasing the number of ANNs makes the system more complicated and decreases the available data; however, it increases the accuracy of estimation of WLR and gas void fraction. According to the results, the maximum relative difference was observed in the scattering detector. It was clear that transmission detectors would demonstrate the difference between the flow regimes as well. It is necessary to note that the error calculated by the MCNP simulator is <0.5% for the direct detectors (TR1 and TR2). Due to the difference between the data of the two flow regimes and the errors of data in the simulation codes of the MCNP, it was possible to separate these flow regimes. The effect of changing WLR on the efficiency for a constant void fraction confi rms a considerable variance in the results of annular and homogeneous flow s occurring in the scattering detector. There is a similar trend for the void fraction; hence, one can easily distinguish changes in efficiency due to the WLR. Analysis of the simulation results revealed that in the proposed structure of the multiphase flow meter and the computation model used for simulation, the two flow regimes are simply distinguishable.
PL
Bakterie z rodzaju Legionella są często wykrywane w systemach dystrybucji wody, zwłaszcza w instalacjach ciepłej wody. Występowaniu tych bakterii sprzyjają między innymi: zbyt niska temperatura wody ciepłej, obecność osadu, korozja, biofilm, zastoiny wody. Systematyczna kontrola temperatury wody w punktach kontrolnych (np.: podgrzewacz wody, cyrkulacja, reprezentatywne punkty czerpalne) w systemach dystrybucji wody zimnej i ciepłej w budynkach oraz reżim przepływu wody powinny być stałymi elementami zarządzania instalacjami. Utrzymywanie odpowiedniej temperatury wody ciepłej (> 50°C) i wody zimnej (< 20°C) oraz regularne płukanie pryszniców/kranów powinny być działaniami wspomagającymi procesy dezynfekcji oraz mającymi na celu ograniczenie występowania warunków korzystnych dla bakterii Legionella.
EN
Bacteria of Legionella genus are often detected in domestic water systems, especially in the hot water system. The low temperature of hot water, presence of sludge, corrosion, biofilm and stagnation of water promote the presence of these bacteria. Systematic control of water temperature at control points (f. e.: water heater, circulation, representative points of use) in water distribution systems and flow regime should be a fixed part of domestic water systems management. Maintaining a suitable hightemperature of hot water (> 50°C) and low temperature of cold water (< 20°C) and regular shower / taps flushing should be supportive measures of disinfection process aimed at reducing the occurrence of favorableconditions for Legionella bacteria.
EN
The article describes the impact of fluctuations in climatic factors on hydrological processes. The analysis of climate and hydrology covers two periods, the first up to 1996 and the second from 1981 to 2012. Study object includes 22 river basins situated on the eastern coast of the Baltic Sea: 1000 km2, up to 10 000 km2 and bigger. The study involved Mann–Kendall, Spearman's and linear regression tests. Causal relationships, as criteria that may fundamentally change the runoff regime set up by climatic factors, were established by evaluating the size of the river basin and assessing the spread of sediments, lakes, swamps and forests in the river basin. The analysis of data from the last thirty years disclosed that, with reference to the previously obtained information, floods in lakes became substantially reduced. Nevertheless, within the winter period of recent years, temperatures prevented lakes from acting as water reservoirs. The paper examined and defined the impact of sediments on variations in the runoff regime. For the period of the last thirty years, cut-off dates, i.e. flood start, crest and end, have advanced.
PL
Przedmiotem artykułu jest wpływ czynników klimatycznych na zmianę procesów hydrologicznych. Dokonano analizy klimatycznej i hydrologicznej dwóch okresów: do roku 1996 i od roku 1981 do 2012. Obiektem badań były zlewnie 22 rzek we wschodniej części wybrzeża Morza Bałtyckiego: do 1000 km2, do 10 000 km2 i większe. W badaniach stosowano testy statystyczne Manna–Kendalla, Spearmana i regresji liniowej przeznaczone do ustalenia związku przyczynowego w ocenie wielkości zlewni rzeki, osadów, jezior, bagien, zalesienia w zlewni rzeki jako kryteria, które w zasadniczy sposób mogą zmienić reżim odpływu ukształtowany przez czynniki klimatyczne. Analiza danych pochodzących z ostatnich trzydziestu lat wykazała, że według wcześniejszych danych jeziora w większym stopniu ograniczały występowanie powodzi, jednak w ostatnich latach temperatura w sezonie zimowym nie pozwala jeziorom pełnić funkcji akumulatorów wodnych. Zanalizowano i określono wpływ osadów na zmiany reżimu przepływu. Stwierdzono, że w ciągu ostatnich trzydziestu lat graniczne daty powodzi – początek, szczyt i koniec – notowane są wcześniej.
PL
Artykuł przedstawia metodę wyznaczania charakterystyki instalacji transportu pneumatycznego materiałów sypkich przy zastosowaniu dwupłaszczyznowego systemu tomografii pojemnościowej. Celem jest uzyskanie informacji niezbędnej do wypracowania prawidłowego sterowania, monitorowania i diagnozowania instalacji przemysłowej. W przypadku systemu transportu pneumatycznego celem jest m.in. zapobieganie blokowaniu rurociągu oraz niszczeniu materiału, na skutek źle dobranych parametrów transportu. Informacja diagnostyczna uzyskana przy użyciu ECT pozwala na skuteczne sterowanie procesem. Polega ono na doborze prędkości i ciśnienia medium transportowego, w celu uzyskania odpowiedniego dla danego materiału typu przepływu. Zostaną przedstawione wyniki tomograficznych pomiarów przepływu dla różnych nastaw falowników sterujących dmuchawą powietrza i rotora podajnika materiału. Na tej podstawie buduje się charakterystykę stanów pracy instalacji transportu pneumatycznego przy określonej prędkości gazu i wydajności przepływu masy. Zebrane wyniki wykorzystane będą przy sterowaniu instalacją transportu pneumatycznego.
EN
This paper reveals a methodology of determination of the bulk solids pneumatic transport installation properties using twin plane electrical capacitance tomography system. The focus is to obtain information necessary for development of proper monitoring, diagnose and control of industrial installation. In case of pneumatic conveying the ultimate goal is to prevent pipeline blockage and material degradation as a result of misadjusted transportation parameters. Diagnostic information coming from ECT allows the effective process control. This consists in velocity and pressure settings, in order to get the appropriate, for given medium, flow regime. In this paper there are flow results for different settings of choppers controlling the air blowjets and rotating feeder. On this basis, the work states characteristics of the pneumatic installation will be constructed.
first rewind previous Strona / 1 next fast forward last
JavaScript jest wyłączony w Twojej przeglądarce internetowej. Włącz go, a następnie odśwież stronę, aby móc w pełni z niej korzystać.